Energy Saving
The iFan, demand controlled solution, reduces
ventilation running costs, energy consumption,
maintenance and noise.
Increased Safety
The iFan control system runs on low voltage SELV
(Safety Extra Low Voltage) improving the safety of
installers and users.
Simplified Installation
The iFan sensors and switches are supplied with 10m of
cable, a flexible gland terminated with a plug, simplifying
and reducing the time and cost of safe installation.
Single Source
All iFans are stand alone, and fully functional, ensuring
operational responsibility is via one source.
Diagnostic Display
The ICU has a LED screen to
display all necessary values
for setup, operation and
maintenance.
Scope
The iFan system from Fläkt Woods
Intelligent Control Unit (ICU) offers a full range of box fans with
integral intelligent control unit
The iFan controller processes the signals from room/duct
a range of switches, sensors,
mounted sensors and/or switches, coordinating and
fittings and cabling to enable
interpreting these inputs, based upon a pre-determined
easy installation.
hierarchy enabling either automated or user controlled
ventilation systems.
The intelligent control unit, has a numeric display that
assists with the set up and enables monitoring of the
system operation. Output from the ICU displays,
running times, fan speeds, fault indication, service
intervals, damper or valve operation, temperature,
humidity, and CO2 levels.
The iFan ICU can also be controlled through a
building management system.
1
“Energy Management at affordable prices”
The Fläkt Woods’ iFan inline twinfan units are specifically Fans
designed to meet these requirements, offering 100% The fans are double inlet, double width type using a
standby with automatic changeover in the event of forward curve impeller fitted within a scroll and either
fan failure. directly connected or through a belt drive to their
The Fläkt Woods’ iFan inline single and twinbox fans are individual motors.
specifically designed to meet these requirements.
Motors
The motors are manufactured to BS5000. On direct driven
Sizes units anti-vibration mounts are fitted between the motor
mounting arms and impeller scroll. Overheat protection
iFan inline single fans (iFDDSF or IFDRSF). is a standard fitment to direct drive single
iFan 1,2,3,4,5,6,7,8, 8/4, 8/6 ILS. phase motors. Belt driven units have the mounts fitted
between a common fan base frame and the unit casing.
iFan inline twin fans (iFDDPF or IFDRPF).
iFan 1,2,3,4,5,6,7,8, 8/4, 8/6 ILT. Electrical Supply
220 - 240 V / 50 Hz / 1 φ
2
“An Integrated System”
3
“A Total Solution for Energy Management”
4
Dimensions
A
'C
'E'
'E'
11
E
75
AIRFLOW
'C'
'E'
'E'
11
E
75
ALTERNATIVE INTAKE
'D' LOCATION. FLEXIBLE
CONNECTIONS.
DISCHARGE 'E' 150
(IF ORDERED)
'A' (WIDTH) 210 SPIGOT.
MAX (IF ORDERED) 'B' (LENGTH)
VIEW ON
DISCHARGE END
5
Dimensions
Single Duct Mounting - Model DDSF (A) and (AL)
PLAN VIEW
38 'B' 38
FLEXIBLE
CONNECTIONS.
(IF ORDERED) ICU (IF ORDERED) ACCESS PANELS FITTED
NON RETURN FLAP
FITTED ON RIGHT TOP AND BOTTOM.
HAND SIDE.
AIRFLOW
'E'
'E'
'C'
'D'
'D'
'A'
MAX
60
21
15
EXTENDED
TERMINAL BOX
PLAN VIEW
FLEXIBLE 38 38
'B'
CONNECTIONS.
(IF ORDERED) ICU (IF ORDERED)
NON RETURN FLAP ACCESS PANELS FITTED
FITTED ON RIGHT
HAND SIDE. TOP AND BOTTOM.
AIRFLOW
'E'
'E'
'C'
'D'
'D'
'A'
150
EXTENDED
60
MAX
21
6
“Conserving Energy”
Electrical Data
220-240V/50Hz/1φ
Nominal Motor Nominal FLC
Product Speed Output SC
Code RPM Watts (AMPS) (AMPS)
DRPF/DDPF 1A (AL) or DRSF/DDSF 1A (AL) 1900 14.7 1.4 x 2 0.62
DRPF/DDPF 2A (AL) or DRSF/DDSF 2A (AL) 1250 35 2.0 x 2 0.94
DRPF/DDPF 3A (AL) or DRSF/DDSF 3A (AL) 1300 150 2.7 x 2 1.2
DRPF/DDPF 4A (AL) or DRSF/DDSF 4A (AL) 1300 150 4.0 x 2 1.8
DRPF/DDPF 5A (AL) or DRSF/DDSF 5A (AL) 1300 198 7.0 x 2 3.2
DRPF/DDPF 6A (AL) or DRSF/DDSF 6A (AL) 900 335 6.8 x 2 3.1
DRPF/DDPF 7A (AL) or DRSF/DDSF 7A (AL) 1300 550 13.7 x 2 6.2
DRPF/DDPF 8A (AL) or DRSF/DDSF 8A (AL) 900 736 19.5 x 2 8.7
DRPF/DDPF 8/4A (AL) or DRSF/DDSF 8/4A (AL) 1250 550 15.0 X 2 6.8
DRPF/DDPF 8/6A (AL) or DRSF/DDSF 8/6A (AL) 900 550 12.1 x 2 5.5
Sound Data
Sound Power Levels (dB) Break out
In Octave Bands Centre Frequency - Hz Sound
Product Level
Code 125 250 500 1000 2000 4000 8000 dBA @ 3m
Lined Unlined
DRPF/DDPF 1A (AL) or DRSF/DDSF 1A (AL) 65 62 59 55 53 50 47 34 34
DRPF/DDPF 2A (AL) or DRSF/DDSF 2A (AL) 65 58 51 53 52 50 47 31 31
DRPF/DDPF 3A (AL) or DRSF/DDSF 3A (AL) 66 59 50 54 53 51 48 31 31
DRPF/DDPF 4A (AL) or DRSF/DDSF 4A (AL) 70 63 54 58 57 55 52 35 35
DRPF/DDPF 5A (AL) or DRSF/DDSF 5A (AL) 72 65 56 60 59 57 54 37 37
DRPF/DDPF 6A (AL) or DRSF/DDSF 6A (AL) 75 73 70 71 71 65 63 37 37
DRPF/DDPF 7A (AL) or DRSF/DDSF 7A (AL) 78 75 75 79 80 76 70 51 53
DRPF/DDPF 8A (AL) or DRSF/DDSF 8A (AL) 77 75 77 75 74 71 66 51 52
DRPF/DDPF 8/4A (AL) or DRSF/DDSF 8/4A (AL) 79 78 74 76 74 71 65 50 52
DRPF/DDPF 8/6A (AL) or DRSF/DDSF 8/6A (AL) 73 74 74 75 73 69 64 49 50
Performance Data
600
500
400
Pressure Pa
8/4
300
200
8/6
8
100
2 3 4 7
5 6
1
0
0 0.5 1 1.5 2
3
Volume Flow m /s
5
We Bring Air to Life