Sei sulla pagina 1di 2

2.

2 Setting the Date and Time


Indicates a potentially hazardous situation 1. Know Your Monitor Positioning indicator 4. Wrap the wrist cuff firmly around your wrist. Do not apply 3. Using Your Monitor without a Smart Device
which, if not avoided, may result in minor or Your monitor has a built-in advanced positioning sensor Note over clothing.
Caution moderate injury to the user or patient, or cause 1.1 Contents that is used as an aid in determining if the monitor is at • Set your monitor to the correct date and time before taking a Check to make sure that there is no gap between your wrist 3.1 Taking a Measurement
damage to the equipment or other property. Monitor, 2 “AAA” alkaline batteries, storage case, instruction manual, the correct height. measurement for the first time. and the cuff. You can use your monitor without pairing to a smart device. To pair
• Stop using this monitor and consult with your physician if setup instructions • As soon as batteries are correctly installed, the year flashes on the your monitor with a smart device, refer to section 4.1.
N The “ ” symbol lights in blue when your monitor is at display of your monitor.
you experience skin irritation or discomfort. Note
Automatic Wrist Blood 1.2 Monitor the correct position relative to your heart during a • The date and time will automatically be set when the monitor is
• Consult with your physician before using this monitor on a • To stop the measurement, press the [START/STOP] button once
measurement. When your monitor is higher or lower paired with “OMRON connect” app. Refer to section 4.1.
Pressure Monitor wrist where intravascular access or therapy, or an arterio- 1 2 to deflate the wrist cuff.
position relative to your heart, the heart position locator
venous (A-V) shunt, is present because of temporary d
interference to blood flow which could result in injury.
bar will appear up above, or below the heart symbol to 1. Press the or button once to adjust the year.
Caution
guide correct wrist positioning.
RS7 Intelli IT (HEM-6232T-E) • Consult with your physician before using this monitor if you a Press and hold the button to quickly advance the years. • DO NOT use this monitor with other medical electrical (ME)
Instruction Manual have had a mastectomy. e Irregular heartbeat symbol equipment simultaneously. This may result in incorrect operation
• Consult with your physician before using this monitor if you Press and hold the button to quickly go backwards
b through the years. of the monitor and/or cause an inaccurate reading.
have severe blood flow problems or blood disorders as cuff Appears along with Normal Heartbeat Note
IM-HEM-6232T-E-EN-02-12/2018 f readings when an Pulse • Remain still and DO NOT talk while taking a measurement.
inflation can cause bruising. • Make sure the wrist cuff does not
2829393-8B
• DO NOT take measurements more often than necessary irregular rhythm is Blood pressure
2. Press the [START/STOP] button to confirm the year and cover the protruding part of the wrist
because bruising, due to blood flow interference, may occur. detected 2 or more the month will flash. Repeat the same steps to adjust bone on the outside of your wrist. 1. Press the [START/STOP] button.
Table of Contents • ONLY inflate the wrist cuff when it is applied on your wrist. g times during a the month, day, hour, and minute.
All symbols appear on the display before starting the
• Remove the wrist cuff if it does not start deflating during a measurement. Irregular Heartbeat measurement.
Introduction O An irregular heartbeat Short Long • If the wrist cuff comes
Important Safety Information measurement. Pulse out of the metal ring,
• DO NOT use this monitor for any purpose other than rhythm is defined as a 2. Check the positioning indicator.
1. Know Your Monitor slide it back through as
measuring blood pressure. rhythm that is 25% Blood pressure
Year Your monitor has a built-in advanced positioning sensor that is
2. Preparation shown in the figure to
• During measurement, make sure that no mobile device or any less or 25% more used as an aid in determining if the monitor is at the correct
