Sei sulla pagina 1di 11

FEATURED PRODUCT

SHOWCASE April / May 2020

Inside this edition

CURRENT LIMITING DEVICE (CLD)

VIBRATION DAMPERS

PLP DISTRIBUTION HELICAL TIES


CURRENT LIMITING DEVICE (CLD)
CLD is classifed by their nominal discharge
current and high current impulse withstand
capabilities for a waveform of 8/20 μs. Cur-
rents from these standard waveforms will last
from 20 to 30 μs, in actual it’s even worse
when arrester is faced with multiple strokes.
This typical arrester is more adapted on
shielded line application
We tested our product at CESI Lab.
The external gap line arrester has a life expec-
tancy of 20 years and is one time investment
for your distribution line.

PLP-PA CLD installed in coordination with


Metal Oxide Arrester provides the best possi-
ble protection for transformers and line system
medium voltage covered conductor.

EFFECTIVE SOLUTION TO PROTECT MEDIUM VOLTAGE


INSTALLATIONS AGAINST LIGHTNING
EFFICIENT EFFECTIVE
Prevent insulator and conductor breakage No grounding to adjust and control
(depend on cross arm and pole material)
Protect sensitive components (MOA
arresters, transformers, etc.) No copper ground lead required
(depend on cross arm and pole material)
Avoid outages on the line
Self-protected product
Avoid short circuits (follow current)
No maintenance required
Fix and forget (20 years life expectancy)
One time investment for the line
Higher reliability of the line

INNOVATIVE TECHNOLOGY
Window relief SVU is simple and unique technolo-
gy able to prevent damage on SVU from lightning
discharge energy by release pressure in SVU due
to high energy impact. It requires NO additional
product (ground lead, ground rod) functions with
the conductivity of the pole and cross arm.

Manufacturing:
Sophisticated and stricted quality inspection for
varistor material is performed to ensure high quality
of CLD.

1 PREFORMED LINE PRODUCTS | INDONESIA


KARP INSULATION PIERCING CONNECTOR
vortx vibration dampe
tmCABLE IN MEDIUM VOLTAGE
FOR SPACER
KARP piercing connectors family have been developed to find
a need for tap connections in 15, 25 and 35kV Spacer Cables
without stripping and removing insulation from the conductors
and eliminating the need for weather-proofing and re-insulating,
can be installed in hot line and in any position. KARP connector
is composed of polymer components with resistance to ultravio-
let rays and busbar in copper (piercing type), supported on heli-
coidal springs. This innovative concept of supporting spring
busbar is the greater differential its design, because the springs
act in busbar keeping a permanent contact pressure on the con-
ductors, compensating for any possible diameter variations that
may happen in low quality conductors. KARP connector has its
technical characteristics be watertight and have tightening limit
control through the polymer fuse head. It has the option of the
stirrup for ground safety or for connection to the transformer,
which can be supplied separately or as a kit, connector + stirrup.

TYPE RANGING RANGING VOLTAGE INSULATION TORQUE NUMBER


OF
mm
2 2
mm kV COVER SCREWS
1 35 – 95 35 – 95 15/25 3 / 4 mm

KARP ACCESORIES
2 50 – 185 50 – 185 15/25 3 / 4 mm 1
3 120 – 300 120 – 300 15/25 3 / 4 mm
42-46 Nm
4 240 – 300 70 – 95/120 15/25 3 / 4 mm Developed by KRJ, the remote application
5 70 – 185 70 – 185 35 7,6 mm
2 device of the KARP connector has been
6 120 – 300 120 – 300 35 7,6 mm
designed to allow the application of the con-
nector + stirrup assembly, with hot stick
cutting down lineman
exposure to ener-
gized lines, offering
better safety, agility
and speed in the
execution of the
service. With the
Insulation
remote device the Piercieng +
connection of con- Spring Effect
nector+ stirrup can
be done from the
ground or bucket and the instalation of the
grounding point with KARP or connection
with transformer in the spacer cable becomes
faster and safer. Using this unique remote
application tool, the adapted for use with
standard hot stick, the service become to the
fastest safer hot-stick method available.

product showcase | April - May 2020 2


Spiral Vibration Damper
strand from wind-induced vibration.

PLP Spiral Vibration Damper reduces the Aeolian Vibration (the high frequency, low
amplitude vibration) caused by horizontal wind passing across the line.

Key Features;
• EASY to install.
• Made of solid thermal plastic.
• Non-corrosive.
• Effective in a broad range of frequencies.
• No concentrated mass or clamping pressure
that could damage guy wires.
• Provides impact-reactive damper protection
with helically-formed plastic rods.
• Reduces vibration on smaller diameter
cables.
• Available in standard or Hi mass type.

