This document should be used as a guide only to instruct on the Xmaru PACS. For further
assistance on this user’s manual or Xmaru PACS, contact your dealer.
The User Manual that comes with the product may not contain the most updated
information on the product.
2
R-USM-203
Version: Rev.2
Date: 2017-06-09
3
Please note that this information is for proper use and safety of the XmaruView V1. The following
symbols may indicate a hazardous situation in which, if not heeded, may result in serious injury or
even death to the user or others, or damage to the equipment.
Intended use:
XmaruView V1(Xmaru Chiroview or Xmaru Podview) software carries out the image processing and
administration of medical X-ray data which includes adjustment of window leveling, rotation, zoom,
and measurements. XmaruView V1(Xmaru Chiroview or Xmaru Podview) is not approved for
mammography and is meant to be used by qualified medical personnel only. XmaruView V1(Xmaru
Chiroview or Xmaru Podview) is complying with DICOM standards to assure optimum
communications between network systems.
Xmaru PACS receives, stores, searches and views the diagnostic image data from imaging modalities
in DICOM compliant. Xmaru PACS is capable of communicating with electronic medical records
systems, hospital information systems, and radiology information system via DICOM standard.
XmaruView V1(Xmaru Chiroview or Xmaru Podview) and Xmaru PACS can be packaged together or
offered as a standalone imaging solution to be installed in a PC for trained medical professionals.
4
VATECH Dental Manufacturing Ltd.
Tel : +44 208 652 1990, Fax : +44 208 652 1909
www.rayence.com
Symbols Descriptions
Manufacturer
Date of manufacture
Serial number
5
Table of Contents
3. Studylist 13
4. Viewer 29
6
4.2 Thumbnail View ....................................................................................................................... 30
4.3.2 Navigation.............................................................................................................................. 31
5. CD Viewer 43
Appendix
1. Stitching 47
7
Customer Notice
1. Rayence Co., Ltd. does not notify the user of the product's features and performance can be
improved.
2. Some of the features of products in some countries, languages and currencies may not be
available.
3. Rayence Co., Ltd., without the consent of the product is illegal reproduction and distribution.
been recorded.
8
1. Introduction to Xmaru PACS
Xmaru PACS is a software program designed to provide image acquisition, processing and operational
management functions for Digital Radiography.
Xmaru PACS performs connects with Flat-Panel Detectors and Generator to acquire digital images.
The software also manages information on patients, tests and images through an internal database.
It also supports DICOM which allows excellent compatibility with other Radiography equipment and
network programs.
Xmaru PACS provides a streamlined process of multiple workflows. This optimizes any hospital
environment for digital radiography.
1.2 Copyrights
All software programs, files, data, manuals and other documents that are included in Xmaru PACS are
protected by the Copyrights Act and the Computer Program Protection Act of Republic of Korea.
More details on copyrights are included in product CD or in End User License Agreement that
appears when installing the product. Make sure to read it before using the product.
9
2. System Requirements of Xmaru PACS
The recommended system requirements for a proper execution of Xmaru PACS are as follows.
- CPU :Intel® Core™ i5 or higher
- Main memory(RAM) :4GB or higher
- Monitor Resolution :1920 x 1080
- Graphic Card
Intel Family :Intel GMA 950 or higher / Intel GMA X3500 or higher
Nvidia Family :Geforce FX5200 or higher
ATI Family :Radeon 9000 or higher
- Graphic Card memory :256MB or higher(No main memory sharing)
10
2.2 Start / Terminate Xmaru PACS
11
If you enter your ID & Password correctly and then click the button on the right
Xmaru PACS will be started.
Go to the top of the main screen and click the Exit button.
12
3. Studylist
①
②
③
Log off
13
Exit :End the program
② Search
Search by a variety of search conditions :Patient ID, Accession No., Body Part, Date, Physician,
Patient Name, Modality, Etc.
③ Main Tools
History Manager, DICOM send, DICOM Print, Save as, Export, Queue, Import
Open Study
④ Main List
-You can change the order of Header Column with Drag & Drop.
⑤ Thumbnail List
Display the list of thumbnails of studies selected from the Main list.
⑥ Reference List
Display the list of patient’s past study selected from the Main list.
14
3.2 Main Tools
15
3.2.2 Delete
① Select a patient you want to delete from the Study List and click “Delete”.
Check Box :When deleting, Except for the images yet to be sent.
16
3.2.3 History Manager: Administrator Only
17
3.2.4 DICOM Send
18
Storage Server
- Storage Server is registered in the list sent to select an item. (Multi selectable)
Send Mode
19
3.2.5 Print
DICOM Print
① ③
⑦ ⑧
②
⑨
< Figure 5 Printer Manager >
③ Print Information
20
MediaTypes :Select the Paper or Film Type.