3. Using Your Monitor without a Smart Device c h the right.
other electrical device that emits electromagnetic fields is than the average rhythm detected while your monitor is Month height. It has been designed to work with most people so that
4. Using Your Monitor with a Smart Device measuring blood pressure. If it continues to appear, we
within 30 cm of this monitor. This may result in incorrect when your wrist is at the correct position relative to your heart,
5. Using Memory Function recommend you to consult with and follow the directions Day
operation of the monitor and/or cause an inaccurate reading. a. Wrist cuff
6. Other Settings of your physician. the “ ” symbol will light in blue. When your wrist is higher or
• DO NOT disassemble or attempt to repair this monitor or (Wrist circumference 13.5 cm to 21.5 cm)
7. Error Messages and Troubleshooting Hour 2.5 Sitting Correctly lower position relative to your heart, a locator bar will appear
other components. This may cause an inaccurate reading. b. Display
8. Maintenance • DO NOT use in a location where there is moisture or a risk of Movement error symbol To take a measurement, you need according to the wrist position. Due to difference in individual
9. Specifications c. [User ID selection] switch
water splashing this monitor. This may damage this monitor. Appears along with readings when your body is moving Minute to be relaxed and comfortably size and physique, this feature may not be helpful in all cases
10. Limited Warranty d. [Memory] button
• DO NOT use this monitor in a moving vehicle such as in a car. P during a measurement. If it appears, remove the wrist seated in a room with a and you may wish to disable this feature. If you feel the position
11. Guidance and Manufacturer’s Declaration e. [Morning average] button
cuff, and wait for 2 to 3 minutes. Then, remain still and
3. Press the [START/STOP] button to store the setting. comfortable temperature. Place
• DO NOT drop or subject this monitor to strong shocks or f. [START/STOP] button of the wrist according to positioning indicator's guidance does
vibrations. take another measurement. It automatically turns off after 3 seconds. your elbow on the table to support
g. [Connection] button NOT match your heart level, disable this feature and follow
Introduction • DO NOT use this monitor in places with high or low humidity your arm. your judgement. To disable it, refer to section 6.1.
h. Battery compartment Note
or high or low temperatures. Refer to chapter 9. Cuff wrap guide symbol (OK)
Thank you for purchasing the RS7 Intelli IT Automatic Wrist Blood • If you need to reset the date and time, replace batteries or press
• Ensure this monitor is not impairing blood circulation by 1.3 Display and Symbols Appears if the wrist cuff is wrapped around the wrist • Sit in a chair with your legs
Pressure Monitor. This blood pressure monitor is to be worn on your observing the wrist while measurement is occurring. correctly while taking a measurement. It also appears and hold the button until the year flashes, and set the date uncrossed and your feet flat on
wrist. • DO NOT use this monitor in high-use environments such as A K when viewing past readings. and time as above steps. the floor.
This blood pressure monitor uses the oscillometric method of blood medical clinics or physician offices. Q • Sit with your back and arm
pressure measurement. When the cuff inflates, this monitor senses • DO NOT use this monitor with other medical electrical (ME) B L Cuff wrap guide symbol (loose) 2.3 Blood Pressure Measurement Tips being supported.
the pressure pulsations of the artery underneath the cuff. The pulses equipment simultaneously. This may result in incorrect Appears if the wrist cuff is not wrapped around the wrist To help ensure an accurate reading, follow these directions: • Your monitor must be
are called oscillometric pulses. The electronic pressure sensor operation of the monitor and/or cause an inaccurate reading. correctly while taking a measurement. It also appears • Stress raises blood pressure. Avoid taking measurements during approximately the same level
displays a digital reading of blood pressure. • Avoid bathing, drinking alcohol or caffeine, smoking, when viewing past readings. stressful times. as your heart. If the monitor is
C
Safety Instructions exercising and eating for at least 30 minutes before taking a • Measurements should be taken in a quiet place. too high above your heart, your blood pressure will be artificially
M • It is important to take measurements at same times each day.
This instruction manual provides you with important information measurement. Battery symbol (low) low. If the monitor is too low below your heart, your blood pressure
• Rest for at least 5 minutes before taking a measurement. Flashes when batteries are low. Taking measurements in the morning and in the evening is will be artificially high.
about the RS7 Intelli IT Automatic Wrist Blood Pressure Monitor. To
ensure the safe and proper use of this monitor, READ and • Remove tight-fitting, thick clothing and any accessories from D R recommended. • Relax your wrist and hand. Do not bend your wrist back, clench
UNDERSTAND all of the safety and operating instructions. If you do your wrist while taking a measurement. Battery symbol (depleted) • Remember to have a record of your blood pressure and pulse your fist, or bend your wrist forward.
