Sei sulla pagina 1di 4

HYDROTECH ENTERPRISES PRIVATE LTD Tel: 011-42240075

E-mail : hydrotechenterprises@gmail.com
706,ITL Twin Towers,B-09,Netaji Subhash Place hydrotechent@sify.com
Pitam Pura Delhi (India)

TECHNICAL DATA SHEET FOR DG SETS


CONTRACT NO:ICB BID No.WRMSP/ICB-02
FURKAT-1 PUMPING STATION
1 DG SET
Manufacturer ADI AUTOMOTIVE PVT.LTD
Engine MAXXFORCE:MAHINDRA NAVISTAR DIESEL ENGINE
Alternator KIRLOSKAR
Quantity Furkat-1: 1 Set
2 Engine Specifications
Model 6.12TCA
Rated Output (Prime rating as per ISO 3046) 146.5KW/199hp
Stanby Output 160KW/217.5hp
Tolerance on rated output power ±5%
No.of Cylinder 6
Bore x Stroke 105 x 137 (mm)
Aspiration TCA
Type of Construction Inline
Displacement 7.12Ltrs
Method of Starting Engine 24V DC
Brake Mean Effective Pressure(bmep) 16.4/18 bar(Rated/Maximum)
Firing Order 1-5-3-6-2-4
Rated RPM 1500
Engine Noise Level <75dBA for genset with canopy
3 Alternator Specifications
Model No H Series
Rating 160 KVA/128KW @ 0.8PF
Insulation Class-Armature H
Protection IP23
Terminal Voltage & Frequency 400Volts, 50Hz
Time permitted to build up rated voltage 0.5Seconds
Permissible Voltage Dip 0.10
Inertia Time Constant 0.3
Bearing type 6310 C3 ZZ
Short Circuit Withstand Time 3 Sec
Overload Withstand Capacity(min. 150% for 15
sec) 150% of rated load for 15 Seconds
Alternator Efficiency at 100%MCR & rated PF 0.928
Alternator Efficiency at 75%MCR & rated PF 0.917
Alternator Efficiency at 50%MCR & rated PF 0.902
Neutral Earthing Yes
Cooling System
Cooling System of Alternator Air
Cooling medium of temperature Air
Temp. rise of armature winding 125⁰C
Temp. rise of Field winding 125⁰C
Heating time Constant 45 Mins
Cooling time Constant 135 Mins
Altitude 1000Mtrs
Ambient Temperature 43⁰C
Employer Ministry of Agriculture & Water Resources, Republic of Uzbekistan.
Project Pumping Station:Furkat-1
Main Contractor Kubota - Ortex Consortium ( Japan - UK)
Sub Contractor Hydro-Tech Enterprises Pvt.Ltd.
Project: Pumping Stations:Furkat-1 Prepared by: PSS App.by:SCK Date: 01.07.2013
Datasheet No:OA-1/13/DG/DS-01 Rev:00 Checked by: RK Sheet No. 1of 3
HYDROTECH ENTERPRISES PRIVATE LTD Tel: 011-42240075
E-mail : hydrotechenterprises@gmail.com
706,ITL Twin Towers,B-09,Netaji Subhash Place hydrotechent@sify.com
Pitam Pura Delhi (India)