Conductor Range:
• 4.4mm - 19.3mm (Bare conductors, Shield Wires and OPGW)

3 PREFORMED LINE PRODUCTS | INDONESIA


vortx vibration damper tm
VORTX™ Vibration Dampers From the Recognised Leader in Conductor Protection

M uch of PLP’s business has developed from


over 60 years of studying and analysing the

It began in 1947 with PREFORMED™ Armor Rods,


originally designed to protect power cables from
abrasion and fatigue. PLP products are continually
tested and evaluated, both in the laboratory

systems or motion control.

The worldwide group of PLP companies have

motion control designs throughout our history.

.
Aeolian vibration is a high-frequency, low-
amplitude motion caused by smooth laminar

or cables are exposed to this wind type, a


phenomenon known as “vortex” shedding
occurs. Vortex, or “eddy” shedding as it is also known, creates
an alternating pressure imbalance above and below the PLP VORTX™ Damper respond to wind
conductor, inducing it to oscillate up and down at right angles induced line vibration that is characterized
discrete standing waves that can cause support hardware by high frequency, low amplitude motion
breakdown, conductor fatigue, abrasion, and eventually a.k.a. aeolian vibration. It exceeds the two
conductor failure.
response performance with a multi-response
Although potentially very destructive, these high frequency design that effectively reduces vibration over
(>5Hz), low amplitude (<1 cable diameter) standing waves
are almost invisible to the naked eye and require special a wider range of imposing frequencies.
instrumentation to detect their severity. In terms of the
frequencies observed, Aeolian vibration is directly related Key Features
to the laminar wind velocity and is inversely related to the
diameter of the cable. Thus, the higher the wind speed or the
smaller diameter of wire, the higher the vibration frequency. • Precision manufactured Galv steel messenger

Wind induced (aeolian) vibrations of conductors and overhead


• Damper clamp will hang from the conductor
shield wires (OHSW) on transmission and distribution lines can
produce damage that will negatively impact the reliability or during installation.
serviceability of these lines. Lines damaged by vibration may • Open galv ductile iron weights do not enclose the
have to be de-rated or even taken out of service until repairs
messenger, reducing the possibility of corrosion.
can be made. This could have an impact on an entire network.
Understanding aeolian vibration and how it can be managed • Breakaway bolt option.
• May be installed on either energised or
line or network.
unenergised lines.

product showcase | April - May 2020 4


PLP Polymer Strain Insulators
PLP Polymer Strain Insulators are designed for
tension or suspension applications in utility distribution
network for voltages 15, 25 and 35kV.

Key Features:
• Manufactured and tested at approved testing facility
as per IEC and Australian standards.
• Light weight and durable.
• Sheds manufactured from hydrophobic silicone rubber.

manufacturer.
• Available in higher creepage for coastal environment.
• Available in Kits (Insulator + Thimble + Eyebolt).

Available in kit form


Insulator + Thimble
+ Eyebolt

5 PREFORMED LINE PRODUCTS | INDONESIA


PREFORMED Deadend Grip TM
FOR BARE PHASE CONDUCTORS ALUMINIUM ALLOY

PLP’s PREFORMED™ Distribution-Grip Deadends are designed to be applied directly to bare


AAC, AAAC or ACSR conductors. Distribution-Grip Deadends can be applied to AAAC-S covered
conductors, but only after the sheath of the AAAC-S has been removed. Distribution-Grip Dead-
ends must never be applied over the sheath of an AAAC-S type covered conductor.

Distribution-Grip Deadends will hold 100% of the specified Conductor Breaking Load (CBL) when
directly applied to AAC, AAAC and small ACSR conductors.

Manufactured from either aluminium alloy or aluminium coated steel, Distribution-Grip Deadends
offer a unique design that eliminates bolts, nuts, washers and other component parts that may
become lost or damaged during installation or in service. Distribution-Grip Deadends should be
used only on the size and type of conductors for which they are designed.

All Distribution-Grip fittings have colour coded markings to indicate the starting point for application
and to assist in product identification.
Applied Length

Crossover Marks and Colour Code

Identification Tape
Gritted Legs

product showcase | April - May 2020 6


PLP Galvanised Clevis Thimbles
PLP Galvanised Clevis Thimbles are used in
conjunction with PREFORMED Dead-ends on
suspension-type or Dead-end insulators. The
thimble is intended to provide a smooth internal
contour to prevent stress concentration within
the loop of a PREFORMED Dead-end.