• Remain still and DO NOT talk while taking a measurement. Appears when batteries are depleted. readings for your physician. A single measurement does not
not understand these instructions or have any questions, contact
• ONLY use this monitor on persons whose wrist provide an accurate indication of your true blood pressure.
your OMRON retail outlet or distributor before attempting to use this N
circumference is within the specified range of the cuff. Bluetooth ON symbol Please use the Blood Pressure Diary to keep records of several Monitor height Positioning indicator
monitor. For specific information about your own blood pressure, E
• Ensure that this monitor has acclimated to room temperature O Appears when Bluetooth is enabled. readings over a certain period of time. To download PDF files of
consult with your physician. S
before taking a measurement. Taking a measurement after an the diary, visit www.omron-healthcare.com. Any locator bar (-) above
Intended Use extreme temperature change could lead to an inaccurate F P Bluetooth OFF symbol Wrist is too high
This device is a digital monitor intended for use in measuring blood Appears when Bluetooth is disabled. Caution the “ ” symbol appears.
reading. OMRON recommends waiting for approximately 2 2.6 Selecting a User ID
pressure and pulse rate in adult patient population with wrist G Q • Avoid bathing, drinking alcohol or caffeine, smoking, exercising
hours for the monitor to warm up or cool down when the Your monitor is designed to take measurements and store the
circumference ranging from 13.5 cm to 21.5 cm. This monitor monitor is used in an environment within the temperature 2013 ESH/ESC* Guidelines for the management of and eating for at least 30 minutes before taking a measurement. Proper position The “ ” symbol lights in blue.
detects the appearance of irregular heartbeats during measurement readings in the memory for 2 people using the [user ID selection]
specified as operating conditions after it is stored either at H R arterial hypertension • Rest for at least 5 minutes before taking a measurement.
and gives a warning signal with readings. It is mainly designed for switch.
the maximum or at the minimum storage temperature. For Definitions of hypertension by office and home blood pressure levels Any locator bar (-) below
general household use. additional information of operating and storage/transport I 1. Select your user ID (1 or 2). Wrist is too low
Receiving and Inspection temperature, refer to chapter 9. Office Home 2.4 Applying the Wrist Cuff the “ ” symbol appears.
J S
Remove this monitor from the packaging and inspect for damage. If • DO NOT crease the wrist cuff excessively. Note
this monitor is damaged, DO NOT USE and consult with your • Read and follow the “Correct Disposal of This Product” in Systolic Blood • Following steps are for applying the wrist cuff to your left wrist.
≥ 140 mmHg ≥ 135 mmHg
OMRON retail outlet or distributor. chapter 11 when disposing of the device and any used Pressure Note
A Date and time display When you take a measurement on your right wrist, apply the wrist
accessories or optional parts. • After 5 seconds from pressing the [START/STOP] button,
cuff using the same steps as on your left wrist.
Diastolic Blood even if your monitor is not positioned properly, your monitor
• DO NOT use this monitor after the durable period has ended. Average value symbol ≥ 90 mmHg ≥ 85 mmHg • The blood pressure can differ between the right wrist and the left
Important Safety Information Refer to chapter 9.
Pressure will start the measurement and the wrist cuff will start to
B Appears when viewing the average readings of the wrist, and the measured blood pressure values can be different.
Please read the Important Safety Information in this instruction inflate.
Data Transmission latest 2 or 3 readings taken within 10 minutes span. OMRON recommends to always use the same wrist for
manual before using this monitor. These ranges are from statistical values for blood pressure. measurement. If the values between both wrists differ
• DO NOT replace batteries while your reading is being 3. Remain still and do not move or talk until the entire
Please follow this instruction manual thoroughly for your safety. transferred to your smart device. This may result in the Memory symbol * European Society of Hypertension (ESH) and European Society substantially, please check with your physician as to which wrist to
C measurement process is completed.
Please keep for future reference. For specific information about your incorrect operation of this monitor and failure to transfer your Appears when viewing readings stored in the memory. of Cardiology (ESC). use for your measurements.
As the cuff inflates, your monitor automatically determines your
own blood pressure, CONSULT WITH YOUR PHYSICIAN. blood pressure data.
D Systolic blood pressure reading Caution ideal inflation level. This monitor detects your blood pressure
Battery Handling and Usage Warning and pulse rate during inflation.
Indicates a potentially hazardous situation • Remove tight-fitting, thick clothing and any accessories from your
• DO NOT insert batteries with their polarities incorrectly
Warning which, if not avoided, could result in death or E Diastolic blood pressure reading • NEVER diagnose or treat yourself based on your readings. wrist while taking a measurement. The “ ” symbol flashes at every heartbeat.
serious injury. aligned.
• ONLY use 2 “AAA” alkaline batteries with this monitor. DO ALWAYS consult with your physician.
Pulse display / Memory number Note
• DO NOT use this monitor on infants, toddlers, children or NOT use other types of batteries. DO NOT use new and used
persons who cannot express themselves. Pulse rate appears after the measurement. 1. Apply the wrist cuff to your left • The “ ” symbol appears if the wrist cuff is wrapped
batteries together. DO NOT use different brands of batteries wrist. around the wrist correctly.
