 PSV Closed system Force #40425 ­ 01/24/11 11:37 PM

Nalibsyah    Go
Member    Dear All, Advanced
 
     
 
Registered: Who's Online
01/24/11  there is some issue that i need to clarify in this forum since i see that
Posts: 59   many expert in Piping Stress Engineering and COde Committe are 1 registered
Loc: Abu Dhabi visited this forum. (Mrragpicker), 8
 
The issue is about Force on PSV Closed system. Guests and 3 Spiders
 
As what i know that Force that show up when PSV in closed system online.
begin to firing is including in Impact Force so it is a dynamic event, but Key: Admin, Global Mod,
still we can use the quasi static method to analyze it by use the DLF Mod
factor.
 
As long as i know this event also not a static condition because the March
pressure will change rapidly when the PSV first firing. Su M Tu W Th F Sa
 
The problem of my concern is for this PSV Closed system i usually used
and consider not only the first impact/unbalanced forced in first elbow or 1 2
obstruction but also in the second elbow and other downstream this 3 4 5 6 7 8 9
PSV. 10 11 12 13 14 15 16
 
I also read in Peng book, that he mentioned that the event when PSV in
17 18 19 20 21 22 23
closed system firing still consider as Non static condition, so from here i
can take the conclusion there will be no Balanced force, it means Impact 24 25 26 27 28 29 30
force will occurs in each elbow or obstruction but in opposite direction. 31
We can measure each of this Force if we know the opening time of the 
PSV and multiply it with the length of each pipe section to get the Max. Forum Stats
Unbalanced force in each elbow or obstruction.
  11620 Members
But here in my new assignement i found a different method for client  
14 Forums
method, where Force downstream of PSV (other than force on first  
15757 Topics
elbow) are consider to be balanced each other. 
  70770 Posts  
I also found this method in one Engineering company that become a  
 
trade mark for Piping Engineering. Max Online: 126 @
 
So for all Expert and Collegues here, i ask for your advice, amybe 05/09/18 04:29 PM
opinion about this Issue.
 
Hope that it can give another value for all of us here.
Thanks.  
   
With Regards
Nalibsyah  
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: Nalibsyah] #40429 ­ 01/25/11 04:22 AM

stressguy81 
  As per API 520 Part 2, Cl. 4.4.2
 
Member  "  
 
    
Registered:
07/03/08  Pressure­relief devices that relieve under steady­state flow conditions
Posts: 71   into a closed system usually do not transfer large forces and bending
Loc: India moments to the inlet system, since changes in pressure and velocity
within the closed system components are small.
.....  
 
A complex time history analysis of the piping system may be required to
obtain the reaction forces and associated moments that are transferred  
to the inlet piping system."
   
 
As you said in general practice, the momentum component is imposed
as a reaction force at PSV.
http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 1/6
03/03/2019 PSV Closed system Force - Intergraph CADWorx & Analysis
generally divided as two cases,
 
Case1: When PSV pops up (Force imposed at PSV) and 
 
Case2: When there is established flow (When the forces cancel each
other)
   
 
You might find this topic interesting
   
http://65.57.255.42/ubbthreads/ubbthreads.php?
ubb=showflat&Number=11775#Post11775
 
http://65.57.255.42/ubbthreads/ubbthreads.php?
ubb=showflat&Number=24685#Post24685
   
 
I case of having a long run reaction forces can be imposed at the first
elbow at a different case, ex: F1 at PSV and F2 at first elbow in the
establised flow condition, conservatively.
   
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: stressguy81] #40430 ­ 01/25/11 06:35 AM

mariog   
Member    The only accident with PSVs in closed systems I know it is one in which
   
the PSV was wrong chosen and was chattering for years before piping
Registered:
09/29/07  was broken. It was a fatigue damage "assisted" by poor supports­ this
Posts: 665   was the conclusion of investigations. In my opinion it would have been
Loc: Romania avoided by common sense process/piping experience but also by field
operators feedback. 
   
Reversing the point of view, you can see in field PSV arrangements that
cannot be qualified by today calculations but have had a satisfactorily
service for long time.
   
I think any calculation for PSV in closed systems is good because offers
the opportunity to review the related piping and helps providing stiff
supports. For this point of view the calculation must be encouraged.
   
In the same time, I’m in doubt that 99% of these calculations would
simulate what it’s happening in field with PSV in a closed system.
That's why I don't want to say one approach is wrong and another one
is good. 
   
In addition, when the Client/Company regulations are hard (and usually
it is the case, because it seems to be o hot topic!) you have to comply
with.
   
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: mariog] #40431 ­ 01/25/11 07:33 AM

danb   
Member    I agree with mariog and stressguy81.
     
 
Registered:
04/22/05  I'd like to add the following.
 
