Sei sulla pagina 1di 4

Check List for Pile Cap Reinforcing Bar

Date: : .............…………………. Pier No. : ……....................……


Drawing No : ………………………….. Lift No. : ……………………………

Sky Bridge Pile Re-Bar Grade : BJTD 40


Cap PC16A
Main Bar Size & Number
CS
Top Rebar (T) Starter Bar

Ø T1
CT Face 2
Ø T2
5.1 m

Si
de ST
Re Link
ba
SS 1.7
ØS Fac 5.1 5 Fac
r m
e1 m e3
(S)

SB Ø Bn 1.75 m
Ø
B2
Ø B1 Face 4

Top View
Bottom Rebar (B) CB

The cover shall not less than the minimum cover shown on the drawing plus a tolerance 5 mm for side & top
The cover shall not less than the minimum cover shown on the drawing plus a tolerance 25 mm for bottom
CT, Cs, CB : Covering Minimum spacing rebar is size agregat coarse ( 25 mm ) and maximum is design spacing rebar + 1D
ST, SS, SB : Spacing Lap/splicing length shall not less than length shown on the drawing
Number & Diameter of rebar shall be same with design (Ø in milimeters)
Reinforcement Pile Cap Design Actual Criteria Result Location Design Actual Criteria Result
P OK / x Not P OK / x Not
Bottom Rebar Covering (mm)
Ø (mm) 40 same CB 75 75 - 100
B1 (01)
Qty (nos) 18 same CS 75 75-80
Ø (mm) 40 same CT 75 75-80
B1(05)
Qty (nos) 15 same
Ø (mm) 16 same
B1(12a)
Qty (nos) 12a same
Ø (mm) 40 same Spacing (mm)
B2(02)
Qty (nos) 23 same Botom Rebar
Ø (mm) 40 same SB1(01) 150 25 - 186
B2(06)
Qty (nos) 10 same SB1(07) 150 25 - 186
Ø (mm) 16 same SB2(02) 150 25 - 186
B2(12b)
Qty (nos) 20 same SB2(04) 150 25 - 186
Side Rebar
Ø (mm) 25 same
Horizontal

S1(09)
Qty (nos) 32 same

Statter bar Side Rebar


01sb Ø (mm) 36 same SS 150 25 - 175
Qty (nos) 20 same
02sb Ø (mm) 32 same Top Rebar
Qty (nos) 32 same ST1 150 25 - 179
Top Rebar ST2 150 25 - 179
T1 ( 03 ) Ø (mm) 32 same Lap /Splicing
Qty (nos) 33 same Location Design Actual Criteria Result
T2 (06) Ø (mm) 32 same Face 1a 550
Qty (nos) 33 same Face 1b 950
Links Face 2a 550
Link Pile Ø (mm) 36 same Face 2b 775
( 10') Qty (nos) 180 same Face 3a 550
Ø (mm) 16 same Face 3b 950
Links ( 11')
Qty (nos) 440 same Face 4a 550
Face 4b 775

Prepared By Site Engineer - NK Date Sign


Checked By QC - NK Date Sign
Checked By TEJ Date Sign
Check List for Column Reinforcing Bar
Date: : Pier No. : MS 5C……………………
Drawing No : ………………………………… Lift No. : ………………………………

Re-Bar Grade : BJTD 40


Column

Main Bar Size & Number

A1
CT Reinforcement Pier Design Actual Criteria Result
P OK / x Not
ST

Vertical Bar
Ø (mm) 40 same
A1
Qty (nos) 11 same

B1 SL B2 Ø (mm) 40 same
A2
Qty (nos) 11 same

Ø (mm) 40 same
B1
Qty (nos) 13 same

Ø (mm) 40 same
B2
Qty (nos) 13 same

A2 CL Horizontal Bar

Links Ø (mm) 13 same


1 Qty (nos) 24 same
Links Ø (mm) 13 same
2 Qty (nos) 20 same
CT & CL : Covering
ST & SL : Spacing

Covering & Spacing


+
Covering (mm) Spacing (mm)
Location Design Actual Criteria Result Design Actual Criteria Result
P OK / x Not P OK / x Not
Transverse (CT) A1
50 50-55 125 125 - 165

A2
50 50-55 125 125 - 165
Longitudinal (CL) B1
50 50-55 125 125 - 165
B2
50 50-55 125 125 - 165

Other Conditions (Surface Cleaning/Rust Removal)

Prepared By Site Engineer - NK Date Sign


Checked By QC - NK Date Sign
Acknowledged by TEJ Date Sign