• DO NOT adjust medication based on readings from this blood F When pressing the
together. button, the memory number appears 2. Preparation Roll up sleeve. Make sure your • When the “ ” symbol is displayed, the wrist cuff is not
pressure monitor. Take medication as prescribed by your • Remove batteries if this monitor will not be used for a long for approximately one second before the pulse rate appears on
physician. ONLY a physician is qualified to diagnose and treat sleeve is not rolled up too tightly on applied correctly. Press the [START/STOP] button to turn
period of time. the display. 2.1 Installing Batteries your arm. This may constrict the flow
high blood pressure. your monitor off, then apply the cuff correctly.
• If battery fluid should get in your eyes, immediately rinse with
• DO NOT use this monitor on an injured wrist or a wrist under Deflation symbol 1. Push down the hook of the of blood in your arm.
plenty of clean water. Consult with your physician G
medical treatment. Appears during cuff deflation. battery cover and pull After your monitor has detected your blood pressure and pulse
immediately.
• DO NOT apply the wrist cuff on your wrist while on an • If battery fluid should get on your skin, wash your skin downward. 2. Put your wrist through the cuff loop. rate, the cuff automatically deflates. Your blood pressure and
intravenous drip or blood transfusion. Heartbeat symbol Your palm and monitor display should both pulse rate are displayed.
immediately with plenty of clean, lukewarm water. If irritation, H
• DO NOT use this monitor in areas containing high frequency Flashes while taking a measurement. face upward. If either the systolic or the diastolic reading is high (refer to
injury or pain persists, consult with your physician.
(HF) surgical equipment, magnetic resonance imaging (MRI) • DO NOT use batteries after their expiration date. section 1.3), the “ ” symbol appears.
equipment, computerized tomography (CT) scanners. This • Periodically check batteries to ensure they are in good Sync symbol
may result in incorrect operation of the monitor and/or cause working condition. Flashes/appears when your data needs to be 2. Insert 2 “AAA” alkaline batteries
an inaccurate reading. • ONLY use batteries specified for this monitor. Use of transferred because the stored memory is either as indicated in the battery
• DO NOT use this monitor in oxygen rich environments or near unsupported batteries may damage and/or may be hazardous almost, or completely full. Once you pair your monitor compartment.
flammable gas. I Wrist cuff
to this monitor. with a smart device, transfer your readings immediately
• Consult with your physician before using this monitor if you before the monitor deletes the oldest readings. Up to
have common arrhythmias such as atrial or ventricular 100 readings can be stored in the internal memory per
3. Position the wrist cuff leaving a
premature beats or atrial fibrillation; arterial sclerosis; poor clearance of 1 to 2 cm between
user. START INFLATING COMPLETED
perfusion; diabetes; pregnancy; pre-eclampsia or renal 3. Close the battery cover. the cuff and the bottom of your
2 palm.
disease. NOTE that any of these conditions in addition to OK symbol
patient motion, trembling, or shivering may affect the 4. Press the [START/STOP] button to turn your monitor off.
J Flashes when your monitor is connected to the smart
measurement reading. device or readings are transferred successfully. 1 to 2 cm Note
• NEVER diagnose or treat yourself based on your readings. • Your monitor will automatically turn off after 2 minutes.
ALWAYS consult with your physician. Morning average symbol 1 • Wait 2-3 minutes between measurements. The wait time
• This product contains small parts that may cause a choking Appears when viewing the weekly average readings allows the arteries to decompress and return to their pre-
hazard if swallowed by infants, toddlers or children. K taken in the morning. measurement form. You may need to increase the wait time
Note
Data Transmission Weekly averages for the measurement taken in the • When the “ ” symbol flashes on the display, it is recommended depending on your individual physiological characteristics.
• This product emits radio frequencies (RF) in the 2.4 GHz morning within 4 weeks appear on the display. you replace batteries.
band. DO NOT use this product in locations where RF is • To replace batteries, turn your monitor off and remove all batteries.
restricted, such as on an aircraft or in hospitals. Turn off the User ID symbol Then replace with 2 new alkaline batteries at the same time.
Bluetooth feature in this monitor and remove batteries when L The user ID number appears when selecting the user • As soon as batteries are correctly installed, the year flashes on the
in RF restricted areas. with [user ID selection] switch. date and time display to set the date and time.
Battery Handling and Usage • Replacing batteries will not delete previous readings.
