SCP-EX pressure sensors

Device features

Pressure and temperature sensors


„ Measuring range 0 to 1000 bar
„ ATEX approval for zone 1
ƒ II 2G Ex ia IIC T4
„ Output signal 4 to 20 mA
„ Outstanding reliability

The SCP-EX can be configured for Zone 0 and Zone 1. Safety notice
It corresponds to the directive 94/9/EC. In the event of a Be sure to follow the applicable national safety regulations
fault, appropriate circuitry ensures reverse polarity protec- when assembling, commissioning and operating these
tion, over-voltage protection and power dissipation limi- pressure transducers.
tation. The sturdy, compact design and the high level of
precision ensure a wide range of application possibilities.
Application examples
We offer a variety of pressure transducers with combina-
tions of different mechanical and electrical connections. „ Chemical industry
„ Oil and gas industry
Zone 1: where explosive atmospheres as a mixture of air
„ Food and beverage products
and combustible materials, gases, vapours or clouds can
„ Plant construction and automation technology
occur occasionally during normal operation.

23 Catalogue 4083-3/UK
SCP-EX pressure sensors
Technical data
Pressure and temperature sensors

SCP EX- 1.0 1.6 2.5 004 006 010 016 025 040 060 100 160 250 400 600 1.000
Pressure range Pn
1.0 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600 1000
relative 0... (bar)
Overload pressure*
6 6 10 10 20 20 40 100 100 200 200 400 750 750 840 1200
Pmax relative (bar)
Burst pressure**
9 9 15 15 30 30 60 150 150 300 300 600 1000 1000 1050 1500
Pburst relative (bar)
* DIN EN 60770-1
** DIN 16086

Process connection Ambient conditions


G1/4A BSPP; DIN 3852 T11, Form E; ED seal FKM Ambient temperature range -40 to +85 °C
Material Compensated range -20 to +85 °C
Parts in contact with sub- Stainless steel Storage temperature -40 to +125 °C
stances Vibration resistance 20 g according to IEC 68-2-6
Housing Stainless steel and IEC 68-2-36
Accuracy Temperature coefficient ” ± 0.2 % FS/10 K
Including non-linearity, ” 0.5 % FS Shock resistance 1000 g according to
hysteresis, repeatability, IEC 68-2-32
zero-point and full-scale
deviations (IEC 61298-2)
BFSL ” Pin assignment
ATEX approval, zone 1, EM compatibility
Device plug DIN EN 175301-803 Form A
Ignition protection II 2G Ex ia IIC T4
category 4-pole (old 43650)
Underlying standard EN 60079-0, EN 60079-11, EN SCP-xxx-3x-06-EX1
60079-26, EN 60079-14
PIN Assignment
Max. value of connection 27 V; 125 mA; 85 W
1 V+
Temperature class T4 (surroundings -40 to +85 °C)
2 P signal
CE EC Directive 94/9/EC
3 n.c.
General
n.c.
Response time ”1 ms
Long-term stability < 0.2 % FS/a Protection class IP65
Weight 150 g

Output signal 4 to 20 mA (2-wire)


Auxiliary power V+ +20…27 VDC
Max. load < (V+ - 16 V) / 20 mA
minimum 100 Ω

24 Catalogue 4083-3/UK
SCP-EX pressure sensors
Pin assignment Dimensioned drawings

Pressure and temperature sensors


Circular connector M12x1 4-pole SCP-xxx-35-0x-EX1
SCP-xxx-3x-07-EX1 1/4 NPT

PIN Assignment
1 V+
2 n.c.
3 P signal
4 n.c.
Protection class IP65
SCP-xxx-34-0x-EX1
G1/4 BSPP
Dimensioned drawings
SCP-xxx-3x-06-EX1
Device connector DIN EN 175301-803 Form A
4-pole (old 43650)

X1)= ED seal

Order code
Pressure sensor SCP-EX SCP-xxx-3x-0x-EX1

Pressure range (bar)*


1.0 –––––––––––––––––––––––––––––––––––––– 001
1.6 –––––––––––––––––––––––––––––––––––––– 01.6
2.5 –––––––––––––––––––––––––––––––––––––– 02.5
4 ––––––––––––––––––––––––––––––––––––––– 004
6 ––––––––––––––––––––––––––––––––––––––– 006
10 –––––––––––––––––––––––––––––––––––––– 010
16 –––––––––––––––––––––––––––––––––––––– 016
25 –––––––––––––––––––––––––––––––––––––– 025
40 –––––––––––––––––––––––––––––––––––––– 040
SCP-xxx-3x-07-EX1 60 –––––––––––––––––––––––––––––––––––––– 060
100 ––––––––––––––––––––––––––––––––––––– 100
Circular connector M12x1; 4-pole
160 ––––––––––––––––––––––––––––––––––––– 160
250 ––––––––––––––––––––––––––––––––––––– 250
400 ––––––––––––––––––––––––––––––––––––– 400
600 ––––––––––––––––––––––––––––––––––––– 600
1000 ––––––––––––––––––––––––––––––––––––1000

* Refer to page 102 "Pressure range selection"

Process connection
G1/4 BSPP –––––––––––––––––––––––––––––––––––4
1/4 NPT (Pn max. = 600 bar) –––––––––––––––––––––5

Connecting plug
Circular connector M12x1 4-pole ––––––––––––––––––– 7
Device connector DIN EN 175301-803 Form A 4-pole – 6
S1) = 22

25 Catalogue 4083-3/UK