Sei sulla pagina 1di 11

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR2488-06
April 2019

374F Excavator
Hydraulic System
EBF1-UP
NFJ1-UP
MFL1-UP
DNM1-UP
AT21-UP
AP41-UP
XWL1-UP

© 2019 Caterpillar CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, and the POWER EDGE trade dress as well as
All Rights Reserved corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION

Schematic Machine
Description
Location Location
Accumulator Gp D-2 1
Cylinder Gp - Boom D-7 38
Cylinder Gp - Bucket D-8 39
Cylinder Gp - Stick D-7 40
Filter Gp - Oil (Hydraulic Oil) A-6 2
Filter Gp - Oil (Hydraulic Return) A-8 3
Filter Gp - Oil (Tank) A-7 4
Manifold Gp - Solenoid C-2 5
Motor Gp - Fan (LH) C-7 6
Motor Gp - Fan (RH) B-7 7
Motor Gp - Piston (Swing Left) F-2 8
Motor Gp - Piston (Swing Right) F-3 9
Motor Gp - Piston (Travel) (LH) F-8 10
Motor Gp - Piston (Travel) (RH) F-7 11
Pump Gp - Fan B-4 12
Pump Gp - Main Hydraulic A-1 13
Pump Gp - Pilot Pressure B-3 14
Sensor Gp - Position (Drive Pump) A-3 15
Sensor Gp - Position (Idler Pump) A-1 16
Sensor Gp - Pressure (Boom Extend) C-4 17
Sensor Gp - Pressure (Boom Retract) C-6 18
Sensor Gp - Pressure (Bucket Extend) D-4 19
Sensor Gp - Pressure (Bucket Retract) D-6 20
Sensor Gp - Pressure (Drive Pump) D-4 21
Sensor Gp - Pressure (Idler Pump) E-4 22
Sensor Gp - Pressure (Stick Extend) F-4 23
Sensor Gp - Pressure (Stick Retract) F-6 24
Sensor Gp - Pressure (Swing) E-3 25
Sensor Gp - Pressure (Travel LH) C-8 26
Sensor Gp - Pressure (Travel RH) C-7 27
Swivel Gp E-7 28
Valve Gp - Check (Return Valve) E-6 29
Valve Gp - Check (Tank) A-7 30
Valve Gp - Main Control B-6 31
Valve Gp - Manifold (Pilot Pressure) D-3 32
Valve Gp - Pilot (Travel, Shuttle) D-8 33
Valve Gp - Reversing (Fan) B-7 34
Valve Gp - Swing Cushion E-2 35
Valve Gp - Travel Counterbalance (LH) E-8 36
Valve Gp - Travel Counterbalance (RH) E-7 37
TAP LOCATION

Tap Schematic
Description
Number Location
AA Drive Pump Pressure B-3
BB Idler Pump Pressure B-1
B1 Pump 1 NFC PRV Pressure C-2
B2 Pump 2 NFC PRV Pressure C-2
B3 Power Shift Pressure C-2
CC Case Drain Port Pressure A-4
PG Pilot Pump Delivery Pressure A-6
SOS Oil Sampling Port A-6
8 7 6 5 4 3 2 1

STICK SIDE
WARM - UP
SOL
Pi4
PM2-CV3
(10) MOTOR GP (11) MOTOR GP
Pi5 Dr4
PISTON (TRAVEL) (LH) PISTON (TRAVEL) (RH)
PMDr-CV3
228-3238 228-3238
STICK STICK
(HEAD) L6a R6 (ROD)
STICK EXTEND RETRACT STICK (8) MOTOR GP
EXTEND
PRV PC PRV CT
RETRACT PM2-SW
PRV CT PRV PC STICK PISTON (SWING LEFT)
F F
ANTI - DRIFT
VALVE 295-9414
DB PG1 PG2 DB
(23) SENSOR GP SWING

PRESSURE (STICK EXTEND) PG


BRAKE
SOL
PR
344-7392 PD
PP3 PP3
(24) SENSOR GP STICK
T1 PRESSURE (STICK RETRACT) (9) MOTOR GP
T1
344-7392 PISTON (SWING RIGHT)
T2 295-9416
B L BR T2 BR L B
A A PA PB PA PB