Hypertension symbol • The supplied batteries may have a shorter life than new batteries.
• Keep batteries out of the reach of infants, toddlers or
children. Appears if your systolic blood pressure is 135 mmHg or • Disposal of used batteries should be carried out in accordance
above and/or the diastolic blood pressure is 85 mmHg with local regulations.
M or above.

Morning hypertension symbol


Appears when the morning weekly average is 135/85
mmHg or above.
4. Using Your Monitor with a Smart Device 5. Using Memory Function 6. Other Settings Display/
Possible Cause Solution 9. Specifications 11. Guidance and Manufacturer’s Declaration
Problem
Your monitor automatically stores up to 100 readings per user.
4.1 Pairing Your Monitor with a Smart Device 6.1 Disabling/Enabling Positioning Indicator Product category Electronic Sphygmomanometers
The date and time on your monitor will automatically be set when The positioning indicator is enabled as default. Flashes when pairing to
5.1 Viewing the Readings Stored in Memory The [ ] button is the smart device. Visit Product description Automatic Wrist Blood Pressure Monitor
you pair your monitor with your smart device. • This device fulfils the provisions of EC directive 93/42/EEC
Review the list of compatible smart devices at 1. Select your user ID. 1. Select your user ID. pressed and held to pair the “Help” section in the Model (Code) RS7 Intelli IT (HEM-6232T-E) (Medical Device Directive).
www.omronconnect.com/devices/ flashes with a smart device. “OMRON connect” app Display LCD digital display • This blood pressure monitor is designed according to the
2. When your monitor is off, press and hold the button for pairing. European Standard EN1060, Non-invasive sphygmomanometers
1. Enable Bluetooth on your smart device. 2. Press the button. Cuff pressure range 0 to 299 mmHg
for more than 10 seconds. Part 1: General Requirements and Part 3: Supplementary
Alternating Flashes when Blood pressure SYS: 60 to 260 mmHg requirements for electromechanical blood pressure measuring
The [ ] button is
2. Download and install the free “OMRON connect” app date/time transferring your measurement range DIA: 40 to 215 mmHg systems.
pressed to transfer your
onto your smart device. display
flashes readings to the Pulse measurement • Hereby, OMRON HEALTHCARE Co., Ltd., declares that the radio
readings. 40 to 180 beats / min.
“OMRON connect” app. range equipment type HEM-6232T-E is in compliance with Directive
Pressure: ±3 mmHg 2014/53/EU.
More than 80 readings Accuracy
Pulse: ±5% of display reading • The full text of the EU declaration of conformity is available at the
are not transferred.
Pair or transfer your following internet address: www.omron-healthcare.com
If you already have the “OMRON connect” app, open the app Inflation Automatic by electric pump
The Memory number appears for one second before the pulse
Note
flashes This monitor is ready for readings to the • This OMRON product is produced under the strict quality system
and add your new monitor. • Your monitor will automatically turn off after 3 seconds from “OMRON connect” app Deflation Automatic rapid deflation of OMRON HEALTHCARE Co., Ltd., Japan. The Core component
rate is displayed. The most recent reading set is numbered “1”. pairing or transferring
the completion. your readings. so you can keep them Measurement method Oscillometric method for OMRON blood pressure monitors, which is the Pressure
3. Open the app on your smart device and follow the • To enable the positioning indicator, follow the same steps as in memory in the app, Sensor, is produced in Japan.
Transmission method Bluetooth® low energy technology
instructions. Note above. and this error symbol
100 readings are not Frequency range: 2.4 GHz (2400 - Symbols description
• If the positioning indicator is enabled, the positioning disappears.
4. Confirm that your monitor is indicator is displayed with the readings. 6.2 Deleting All Readings Stored in Memory transferred. Wireless communication
2483.5 MHz)
connected successfully. appears Modulation: GFSK Applied part - Type BF
• If the reading is high (refer to section 1.3),
1. Select your user ID. Effective radiated power: < 20 dBm Degree of protection against electric
the “ ” symbol appears. shock (leakage current)
When your monitor is connected Operation mode Continuous operation
• If there are no readings stored in the
successfully to your smart device, the 2. Press the button, then the “ ” symbol appears. IP classification IP 22
memory, the screen to the right is Ingress protection degree provided by
“OK” symbol flashes. displayed.
