DIMMER BANKS CCR 300 series
STRAND CENTURY
?l
Fl
Rugged, heavy-duty rack designed to
7l
ol
(-) |
accommodate completely
ol
zl self-contained plug-in dimmers.
ol
crl
o Available in any size and configuration.
5I
url
Jl
ul
o Convection cooled - no fans required.
ol o Designed for maximum ease of inserting
zl
1l housing dimmers.
<l
OI
ccl
5l
r!l
rl
ul
o-
(o
II
nilil
- l\
ocr
<F
EZ
FL!
AO

oa
m -'l
zt
--r >
CZ
IO

-,*l'
lml
-
-.J
o)
E
m
l-
m
o
--l
t
o
r-
z
o
m
f-
m
STFIANtrl o
--l
n
o
z
:=*:T"_u_nY^ o
o
o
STRAND CENTURY INC. STRAND CENTURY INC. STRAND CENTURY LIMITED z-i
20 Bushes Lane 5432 West 102nd Street 6334 Viscount Road t
Elmwood Park, New Jersey 07407 Los Angeles, California 90045 Mississauga, Ontario, Canada r@
U.S.A. U.S.A. L4V 1 H3
Tel: (201) 791-7000 (212) 564-6910 Tel: (213) 776-4600 Tel: (416) 677-7130
Telex: 130322 Telex.653508 Telex:06968646
Strand Century Dimmer Banks CCR 300 series

1 CCR 300 Dimmer Modules


34', t +21" 2'1" * 31', t 2
3
Air lntake Area
Power and distribution section:
F--(864 mm)------J F(533mm)- f-(533mm)--l F(787mm) max.---1 Main f eeds, contactor relays, terminalstrips,
neutral buss, circuit breakers
I I

I I
Contractor's enlry area
I I
1
E E E 0 E
I
B E E
I m@ffi
I I

I I
FI-'.-.-.-_E
I I

I I
E E E E B E E E
I I

I I

I I

I I
B g E E B !l g I
I

I I (2057mm) max.
I I

I I

E I E E E
I

I
E E E
I
I I
I I
I I
I I

I I
E EI E E E E] 0 E I

I I

l--38" (965mm)-{-
I

25" (635mm)-{
I

I
(typical)

around the dimmer modules at a proper A. 4 KW dimmer spaces (stage)


Specif ications operating level provided the maxtmum am- B.- 6 KW dimmer spaces (stage)
The Di mer Equ i pment Ban k shal I consist of a bient room temperature does not exceed
m
free-standing, factory assembly o{ rack units 1 04'F (40'C). Forced air ventilation will not be
C.- 12 KW dimmer spaces (stage)
constructed with welded steel framework accepted. D. KW dimmer spaces (house)
members and .125" (3.2mm) standard sized Each individual dimmer tray shall include f ive E. ampere mercury relay non dims
aluminum alloy cover panels which shall be factory wired heavy duty f ree-f loating female with fully magnetic primary cir
secured to the framework assembly with jacks to ensure proper seating of the dimmer cuit breaker protection.
screws for ease of access. Steel trim pieces module male pins when the dimmer is inserted F. One transfer contactor lo bypass the house-
shall be provided for each corner of the com- into the lray. Two of these jacks shall be prop- light controllers and transfer the houselight
plete assembly and between each factory se- erly sized for line and load and the remaining dimmers to tull control voltage. The house-
cured modular unit. The finish shall be baked three for control. lights shall be instantly switched to full inten-
enameL The complete assembly shall be factory wired sity upon energization of any "Panic'switch
Each dimmer space shall consist oJ a pre- to properly identif ied load and control barrier- in any of the designated locations. The house-
formed steel tray which shall be factory type terminal strips located behind a remove- lights shall return to the control of the house-
welded to a complete tray and baffle sub- able front access panel at the top of each rack light conlrollers upon energization of any
assembly secured to the steel framework. The unit. The system shall be designed for 3 phase "Normal" switch.
tray and baffle sub-assemblies shall form a 4 wire,120/208V, 60 Hz. operation at- G. The main disconnect device as well as any
specially designed funnel" to facilitate the amperes/phase. miscellaneous additional relays and equip-
free flow of air around the dimmers. The {ront The Dimmer Equipment Bank shall not exceed ment shall be located in a separate power sec-
face panel of each sub-assembly shall be lou- x
81" H x 31" D" W, (2057mm Hx tion of the equipment bank. The entire system
vered f or air intake. The combination of the 787mmDx-mmW). shall be rendered operative or inoperative by
"funnels 'and mesh ventilation panels located an (electrically) (mechanically) operated 3
on top of each rack shall create a churning The Ban k shal I i nclude but not be li m ited to the
ollowing: phase main disconnect.
effect which shall maintain the temperature f

Copyright 1977 Strand Century lnc


Printed in Canada