④ Density
⑤ Overlay
⑥ Print Mode
21
Print registration is available to less than 20.
Paper Print
22
Advance Print
⑤
②
④ ⑥ ⑦
③ ⑧
⑨
⑩
⑪ ⑫
< Figure 7 Advance Print >
① Patient Information
② Study List
④ Main Screen
⑥ Preview
⑨ Option
- Select the Printer name and Film size, Orientation, Number of Copies
⑪ Setting
23
- Printer Setup configuration
<
Figure 8 Advance Print >
3.2.6 Save As
24
< Figure 9 Save As >
25
3.2.7 Export
※ Disk(Folder) : Save the study into a portable hard disk or user-defined path (Viewer included)
26
3.2.8 Queue
③ ④ ⑤ ⑥
⑦
< Figure 11 Queue >
① It shows the number of all studies and images that are currently being transmitted.
④ Abort :Abort transmission of the selected study. (The study whose transmission has
already been started may not be canceled even if it is deleted from the list.)
⑤ Abort All : Abort all operations that are currently registered. (The study whose
27
⑥ Retry :Retry transmission.
3.2.9 Import
28
4. Viewer
⑦
⑥
③ Close entire study, Call the Studylist, Hide thumbnail list icon, Hide the side tool bar
④ Thumbnail View
⑤ Title Bar
29
⑥ Main Screen
After selecting the image, Click the right button and then Pop-up list is displayed.
30
4.3 Side Tool Bar
4.3.1 Layout
Study Layout
Image Layout
4.3.2 Navigation
Previous Page
Next Page
Image View
Cine View
31
※ Extend Button :Extension tool window.
Previous Image
Next Image
32
③ Select the button you want to register and Click “Apply”
33
4.3.3 Image Controls
Select
- Default Cursor
- Select Functional button, Maker, Annotation, Cropping area etc.
Panning
Zoom
ROI Zoom
Magnify
- Hold the “Shift” key and move the mouse to adjust magnification.
- Hold the “Ctrl” key and move the mouse to adjust the size of the magnifying area.
Auto Fit
34
- Resize an image according to the size of the Main Screen.
CW 90º
CCW 90º
Horizontal Flip
Vertical Flip
Real Size
ROI Windowing
Invert
Compare View
Scout Image
Cross Reference
35
4.3.4 Tools
Length
Angle
ROI – Rectangle
ROI – Ellipse
Arrow
Marker –L
Marker –R
36
Marker –Text
Hold the control point and move the mouse to adjust the size of
the marker.
Delete Annotation
Note
- Writing Comment.
Annotation
Rectangle
37
- Insert the Rectangle Annotation.
Circle
Black Rectangle
Line
Acetabular Angle
Cobb’s Angle
Rectal Shutter
- The shutter can be rotate by drag the point at the middle of top side
38
Polygon Shutter
Center Point
Cross Angle
Line Segment
Free Draw
Dot
Stitching
Predefine Text
39
- The predefined text is entered.
- Go to System Menu > Setting > General > Display > Pre-Defined Text if you want to
40
4.3.5 Management
Save As
Send
Reset All
- Rotation, Flip, Window Width, Window Center and All annotations reset.
Adv Print
41
Paper Print
Report
Non-DICOM Import
Image Comments
42
5. CD Viewer
Automatically runs viewer when you insert the CD.
43
① ② ③ ④
44
① ② ③
- Image Layout
45
- Length, Angle, Rectangle / Circle ROI
② Main Screen
③ Thumbnail List
46
Appendix
1. Stitching
47
②
③
③ Tools
- Reset
48
④ BodyPart & View position Setting
- Select the BodyPart and View Position information of result image.
[BodyPart]
[View Position]
⑤ Stitching Function
- Insert Stitching Point
:Point in the image composite input on the screen.
- Delete Stitching Point
:Composite image input point to delete it.
- Select All image
:Select all the images are displayed.
- Swap Image
:Swap the images.
- Stitching
:If all images are entered in the stitch, stitching button is activated.
Composite images for based on stitching points.
- Close
:Close stitching function.
49
1.2 Image Stitching
50
< Figure 25 18Insert Stitching Point >
After clicking “Insert Stitching Point” button, enter the compositing point.
※ When you click the “Delete Stitching Point” button, delete the compositing point.
When you click the “Stitch” button, the preview window will pop up.
51
< Figure 26 19Image Stitching Preview >
52
< Figure 2720 Select Series >
Select Series
- Select a series after adding, click the “OK” button, you will be saved. “Cancel” to cancel
if you press the compositing.
53
< Figure 28 21Image Stitching Complete >
54
1