Key Features:
• Smooth internal contour to prevent stress concentration.
• Tested to IEC standards.
• Includes a humpback pin.
• Comes with a straining eye.
Part No: TC-17
• Galvanising to AS4680 standard.

Application / Suitability:
• Copper, Copper clad and Galvanised steel Preformed deadends (loop diameter up to 40mm)

PLP Aluminium Clevis Thimbles


PLP Aluminium Clevis Thimbles are used in
conjunction with PREFORMED Dead-ends on
suspension-type or Dead-end insulators. The
thimble is intended to provide a smooth internal
contour to prevent stress concentration within
the loop of a PREFORMED Dead-end.

Key Features;
• Smooth internal contour to prevent stress concentration.
• Tested to IEC standards.
• Includes a humpback pin.
• Made with high grade aluminium alloy. Part No: EPACT-70
• Comes with a straining eye.

Application / Suitability;
• Aluminium and Aluminium clad Preformed deadends (loop diameter up to 57mm)

7 PREFORMED LINE PRODUCTS | INDONESIA


PLP Distribution Helical Ties
For use in coastal and corrosive areas

PLP Aluminium Alloy Ties are designed to


secure conductors to a wide range of insulators.
Key Features:
• Designed for use in coastal and corrosive areas.
• Ties material have been performance matched to
aluminium conductors and are much more
corrosive resistant than standard
aluminized steel wires.
• Will not damage the conductor during installation.
• Easily applied by hand or with hot sticks.
• Resiliency built in to protect the conductor.
• Suitable for use with either ANSI compliant polymer
or porcelain insulators.
• Comes with or without pad.

Application / Suitability:
• Conductor Range: Up to 32mm
• Suitable for all aluminium based conductors
• Max Line Angle for vertical mounted insulator: up to 80°

Available As:
• Single Side Ties
• Single Top Ties
• Double Side Ties
• Double Top Ties
• Available in Kits (Armour Rod + Helical Tie)

product showcase | April - May 2020 8


PREFORMEDTM INSULATOR TIES - PLASTIC
SEMI-CONDUCTIVE PLASTIC TIES 35kV RATED
Semi-Conductive (Semi-Con) Plastic Ties are intended
for use with covered conductors and tie top ANSI C29.5
or C29.7 compliant insulators only.They are suitable for
use any covered conductor such as Tree Wire or
Spacer Cable.
Semi-Con Plastic Ties are made from a base of clear
PVC with a proprietary black co-extruded outer covering
selected for its superior electrical tracking resistance
properties. Use of this co-extruded material allows
applications on higher voltages and/or more stressful
electrical environments. This material was selected
because of its UV resistance, tensile, impact, and
flexural strength and self-extinguishing properties.

SEMI-CONDUCTIVE PLASTIC LINE TIE/TOP TIE


Applied Length
SEMI-CONDUCTIVE PLASTIC DOUBLE LINE TIE/TOP TIE

Relieved Ends

Relieved Ends Conductor Size Colour Code


Identification Tape (Identifies Conductor Size Range)

Insulator
Identification Mark
C Neck – Black,
F Neck – Yellow,
K Neck – Blue Conductor Size Colour Code
Identification Tape (Identifies Conductor Size Range)

15o Max
Insulator Identification Mark
C Neck – Black
F Neck – Yellow
K Neck – Blue

SEMI-CONDUCTIVE PLASTIC ANGLE SIDE TIE


Applied Length

15o Max

SEMI-CONDUCTIVE PLASTIC DOUBLE ANGLE SIDE TIE


Identification Tape Conductor Size Colour Code
(Identifies Conductor Size Range)
Relieved Ends Relieved Ends
Insulator Identification Mark
C Neck – Black
F Neck – Yellow
K Neck – Blue

Identification Tape
Conductor Size
Colour Code
SEMI-CONDUCTIVE PLASTIC TANGENT SIDE TIE (Identifies
Conductor
Insulator Identification Mark Size Range)
Applied Length C Neck – Black
30o Max F Neck – Yellow
K Neck – Blue

Relieved Ends
Identification Tape
Conductor Size Colour Code
(Identifies Conductor Size Range)
Insulator Identification Mark 30o Max
C Neck – Black
F Neck – Yellow

9 PREFORMED LINE PRODUCTS | INDONESIA


PT. Preformed Line Products Indonesia
Jl. Irian VII Blok MM-4-2, Kawasan Industri MM2100
Cikarang Barat, Bekasi 17520
Jawa Barat. Indonesia
Email: id.sales@preformed.com Phone: +62 21 8593 3899
Website: www.preformed.com
© 2020 Preformed Line Products Indonesia
04.20 www.preformed.com/id