SSA 14&15/1996
DIN 19534
BS 4660, BS 5481
PrEN 1452-1
ISO R161/1
NAMAT lip seal fittings offer mechanical fixing joints and have
substantial advantages. Moreover, the revolution by the polymer
industry had no doubt played a vital role in the reduction of the
water and sewage networks costs. These advantages could be
summarized as follows:
Chemical Resistance.
uPVC fittings are resistant to corrosion that could be caused by
ground raw and mineral water. It is resistant to most solutions of
acids, alkalies, salts, oxidizing agents and major solvents that can
be dissolved in water. High resistance to abrasion is also an
important aspect.
Where special liquids are to be transported, please contact our
Technical Department for the appropriate advice.
Table. 1
Table .2
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 02.00.10* 40 111 3 3.2
SND 02.00.20 50 108 3 3.2
SND 02.00.30 75 131 3 3.2
SND 02.00.40 110 158 3 3.2
SND 02.00.50* 160 200 4 4.7
SND 02.00.60* 200 216 2 4.1
SND 02.00.70* 250 252 2 5.5
SND 02.00.80* 315 293 2 6.9
REPAIR COUPLING
Table .3
WALL
ORDERING SIZE DIMINUTION
THICKNESS
CODE mm K1 mm
mm
SND 03.00.10* 40 111 3.2
SND 03.00.20 50 108 3.2
SND 03.00.30 75 131 3.2
SND 03.00.40 110 158 3.2
SND 03.00.50* 160 200 4.7
SND 03.00.60* 200 216 4.1
SND 03.00.70* 250 252 5.5
SND 03.00.80* 315 293 6.9
BEND 15
Table .4
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 04.15.20 50 6 9 3.2
SND 04.15.30 75 6 11 3.2
SND 04.15.40* 110 12 19 3.2
SND 04.15.50* 160 13 19 4.7
SND 04.15.60* 200 15 23 4.1
SND 04.15.70* 250 19 30 5.5
SND 04.15.80* 315 23 38 6.9
BEND 30
Table .5
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 04.15.20 50 10 12 3.0
SND 04.15.30 75 11 15 3.0
SND 04.15.40* 110 17 21 3.0
SND 04.15.50* 160 24 30 3.6
SND 04.15.60* 200 30 38 4.5
SND 04.15.70* 250 37 49 6.1
SND 04.15.80* 315 47 61 7.7
BEND 45
Table .6
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 04.45.10* 40 15 21 3.2
SND 04.45.20 50 12 16 3.2
SND 04.45.30 75 23 29 3.2
SND 04.45.40 110 25 29 3.2
SND 04.45.50* 160 38 42 4.7
SND 04.45.60* 200 46 54 4.5
SND 04.45.70* 250 57 69 6.1
SND 04.45.80* 315 72 86 7.7
BEND 87½
Table .7
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 04.87.10* 40 37 39 3.2
SND 04.87.20 50 36 40 3.2
SND 04.87.30 75 62 67 3.2
SND 04.87.40 110 78 86 3.2
SND 04.87.50* 160 132 110 4.7
SND 04.87.60* 200 105 113 4.5
SND 04.87.70* 250 132 143 6.1
SND 04.87.80* 315 166 180 7.7
BRANCH 45
Table .8
Table .10
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K mm mm
SND 06.00.10* 40 43 2.0
SND 06.00.20* 50 45 2.0
SND 06.00.30* 75 59 3.0
SND 06.00.40* 110 41 3.0
SND 06.00.50* 160 53 3.6
SND 06.00.60* 200 64 4.5
SND 06.00.70* 250 95 6.1
SND 06.00.80* 315 100 7.7
Table .11
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K mm mm
SND 07.00.11 40X32* 28 2.0
SND 07.00.21 50X32* 26 2.0
SND 07.00.22 50X40* 21 2.0
SND 07.00.33 75X50* 45 3.2
SND 07.00.43 110X50* 50 3.2
SND 07.00.44 110X75* 35 3.2
SND 07.00.55 160X110* 34 3.6
SND 07.00.66 200X160* 29 4.5
SND 07.00.77 250X200* 36 6.1
SND 07.00.88 315X250* 48 7.7
ACCESS PIPE
Table .12
DIMINUTION WALL
ORDERING SIZE
THICKNESS
CODE mm K1 mm L mm mm
SND 12.00.40* 110 137 96 3.2
SND 12.00.50* 160 251 114 4.7
P-TRAP
Table .13
Instillation
When installing a push fit joint pipeline, the following steps must be
followed:-
1 • Cut the pipe (where necessary) at right angles to the axis
using a guided saw
2 • Use a rough file or chamfering tool to chamfer the
shortened pipe end to an angle approximately 15"
3 • Debur the chamfered ends
4 • Clean the out side of the spigot end and the inside of the
socket and check the position of the ring seal
5 • Mark the socket depth on the spigot end - deduct the
greater of 3 mm per meter of pipe length or 110 mm in
total
6 • Thinly lubricate the chamfered surface of the spigot end
with lubricants, don't use oil or grease
7 • Push the pipe spigot into the socket until the marking line
is reached
8 • Carefully support the pipe and gradually fill the trench with
bedding material
Trench Construction
1 • Trench Contour
2 • Trench Wrdth
The width of the trench at the crown of the pipe should be as
narrow as possible. The recommended trench should be at least
equal to the pipe outside diameter plus 300 mm.
3 • Trench Depth
The trench depth is the distance between the ground level and the
upper level of the pipe.
Trench depth ≥ 1 meter, or
Trench depth ≥ 1.5D, where D is the diameter of the pipe.
Trench depth
The minimum total cover should be not less than (ASTM F 690)
Requirements
3 • Hydrostatic load
(The load due to the presence of the aquifer)HL
Testing of installations
1 • Water Test
2 • Air Tightness test
Water Test
Make sure all outlets are closed except the highest level. Allow for a
water head of 1.2m using standard pipe. Fill the stand with water
and leave for a few hours. A drop of 50 mm is allowed in accordance
with values shown in the table below.
Table. 14
DURATION OF WATER TEST (MINS) FOR 50 MM WATER DROPS
2.5 5.0 7.5 10 15 20 25 40
MINIMUM LENGTH OF PIPE UNDER TEST (METER)
60 30 20 15 10 7.5 6.0 5
80 40 27 20 13 10.0 8 6.5
120 60 40 30 20 15.0 12 10.0
- 90 50 40 25 20.0 15 12.5
- 120 60 45 30 25.0 18 15
- - 80 60 40 30.0 24 30
- - 100 75 50 37.0 30 25
All the above figures are given in good faith and would not be part of any
contract or any warranty
AIR TIGHTNESS TEST
C-1 Apparatus
C-3 Procedure
Table. 15
Air test
DIA. OF PPE AIR TEST U TUPE WATER DROP MAX
DUR. (MINS) (MM)
75 1.5 25.0
110 2.0 25.0
160 3.0 25.0
200 4.0 25.0
250 4.5 25.0
315 5.0 20.0
400 6.0 20.0
The above figures are given in good faith and would not be part of
any contract or any warranty.