3. While holding the
Rating DC3 V 3.0 W IP XX IEC 60529
• If the memory is full, the monitor will Power source 2 “AAA” alkaline batteries 1.5V
delete the oldest readings. button down, press heart symbol Enable the positioning Approximately 300 measurements (using CE Marking
and hold the [START/ The positioning indicator Battery life
indicator. Refer to new alkaline batteries)
STOP] button for more The heart is disabled.
section 6.1. Durable period (Service
Note
3. Press the button repeatedly to scroll through the than 2 seconds. symbol in the 5 years
previous readings stored in the memory. positioning life) Serial number
• If the “Err” symbol appears, follow the Note indicator does +10°C to +40°C / 15 to 90% RH (non-
instructions in the “OMRON connect” • All readings will be deleted. Operating conditions
5.2 Viewing the Average Reading not light and a condensing) / 800 to 1060 hPa
app. You cannot partially delete
• Your monitor automatically turns off Your monitor can calculate an average reading based on the latest 2 locator bar does Storage / Transport -20°C to +60°C / 10 to 90% RH (non- Temperature limitation
the readings stored in the not appear.
after 10 seconds without any or 3 readings taken within 10 minutes span. memory. conditions condensing)
operations. Replacing all batteries Approximately 91 g not including
• Any readings currently saved in the memory of your monitor 1. Select your user ID. Weight
Humidity limitation
6.3 Restoring Your Monitor to the Default Settings with 2 new alkaline batteries
are automatically transferred to the app after successful To delete all the information stored in your monitor, follow the
2. When your monitor is off, press and hold the Batteries are low. batteries is Approximately 91 mm (w) × 63 mm (h) ×
completion of the pairing process. instructions below. Make sure that your monitor is turned off. flashes recommended. Refer to Dimensions 13 mm* (l)
• Please be aware that OMRON will not be responsible for the button for more than 2 seconds. section 2.1. (not including the wrist cuff) Atmospheric pressure limitation
loss of data and/or information in the app.
• “OMRON connect” is the only app that we recommend to use Note
1. While holding the Measurable wrist
button down, press the 13.5 to 21.5 cm
with your monitor to transfer data correctly. • If there are only 2 readings in the circumference
[START/STOP] button To indicate generally elevated, potentially
memory for that period, the average appears or the Memory Stores up to 100 readings per user hazardous, levels of non-ionizing
will be based on these 2 readings. within 2 seconds. Hold
4.2 Taking a Measurement both buttons for more than monitor is
Immediately replace all Monitor, storage case, 2 “AAA” alkaline radiation, or to indicate equipment or
Refer to section 3.1 to start a measurement. The readings will be • If the average reading is high (refer turned off Batteries are depleted.
5 seconds. batteries with 2 new Contents batteries, instruction manual, setup systems e.g. in the medical electrical
transferred to your smart device. to section 1.3), the “ ” symbol unexpectedly
alkaline batteries. Refer instructions area that include RF transmitters or that
appears. Note during a
Note to section 2.1. Protection against intentionally apply RF electromagnetic
• Reverting to its default measurement Internally powered ME equipment energy for diagnosis or treatment.
• If your profile has been registered, once the [START/STOP] button electric shock
5.3 Viewing Morning Weekly Averages setting of your monitor does
is pressed, your birthday is displayed and the user ID symbol not delete the information in Batteries are completely Applied part Type BF (wrist cuff)
Your monitor calculates and displays weekly averages for the Need for the user to consult this
flashes twice. the app. No power. depleted.
measurements taken in the morning for 4 weeks per user. Maximum temperature instruction manual.
• Your monitor will automatically turn off after 3 seconds. Nothing Lower than +48°C
4.3 Disabling/Enabling Bluetooth of the applied part
1. Select your user ID. • You will need to re-pair your monitor when using the monitor appears on the Check the battery
Indicates the correct positioning for the
Disable Bluetooth in your monitor in the following areas where use of display of the Battery polarities are not installation for proper
again. Without re-pairing, your readings will not be * thinnest part monitor on the wrist
wireless equipment is prohibited. transferred to your app. monitor. properly aligned. placement. Refer to
• On aircraft • In hospitals • While abroad 2. Press the button once.
Note
Measurable wrist circumference
section 2.1.
