Front Single Axles and Rear Tridem Axles not considered for bottom-up analysis.
Doweled joint and Tied Concrete Shoulders Slab Thickness (m) = 0.3
M/s. Rajaram Construction
CALCULATION OF HYDRAULIC DISCHARGE AND DESIGN OF OPENING
1. Chainage of C.D.
2. Description of catchments 0.2 Sq Km. or Acre 49.40
3. Height of fill permitted 0.6 Mtr. Hectares 20
4. Pipe Diameter proposed 1 Mtr. No 3
Q= CM3/4
= 17 * (0.2) 3/4
= 5.084186 cum/sec
No of pipe required
As Per This Design
Water way required = 5.084186 / v = 2.000 Sqm
1. Chainage of C.D.
2. Description of catchments 0.08 Sq Km. or Acre 19.76
3. Height of fill permitted 0.06 Mtr. Hectares 8
4. Pipe Diameter proposed 1 Mtr. No 2
Q= CM3/4
= 17 * (0.08) 3/4
= 2.55721 cum/sec
No of pipe required
As Per This Design
Water way required = 2.55721 / v = 1.006 Sqm
1. Chainage of C.D.
2. Description of catchments 0.06 Sq Km. or Acre 14.82
3. Height of fill permitted 0.06 Mtr. Hectares 6
4. Pipe Diameter proposed 1 Mtr. No 1
Q= CM3/4
= 17 * (0.06) 3/4
= 2.060926 cum/sec
No of pipe required
As Per This Design
Water way required = 2.060926 / v = 0.8107 Sqm
Hydraulic Calculation
1. Location = 7940
2. Constant 'C' = 16.00
3. Catchment Area 'M' = 0.645 SqKm
4. HFL = 82.86 m
5. Bed Level =81.395 m
6. Hydraulic mean depth "R" = 0.81
7. Slop of Nala =0.010
8. Regocity Coeficient of 'n' =0.035
= 20.93 CUMEC
Abopt Max discharge for calculated by MANNING's FORMULA
The Linear Water Way