Slide 2
Rango de Motores @ 60 Hz
Slide 3
50 Hz Motor Range
Slide 4
Aplicación de Motores Reda
Slide 5
Proceso de Selección
Slide 6
Pasos en la Selección
Slide 7
Serie del Motor
Slide 8
Serie del Motor
Slide 9
Tipo de Motor — Nomenclatura
Slide 10
Tipo de Motor — Clasificación
El tipo de motor se designa con dos letras:
La primera letra es un código el cual provee información
relacionada con la CLASIFICACION del MOTOR:
S = Estándard (250°F BHT – potencia fija),
M = Intermedia (300°F BHT – potencia fijada
conservadoramente)
H = Hotline (450°F Temperatura del Devanado del Motor –
potencia fija)
P = Alto Rendimiento (250°F BHT – potencia fijada
conservadoramente)
R = Optimo (400 °F Temperatura Interna – potencia
Slide 11 variable)
Tipo de Motor — Aislamiento
Slide 12
Nomenclatura Antigua
Slide 13
Aplicación de Motores Reda
Slide 14
Motores MK y MX
Slide 15
Cojinetes
Slide 16
Configuración, Voltaje & Amperaje
Slide 17
Aplicación de Motores Reda
Slide 18
Aplicación de Motores Reda
Slide 19
Aplicación de Motores Reda
III. CONFIGURACION DEL MOTOR, VOLTAJE & AMPERAJE,
Slide 21
Aplicación de Motores Reda
Slide 22
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
This explains why the various voltages -- but why such
odd voltages?
Surface motors, for example, are rated at 460V, 4160V,
2300V, etc.
These motors are made to "standard voltages". So
why do the REDA motor voltages turn out to be such
strange numbers?
Slide 23
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
In a way we have already answered this. The problem
is the voltage drop in the cable. SPS motors have to
contend with a very long length of power cable which
surface motors do not.
If we have a 460V surface supply, we would probably
only want about 430V downhole (for a low Hp motor) to
give us the necessary 460V at the surface including
the cable loss.
Slide 24
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE & AMPERAGE,
So in determining motor voltages we are really limited by
surface equipment.
Motor control panels come in certain voltage ranges
such as 600V, 1000V, 1500V, 2400V, etc.
Slide 25
Aplicación de Motores Reda
Slide 26
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
In reality, there are dozens of potential winding
configurations for any particular motor Hp but the
number is intentionally limited to three or four to try to
cover the majority of applications with the minimum
amount of inventory.
Occasionally an application requires a special winding
and engineering should be consulted to see if it is
possible -- not every voltage can be hit exactly.
Slide 27
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
Slide 28
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
Slide 32
Aplicación de Motores Reda
III. MOTOR CONFIGURATION, VOLTAGE &
AMPERAGE,
With two motors we double the Hp (add the two Hp's
together). We also double the voltage but the
amperage remains the same.
Slide 33
Aplicación de Motores Reda