Bluetooth is enabled as default. The morning weekly average for the • These specifications are subject to change without notice.
current week “THIS WEEK” appears on 7. Error Messages and Troubleshooting Blood pressure varies constantly. Many factors • In the clinical validation study, K5 was used on 85 subjects for Indicates the date when the medical
1. When your monitor is off, press and hold the [ ] button the display. Readings including stress, time of day, and/or how you determination of diastolic blood pressure. device was manufactured
for more than 10 seconds. If the morning weekly average is high In case of any of the below problems occur during measurement,
appear too high apply the wrist cuff, may affect your blood • This monitor is clinically investigated according to the
first check that no other electrical device is within 30cm. If the
• “oFF” appears on the display. (refer to section 1.3), the “ ” symbol or too low. pressure. Review sections 2.3 - 2.5 and chapter requirements of ISO 81060-2:2013. Battery
problem persists, please refer to the table below. • IP classification is degrees of protection provided by enclosures in
appears. 3.
accordance with IEC 60529. This monitor is protected against Direct current
Display/ Follow the instructions shown in the smart device,
Possible Cause Solution solid foreign objects of 12.5 mm diameter and greater such as a
Problem Any other or visit the “Help” section in the “OMRON finger, and against oblique falling water drops which may cause
3. Press the button repeatedly to display the average communication connect” app for further help. issues during a normal operation. Important information regarding Electro Magnetic Compatibility
for the previous weeks. Apply the wrist cuff (EMC)
issue occurs. If the problem still persists, contact your OMRON • This device has not been validated for use on pregnant patients.
The wrist cuff is not correctly, then take
Your monitor displays “-1 WEEK” for the previous week's retail outlet or distributor. The Bluetooth® word mark and logos are
applied correctly. another measurement. HEM-6232T-E manufactured by OMRON HEALTHCARE Co., Ltd. conforms to
average, to “-3 WEEK” for the oldest set of averages. About a wireless communication interference registered trademarks owned by the Bluetooth
• When the Bluetooth is Refer to section 2.4. Press the [START/STOP] button to turn the EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard.
appears or the This product operates in an unlicensed ISM band at 2.4 GHz. In the Further documentation in accordance with this EMC standard is available at SIG, Inc. and any use of such marks by
disabled, the following symbol
4. Press the [START/STOP] button to turn off your monitor. wrist cuff does Contact your OMRON
monitor off, then press it again to take a event this Product is used near other wireless devices such as www.omron-healthcare.com. Refer to the EMC information for HEM-6232T-E on OMRON HEALTHCARE Co., Ltd. is under
appears. Air is leaking from the measurement. If the problem continues, remove the website.
not inflate. retail outlet or Any other microwave and wireless LAN, which operate on the same license. Other trademarks and trade names are
Morning Weekly Average Calculation wrist cuff. all batteries and wait for 30 seconds. Then re- frequency band as this Product, there is a possibility that those of their respective owners.
distributor. problems occur.
This is the average for the measurements taken during the morning install batteries. interference may occur. Correct Disposal of This Product (Waste Electrical & Electronic
(4:00 - 9:59) between Sunday and Saturday. Only the first 3 The wrist cuff is Do not touch the wrist If the problem still persists, contact your OMRON If interference occurs, stop the operation of the other devices or Equipment)
Apple, the Apple logo, iPad and iPhone are trademarks of Apple
measurements taken in the morning between 4:00 - 9:59 will be overinflated exceeding cuff while taking a retail outlet or distributor. relocate this Product away from other wireless devices before Inc., registered in the U.S. and other countries. App Store is a
Note used to calculate the morning average for each day. appears 300 mmHg. measurement. attempting to use it. This marking shown on the product or its literature, indicates that it
should not be disposed of, with other household wastes at the end
service mark of Apple Inc., registered in the U.S and other
• To enable the Bluetooth, press and hold the [ ] button for Measurements of the morning
more than 2 seconds. “on” appears on the display. Sunday Monday Tuesday Wednesday Thursday Friday Saturday You move or talk during
8. Maintenance of its working life. countries.
Remain still and do not To prevent possible harm to the environment or human health from iOS is a trademark or registered trademark of Cisco in the U.S. and
• Your monitor will automatically turn off within 3 seconds after 4:00
a measurement. 10. Limited Warranty uncontrolled waste disposal, please separate this product from
the completion. 1 talk during a 8.1 Maintenance other types of wastes and recycle it responsibly to promote the
other countries and is used under license.
Vibrations disrupt a To protect your monitor from damage, please follow the directions Thank you for buying an OMRON product. This product is Android, Google Play and the Google Play logo are trademarks of
2 The first 3 measurements appears measurement. sustainable reuse of material resources.
3 measurement. below: constructed of high quality materials and great care has been taken Google LLC.
