Sei sulla pagina 1di 3

Hydraulic Design

Name of road Suthaliya- Narsingarh Road to Gujarkhedi

Ch : Package ;- 2640

1 Parameters Remarks

Chainage = m

Lowest Bed Level (LBL) = 110.540 m

H.F.L. = 112.920 m

Difference in L.B.L. & HFL = 2.380 m

Catchment Area (M) = 16.900 sqkm

Bed Width = 25.00 m

Bank Width = 80.0 m

R.T.L. = 111.770 m

2 Calculation of Run Off

(i) By Dicken's Formula :-

Q = C*( M )3/4 (As per SP-13 Pg. No. -13)

Q = 14(12.70)3/4 = 116.69 cumecs

(ii) By Manning's Formula :-

R2/3.S1/2 Where V= Velocity in m/sec.


V=
n R = Hydraulic mean depth
S = Energy Slope which may be
taken equal to bed slope

R = Rugosity Cofficient

n = 0.033 ( As per SP -13 Clause


5.4, Pg No. -34)
A = Area
A= 70.0 sqm
P= Wetted perimeter
A 70.0
R= =
P 46.0
= 1.52 M

2.01
S= = 0.010
200

R2/3.S1/2 1.522/3 × 0.0101/2


V= =
n 0.033

= 4.019 M/s

3 Design Discharge Q = A × V = 70 × 4.019

Q= 281.34 cumecs

Vent Area (A) = Bed width (RTL - Lowest Bed level )

= 25 × (111.77-110.54)

= 30.750 sqm

After Slab design vent area (a) = No. of Slab × Span × (Diff. of HFL - LBL)

= 4 × 6 × (112.92-110.54)

= 57.120 sqm
Discharge through After Slab Design q=
= 60.84 × 3.50 Velocity V= 3.50 in m/sec.
A×V
= 199.920 cumecs

Remaining discharge = Q-q

= 281.34 - 199.92

= 81.417 cumecs

Area of over topping = 70 × 0.40

= 28.00

Discharge through over topping = 28 × 3.5

= 98.00

Compare 81.417 < 98.000

Hence Safe