(22) SENSOR GP
M M
PRESSURE (STICK PUMP) TS
344-7392 A B A1 B1 (35) VALVE GP
Pi3b
AG SWING CUSHION
AG BG BG L5 (LEFT) 315-4394
BYPASS PS
TRAVEL (R) SWING R5 L5
pR4f LEFT
TRP2
PRV P-S

E R4 E
SHPi
STR TRAVEL (25) SENSOR GP (L)
A(LOWER) B(UPPER) A B B(LOWER) A(UPPER) L4 (R)
PRESSURE (SWING)
SWING A B
TRP1 344-7392
D C (29) VALVE GP pL4b
(36) VALVE GP (37) VALVE GP CHECK (RETURN VALVE)
(FWD) (BKWD)
TRAVEL COUNTERBALANCE (LH) (BKWD) (FWD) TRAVEL COUNTERBALANCE (RH) 369-8475
L3 R3 L4 R4 143-8067
K
143-8067
X
(28) SWIVEL GP H PUMP 2
295-9595 T1 A TR COMBINER
BYPASS
CUT PRV
Pi3a
B TL PM1-BYP
PM1-FAN PM2-CV1
2 SPEED T2
DRAIN J
TRAVEL FILTER
W L PM2-CV3
CONTROL
(38) BOOM CYLINDER PM1-BYP
(39) BUCKET CYLINDER (40) STICK CYLINDER
362-5998 380-7401 BHPi (21) SENSOR GP PM2-SW
362-8488
pL3b PRESSURE (BOOM PUMP) LINE PATTERNS
TLP1
PM2-TRL
344-7392 Pressure Line
L3 (32) VALVE GP
Dr3 PM2-CV2
PMDr-BYP MANIFOLD (PILOT PRESSURE) Pilot / Load Sensing Pressure
R3

PSA3
PSA4
PSA5

PSA2

PSA1
FLOW COMBINER STRAIGHT TRAVEL SWING
PRV 352-7080 Drain / Return Lines

Pi3

Pi2

Pi1
PRV RIGHT
PRV
PUMP 1 (1) ACCUMULATOR GP
HYD. Component Group
BYPASS P-BT 335-0546
D TLP2
pR3f CUT PRV LOCK D
TRAVEL (L) BYPASS PBT SOL CALLOUTS
R5 (RIGHT)
TS YY Taps (Pressure, Sampling, Sensor - by letter)
PMDr-CV2
BUCKET BUCKET
Dr2 Callout Number Component
(ROD) L2 (52) VALVE GP - CONTROL Name
BUCKET RETRACT EXTEND BUCKET Pi2 (Machine Location from
PM2-CV2 Component LocationsTable)
138-1234
L2 R2 R6 L6a L1 R1 RETRACT PRV PC
PRV PC
EXTEND Part Number
PRV CT PRV CT

(33) VALVE GP R2
PM2-TRL TRL-T
(HEAD) PAC HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
PILOT (TRAVEL, SHUTTLE)
TP PILOT PUMP OUTPUT

DR-OUT
DR5
369-8502

T-OUT

DR1
DR4

DR3

DR2
P-IN
BOOM PUMP OUTPUT
TT COOLING FAN PUMP AND CIRCUIT
(20) SENSOR GP (19) SENSOR GP PMDr-BYP
SUPPLY LINE
STICK CONTROL CIRCUIT
TRAVEL (L) TRAVEL (R) PRESSURE (BUCKET RETRACT) BUCKET PRESSURE (BUCKET EXTEND) LEFT TRAVEL MOTOR CIRCUIT
344-7392 344-7392 PM-T PMDr-T PMDr-CV3 SWING MOTOR CIRCUIT
DRAIN / RETURN LINE
SWING BRAKE CIRCUIT
PMDr-CV1 STICK PUMP OUTPUT
TRAVEL SPEED CONTROL CIRCUIT
PMDr-CV2 BUCKET CONTROL CIRCUIT
RIGHT TRAVEL MOTOR CIRCUIT
BOOM CONTROL CIRCUIT
POWER SHIFT CIRCUIT