TECHNICAL DATA SHEET FOR DG SETS


CONTRACT NO:ICB BID No.WRMSP/ICB-02
FURKAT-1 PUMPING STATION
4 Electrical System
Max. Continuous & Momentary unbalanced load
capacity 25% of rated condition
Open Circuit transient time Constant 0.02
Short Circuit ratio 0.4
5 Exciter
Type of Excitation Self
Range of stabilization 0.01
Capacity in KW 1.84KW
Operating Voltage & Current 70.0 Volts & 2.85 Amps
Duration of Field Forcing Continuous
Class of Insulation H
6 AVR
Type Fast Response Electronic Type
Mounting Inside Terminal Box
Voltage Regulation ±1%
Response time Max 95 Volts DC
7 COOLING SYSTEM
Method of Jacket Cooling Radiator
Heat Removal By Water
Dimensions of radiator(L x H x W) 831 x 390.5 x 1135 (mm)
Qty of Coolant(Engine + Radiator) 25Ltrs
Air flow at Radiator outlet 11800CFM
Fan Power 7KW
8 FUEL SYSTEM
Fuel Injection pump Make: Stanadyne Type: Rotary
Governor Type:Mechanical (3-5%)
Response time(As per IS10002)
Recovery time(As per IS10002)
Fuel Oil Diesel
Fuel Filter Type Spin-on type with paper element
Filtration Capacity 5microns
Filter Change Period 500hours
Specific Fuel Consumption at
100% Load 197/145.0 (g/KW-h / g/hp-h)
75% Load 197/145.0 (g/KW-h / g/hp-h)
50% Load 207/152.4 (g/KW-h / g/hp-h)
Tolerance on SFC 5%
Fuel Consumption at
100% Load 34.15 Ltrs/h
75% Load 25.61 Ltrs/h
50% Load 17.94 Ltrs/h

Employer Ministry of Agriculture & Water Resources, Republic of Uzbekistan.


Project Pumping Station:Furkat-1
Main Contractor Kubota - Ortex Consortium ( Japan - UK)
Sub Contractor Hydro-Tech Enterprises Pvt.Ltd.
Project: Pumping Stations:Furkat-1 Prepared by: PSS App.by:SCK Date: 01.07.2013

Datasheet No:OA-1/13/DG/DS-01 Rev:00 Checked by: RK Sheet No. 2 of 3


HYDROTECH ENTERPRISES PRIVATE LTD Tel: 011-42240075
E-mail : hydrotechenterprises@gmail.com
706,ITL Twin Towers,B-09,Netaji Subhash Place hydrotechent@sify.com
Pitam Pura Delhi (India)

TECHNICAL DATA SHEET FOR DG SETS


CONTRACT NO:ICB BID No.WRMSP/ICB-02
FURKAT-1 PUMPING STATION
9 LUBE OIL SYSTEM
Lube Oil Consumption at 100% Load 0.017Ltrs/hr
Recommended Lube Oil 15W40 API CH4/CI4
Lube Oil Filter Type Full flow: Spin on cartridge type with paper
Filtration Capacity 15microns
Lube Oil change Period 500 Hours
Maximum Lube Oil Temperature ─10⁰C to 125⁰C
Lube Oil Pressure
Must be greater than 1.2Kg/cm2 at idling condition & 3.5Kg/cm2 at rated
speed
Lube Oil System Capacity 19.8Ltrs
10 Exhaust System
Exhaust Silencer Type Residential Type
Exhaust Noise Level(with Silencer) @ 3M Complies with CPCB norms
Max.Permissible Back Pressure in Exhaust 75mm of Hg
Exhaust Gas Flow 664Kg/hr
Exhaust Gas Temperature(Max.) 600⁰C
11 Air Intake System
Intake Filter Type Dry Type Air Cleaner
Air Intake restriction-with clean element 230 mm of H2O
Air Intake restriction-with dirty element 600 mm of H2O
Filtration Capacity 20microns
Maximum Intake manifold Temperature 55⁰C
Combustion Air Inlet flow rate 637Kg/hr
12 Dimensions & Weight Details
L x W x H (With Radiator) 1727 x 932 x 1274.4 (mm)
Dry engine weight -with flywheel & flywheel
housing 598.6Kg
Weight to Power ratio 4.67Kg/KW

Employer Ministry of Agriculture & Water Resources, Republic of Uzbekistan.


Project Pumping Station:Furkat-1
Main Contractor Kubota - Ortex Consortium ( Japan - UK)
Sub Contractor Hydro-Tech Enterprises Pvt.Ltd.
Project: Pumping Stations:Furkat-1 Prepared by: PSS App.by:SCK Date: 01.07.2013
Datasheet No:OA-1/13/DG/DS-01 Rev:00 Checked by: RK Sheet No. 3 of 3