Specif ications each constant potential circuit according to taining circuit breakers of the proper size. ln
the schedule. Each lack shall be of 50 ampere close proximity to the circuit breakers shall
The cross connect panel shall consist of a capacity. be a neutral bar terminal strip with sufficient
lactory finished welded steel wall mounted B. The 0.125" (3.2 mm) aluminum plug panel screw lug connections to connect all load
assembly containing all necessary plugs, jacks, shall support an insulating bushing and an neutral wires.
and circuit breakers to provide a flexible individual plug and cable for each load circuit. D. 20 amp and 50 amp plug
inter-connecting system between load circuits Plugs shall be U.L. approved Strand Century and cord sets with associated circuit breakers
and control outputs. The framework shall con- Saf-T-Patch@ with solid brass tips. Split tip of the same rating shall be provided.
sist of welded steel members completely cov- plugs will not be accepted. The plug shall have E. -
matching receptacle jacks, 50 am-
ered on all exposed surfaces with 0.125" a handle of high impact molded phenolic pere capacity shall be provided as follows:
(3.2 mm) aluminum panels. Exterior finish material with circuit identif ication number en-
shall be baked enamel. per 2.4 Kw Dimmer
graved at the base; contoured wider at the
A. The jack panels shall be of 0.125" (3.2 mm) base than near the tip. The tip shall be solid per 3.6 Kw Dimmer
aluminum with epoxy f inish suitably engraved brass with an insulated sleeve to provide 1007o per 4.0 Kw Dimmer
for identification. Jacks shall be Strand Cen- dead entry. An extra flexible cable shall be - per 6.0 Kw Dimmer
tury Saf-T-Patch@ U.L. approved, in which con- suspended from the bottom of the panel by - per 7.2 Kw Dimmer
tact surface is solid brass and pressure is means of a strain relief bushing and shall be -- per 12 Kw Dimmer
maintained by a steel spring. The spring shall of sufficient length so that any plug can be
not carry current or create any arc. No split connected to any jack. per 20 Amp Non Dim
receptacles will be accepted. The front of the These plugs and cables are stored on a hori- per 60 Amp Non Dim
jack shall be an insulating bead which pre- zontal load cord retaining shelf which is an Total
vents electrical contact except by a plug thrust integral part of the panel. Each cable shall
into the lack, the depth of the bead and insu- terminate in a properly identified circuit
-
lated portion of the plug tip being such that breaker to wh ich the contractor shall connect
an operator cannot receive a shock when in- the external lighting load circuit wires.
serting or removing plug f rom the Jack. There C. There shall be a circuit breaker panel con-
shall be jacks for each dimmer output and for