BOOM BOOM MAIN RELIEF T


(FWD) (BKWD) (BKWD) (FWD) (ROD) L1 RETRACT BOOM
R1 (HEAD) 5SOL-T
BOOM EXTEND PRESS. CHANGE
RETRACT PRV PC EXTEND
PRV PC SOL PUMP 1 NFC
T2 T5 T1 T3 T6 T4 PRV CT BOOM TRAVEL PUMP 2 NFC PS PRESS
C C
PRV CT
PRV PRV EPRV
ANTI - DRIFT SPEED
TLP1 TLP2 TRP2 TRP1 VALVE CHANGE

B5 SOL P
(27) SENSOR GP BHPi
(26) SENSOR GP PRESSURE (TRAVEL RH)
(17) SENSOR GP SHPi A5
PRESSURE (TRAVEL LH) 344-7390 (5) MANIFOLD GP
(18) SENSOR GP BOOM PRESSURE (BOOM EXTEND)
344-7390 B3 SOLENOID
PRESSURE (BOOM RETRACT) 344-7392 2 SPEED B4 A4 A3 B2 A2 B1 A1
TRAVEL 447-1041
(6) MOTOR GP
344-7392
B3
FAN (LH)
CONTROL
B2 B1
364-0983

A A1 P

L2
BOOM SIDE
WARM - UP H3(A) CR(A) L5(A) L5(B) CR(B) H3(B)
LVE GP
(31) VA SOL

L3 MAIN CONTROL
DR B B1 381-1859 PMDr-CV1 PM2-CV1
T

Pi1 Dr1
A A2

B L3 B
P-BT P-S
X
L2
DR B B2
Dr Pi (34) VALVE GP
REVERSING (FAN)
AA BB
360-4604
(7) MOTOR GP
PM1-FAN
FAN (RH) MA MB
(14) PUMP GP A PA PB B
364-0983
(12) PUMP GP PILOT PRESSURE
DRAIN
FILTER
PG FAN 369-9658
P.P.O
448-9705
(13) PUMP GP
(4) FILTER GP
MAIN HYDRAULIC
OIL (TANK) MB1 B
369-9655
6E-5534
P.P.I
(30) VALVE GP (2) FILTER GP
CHECK (TANK) (16) SENSOR GP
OIL (HYDRAULIC OIL)
PM-T 352-7222 POSITION (STICK PUMP)
(30) VALVE GP 185-0336
CHECK (TANK) 369-9618
TRL-T G G
352-7222

5 SOL-T PMDr-T M1A T1 T2 T2 S M1B


A A
L1 L (15) SENSOR GP
S
POSITION (BOOM PUMP)
SOS CC 369-9618

THIS SCHEMATIC IS FOR THE 374F EXCAVATOR HYDRAULIC SYSTEM


(3) FILTER GP Do not operate or work on this product unless you have MEDIA NUMBER: UENR2488-06
read and understood the instruction and warnings in the
OIL (HYDRAULIC RETURN) relevant Operation and Maintenance Manuals and SCHEMATIC PART NUMBER: 349-1966, CHANGE: 08, VERSION: HE
relevant service literature. Failure to follow the instruc- Components are shown installed on a fully operable machine with the key and engine off.
188-4145 tions or heed the warnings could result in injury or
death. Proper care is your responsibility. Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

8 7 6 5 4 3 2 1
MACHINE COMPONENT LOCATIONS
VIEW ALL CALLOUTS
40

38

39

15 6 7

10

30
36

37 11
34

VIEW OF AREA “A”


(ROTATED FOR CLARITY)
CAB - TOP VIEW
VIEW ALL CALLOUTS

26 33 27
MAIN CONTROL VALVE - REAR VIEW
VIEW ALL CALLOUTS

20 23 31 22 24 25

18 32 29 21 1 19 17
MACHINE - FRONT VIEW

VIEW ALL CALLOUTS

9 28 8 35
MAIN PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

2 4

CC

14

12

SOS

PG

B1 B2 B3 5 13 16 BB AA

Potrebbero piacerti anche