Posts: 1311     
Loc: ... Check should be done for pop forces and if the velocities are close to 1
mach, apply forces at elbows equal with w x v (flow times velocity)
   
Regards,
_________________________
Dan  
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: danb] #40434 ­ 01/25/11 07:46 AM

MoverZ   
Member    A further warning about Mach speed ..... it cannot in most cases be
   
exceeded in a PSV body due to choking. Since velocity is not directly
Registered:
addressed in the equations given, the formulas in API RP 520 used to
http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 2/6
03/03/2019 PSV Closed system Force - Intergraph CADWorx & Analysis
11/22/06  calculate reaction forces can give incredible results. If you check the
 
Posts: 1195  associated velocity it may be well in excess of Mach speed and thus
Loc: Hants, UK
impossible. A reduction to a realistic mass flow rate should give better
force results.
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: MoverZ] #40435 ­ 01/25/11 08:17 AM

danb   
Member    Indeed, and this is in line with Norsok P­001 limiting criteria ro x v2 less
   
than 200 000.
Registered:  
04/22/05   
 
Posts: 1311  However a rough formula w x v = ro x v2 x A is quite reasonable. (e.g.
Loc: ... for a 8" line and a ro x v2= 200 000, force will be 7534 N) Not big, not
small, but will lead to a lot of guides and/or stops.
_________________________
Dan  
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: MoverZ] #40440 ­ 01/25/11 09:56 AM

mariog   
Member    Dear MoverZ
     
 
Registered:
09/29/07  You say
Posts: 665    
Quote:
Loc: Romania
Since velocity is not directly addressed in the equations given,
the formulas in API RP 520 used to calculate reaction forces
can give incredible results.
 
 
Well, I cannot blame the API formulas. Maybe the people applying API
formulas.
   
API formulas are based on "free jet" approach.
 
If a free jet is released in atmosphere or in a large volume, the piping
system will receive a reactive force. 
This is the force that API counts as:  
   
Reactive_Force= [mass flow­rate]*[jet_velocity]+ [p_jet]*[area_jet]
   
where
   
­ mass flow rate must be the actual value (it is greater than the
designed flow rate, because the actual PSV orifice is larger than
minimum required!)
 
­ jet_velocity is the critical speed when the jet gas flow has Mach=1
feature (is counted in Fluid Mechanics as jet_velocity= sqrt(2*R*k*T/
((k+1)*M)), where notations are as in API, R is the universal perfect­
gas constant , in SI is R=8314.5 J/kg mol/K.
 
­ p_jet is the gauge pressure in the released jet
 
­ area_jet is the internal area of piping at the point where the jet is
released
   
This is exactly the API formula, where the numerical coefficient is
sqrt(2*R), in SI units sqrt(2*8314.5)=129
 
Obviously, the formula is based on the "choked" condition i.e. Mach=1
and this is taken into consideration by counting jet_velocity=
sqrt(2*R*k*T/ ((k+1)*M)
   
A possible source of errors may be the term [p_jet]*[area_jet], because
it seems that "p" in chocked flow is somehow out of common
engineering perception and API does not give details on the subject.
   
I reattach a paper showing a simple way to evaluate pressure in
isentropic choked flow (Mach=1). You can see the same result in some
articles, but the fluid mechanics model is more complicated there.
   
http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 3/6
03/03/2019 PSV Closed system Force - Intergraph CADWorx & Analysis
 
My best regards.
 
 
Attachments 
 
Choked_flow_pressure.pdf (814 downloads)
   
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: mariog] #40441 ­ 01/25/11 10:10 AM

MoverZ   
Member    Thanks for the fluid mechanics lesson Mariog, I am well aware of theory.
   
My note was a warning since I have had occasion to check calculations
Registered:
11/22/06  where a small PSV apparently attracted a huge force, due exactly to the
 
Posts: 1195  error I outlined. People do make mistakes and far too many 'engineers'
Loc: Hants, UK apply equations blindly, because all too often they have found an
unchecked and non­validated Excel spreadsheet solution on some dodgy
company drive.
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: danb] #40449 ­ 01/25/11 03:56 PM

mariog   
Member    Dan,
     
 
Registered:
09/29/07  I think your example may be written as "if there is a free­jet exiting 8"
Posts: 665   piping area with (choked) parameters complying with rho*v^2=200000
Loc: Romania kg/(ms^2), the reaction force would be 7534 N". 
   
For a closed system I would say it is a "better than nothing" criteria. 
 
PS. I have a funny story with a PSV process issue in a big company that
after 2 months of Olga software calculation decided to have 24" size line
downstream of the 2"x4" piloted PSV. So 24" wasn't the subheader size,
it was the size connection to the subheader. The model was a visual
aggression and the calculation was "worse than nothing".
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: mariog] #40455 ­ 01/26/11 05:40 AM

danb   
Member    I think that I will not rephase as the purpose of this was more trivial.
     
