Sei sulla pagina 1di 2

E9000 Server Power Report

Server Configuration
* Chassis E9000
* Fan Module X 14
TPS2500-12D 2500W
* PSU X 6
Blade Server Config Platinum(02310LHN)
Management Module MM910(03054675) X 2
Switch/Pass-Thu Module CX110(03021SLP) X 2
Switch/Pass-Thu Module CX912(03056858 ) X 2
* Node E9000 CH121 V3 X 7
E5-2658 V4 2.3Ghz 14
* CPU X 2
Core(41020550)
16G 2Rx8 PC4-
* Memory X 12
Node(0) 2400T(02311TEE)
Configuration 2.5''-1200GB-SATA
Front Disk 6.0Gb/s MLC X 2
NAND(02311JDB)
MZ310-
Mezz Card X 2
2*10GE(03022YMY)

Power Trend Info


Support Voltage :48 V/DC
CO2
System BTU
Load(%) Input Power(W) Input Current(A) Hour(BTU/hour) Load Power(W) Emissions(kg/ho
ur)
100 3071.11 63.98 10479.02 2842.31 3.06
90 2852.96 59.44 9734.67 2640.41 2.84
80 2652.88 55.27 9051.97 2455.24 2.64
70 2439.75 50.83 8324.74 2257.99 2.43
60 2239.67 46.66 7642.04 2072.81 2.23
50 2020.02 42.08 6892.57 1869.52 2.01
40 1819.93 37.92 6209.83 1684.35 1.81
30 1671.88 34.83 5704.67 1499.17 1.67
20 1465.37 30.53 5000.03 1314.00 1.46
10 1248.62 26.01 4260.45 1119.64 1.24
0 939.69 19.58 3206.34 842.62 0.94

Disclaimer
The power data provided by Huawei Server Power Calculator is based on hardware
measurements under typical operating conditions.
Workload differences greatly affect power consumption, even with the same CPU
utilization. The calculation model cannot account for every variation in environmental and
data center factors, and therefore provides only reasonable estimates.
Huawei acknowledges deviations in actual situations and does not claim or guarantee
the absolute accuracy of the data provided. Users should calibrate the data with
measurements of actual workloads.
Calibrate your data with actual workload measurements.