4
• Changes or modifications not approved by the manufacturer will in its manufacturing. It is designed to give you every satisfaction, Household users should contact either the retailer where they purchased this
Apply the wrist cuff provided that it is properly operated and maintained as described in product, or their local government office, for details of where and how they can Manufacturer OMRON HEALTHCARE Co., Ltd.
correctly, then take void the user warranty. return this item for environmentally safe recycling.
the instruction manual. Business users should contact their supplier and check the terms and conditions of 53, Kunotsubo, Terado-cho, Muko, KYOTO,
9:59 appears another measurement. This product is warranted by OMRON for a period of 3 years after
Caution the purchase contract. This product should not be mixed with other commercial 617-0002 JAPAN
Refer to section 2.4. the date of purchase. The proper construction, workmanship and waste for disposal.
Remain still and sit • DO NOT disassemble or attempt to repair this monitor or other
The pulse rate is not components. This may cause an inaccurate reading. materials of this product is warranted by OMRON. During this period
/ detected correctly. correctly during a of warranty OMRON will, without charge for labour or parts, repair or EU-representative OMRON HEALTHCARE EUROPE B.V.
appears measurement. replace the defect product or any defective parts. Scorpius 33, 2132 LR Hoofddorp,
If the “ ” symbol 8.2 Storage The warranty does not cover any of the following: THE NETHERLANDS
continues to appear, we Keep your monitor in the storage case when not in use. A. Transport costs and risks of transport. www.omron-healthcare.com
recommend you to • Store your monitor in a clean, safe location. B. Costs for repairs and / or defects resulting from repairs done by
Do not store your monitor: unauthorised persons. OMRON HEALTHCARE MANUFACTURING
consult with your
appears • If your monitor is wet. C. Periodic check-ups and maintenance. VIETNAM CO., LTD.
physician.
• In locations exposed to extreme temperatures, humidity, direct D. Failure or wear of optional parts or other attachments other than No.28 VSIP II, Street 2, Vietnam-Singapore
Production
Do not move your wrist, sunlight, dust or corrosive vapors such as bleach. the main device itself, unless explicitly warranted above. Industrial Park II, Binh Duong
Your wrist is moved up facility
then take another • In locations exposed to vibrations or shocks. E. Costs arising due to non-acceptance of a claim (those will be Industry-Services-Urban Complex,
and down during a charged for). Hoa Phu Ward, Thu Dau Mot City,
measurement.
appears measurement. 8.3 Cleaning F. Damages of any kind including personal caused accidentally or Binh Duong Province, Vietnam
Refer to chapter 3.
• Do not use any abrasive or volatile cleaners. from misuse.
Press the [START/ • Use a soft dry cloth or a soft cloth moistened with neutral soap to G. Calibration service is not included within the warranty. OMRON HEALTHCARE UK LTD.
STOP] button again. If clean your monitor and wrist cuff, and then wipe them with a dry Opal Drive, Fox Milne, Milton Keynes, MK15
The monitor is “Er” still appears, cloth. Should warranty service be required please apply to the dealer 0DG, UK
malfunctioned. contact your OMRON • Do not wash or immerse your monitor and wrist cuff in water. whom the product was purchased from or an authorised OMRON www.omron-healthcare.com
appears retail outlet or • Do not use gasoline, thinners or similar solvents to clean your distributor. For the address refer to the product packaging / literature
distributor. monitor and wrist cuff. OMRON MEDIZINTECHNIK
or to your specialised retailer. If you have difficulties in finding
HANDELSGESELLSCHAFT mbH
OMRON customer services, contact us for information.
Follow the instructions 8.4 Calibration and Service www.omron-healthcare.com Subsidiaries Konrad-Zuse-Ring 28, 68163 Mannheim,
shown in the “OMRON • The accuracy of this blood pressure monitor has been carefully GERMANY
The monitor cannot connect” app. If the tested and is designed for a long service life. Repair or replacement under the warranty does not give rise to any www.omron-healthcare.com
connect to a smart “Err” symbol still • It is generally recommended to have the unit inspected every two extension or renewal of the warranty period.
device or transmit data appears after checking years to ensure correct functioning and accuracy. Please consult OMRON SANTÉ FRANCE SAS
The warranty will be granted only if the complete product is returned
correctly. the app, contact your your authorised OMRON dealer or the OMRON Customer Service together with the original invoice / cash ticket issued to the
14, rue de Lisbonne, 93561 Rosny-sous-Bois
appears
OMRON retail outlet or at the address given on the packaging or attached literature. consumer by the retailer.
Cedex, FRANCE
distributor. www.omron-healthcare.com

Made in Vietnam