 
Registered:
04/22/05  I was talking about flow induced forces. Decent problems require decent
 
Posts: 1311  solutions, sort of "better than nothing". For complex problems, there are
Loc: ... other solutions and I am not one of the specialists that can solve them.
   

_________________________
Dan  
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: danb] #40462 ­ 01/26/11 08:52 AM

mariog   
Member    Dan,
     
 
Registered:
09/29/07  You were talking about flow induced forces in closed systems and I was
Posts: 665   talking on the fact rho*v^2 transposed in "force criteria" would be a
Loc: Romania criteria for forces due to "free­jet" effect in open systems. I think also
that rho*v^2 is a steady­state criteria and does not address to the
"momentary, instantaneous forces that result when the valve first
opens".
   
The point is I have no evidence such criteria is a decent one in closed
system except the connection with subheader/header where a "free jet"
may exist. 
   
http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 4/6
03/03/2019 PSV Closed system Force - Intergraph CADWorx & Analysis
The only certitude I have is that every stress specialist and Company
has the certitude that his/her/their criteria is decent. I'm not in position
to say they are right or not, so I accept their approach, criteria, etc. 
   
It is interesting (for me) to see that the process people have the
certitude they don't know such decent criteria to evaluate roughly the
magnitude of forces in a closed system. I accept also their position.
   
Best regards.
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: PSV Closed system Force [Re: Nalibsyah] #43155 ­ 06/02/11 07:40 AM

Tengku_Syahdilan
  Stress guy and others, i think i need to clarify what asked. My
 
Member  concern is that when PSV first pop up there will be a travelling
   
wave downstream the PSV discharge or RV discharge. This load is
Registered: 12/26/09 
Posts: 56    not balanced each other. This force will have the same history
Loc: Indonesia shape throught out the system but the arriving time is different in
each point. This is why in API 520 as stress guy taken above
mention : 
 
A complex time history analysis of the piping system may be
required to
 
obtain the reaction forces and associated moments that are
transferred to the inlet piping system."
   
and in ASME B31.1 Non Mandatory App. II Para II.2.2.2 :
   
...."However when a safety valve discharge is connect to a
relatively long run of pipe and suddenly opened, there is a period
of transient flow until the steady state discharge condition is
reached.
   
and in Para II.2.3.2 :
   
......"Relief Valves discharging into an enclosed piping system
create a momentary unbalanced forces which act on the piping
system during the first few milliseconds following relief valve lift.
The pressure waves travelling through the piping system following
rapid opening of the safety valve will cause bending moments in
the safety valve discharge piping and the reminder of the piping
system. In such a case, the designer must compute the magnitude
of the loads and perform approriate evaluation of their effects."
   
LC Peng book page 401­403 so talk about this, where there will be
a net force impact on each leg (elbow or other obstruction)
downstream the RV or PSV discharge as a result of the traveling
wave or transient condition.
   
So what i mean is that we also have to considered the effect of
this transient load during pop not only at the first elbow ( i see in
some company standard they apply this two condition, during
steady state and pop up, but during pop up they only apply the
force directly upward and horisontal at the body of the Rv or
PSV.....i also have see some one post this kind of pictures in other
thread about PSV too).
   
Apply the load at n elbow/obstruction and n+1 elbow/obstruction,
but because it is quite complicated and we will not know the limit
of this travelling wave unless we perform simulation (maybe with
Boss fluid) or do the time history analysis for better and realistic
result, then it is common to assume to apply until the third
elbow/obstruction.
   
I have found a case where previous engineering company apply
the usual method (apply upward, and horizontal at valve body),
and the result the pump downstream of this RV system having a
trouble. so we fix it by apply and considered the transient effect
that not considered by previous company and now have been 3
years the pump still run smoothly.
   

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 5/6
03/03/2019 PSV Closed system Force - Intergraph CADWorx & Analysis
_________________________
Tengku_Syahdilan  
 
"From Failure we Learn"
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Search Results
 
Tweet

Like Be the first of your friends to like this.

 
Quick Reply:
HTML is
enabled
UBBCode  
is
enabled 
 Add  
Signature

 
Submit   Preview Reply   Switch to Full Reply Screen
 
Moderator:  Dave Diehl, Richard Ay  Hop to:     CAESAR II   Go
Privacy statement · Board Rules · Mark all read
GooG_v2_copy_copy_copy Contact Us · Home Page · Top

 
Generated in 0.043 seconds in which 0.024 seconds were spent on a total of 14 queries. Zlib compression disabled.
Powered by UBB.threads™ 7.5.7  

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=40440&Searchpage=10&Main=8903&Words=constant&Search=true#Post40440 6/6

Potrebbero piacerti anche