1/August, 2013/IRC:112-2011
to
IRC:112-2011 “Code of Practice for Concrete Road Bridges”
C
strength grade M60 for design purpose.
2 Clause 10.3.1 fywd = Design strength of web reinforcement fywd = Design strength of web reinforcement to
Notation used to resist shear limited to 0.8 fyk/gm. f yk
Page : 86 resist shear =
γm
taken as :
v1 = 0.6 for fck ≤ 80 MPa
= 0.9 –
f ck > 0.5 for fck > 80 MPa Delete
250
3 10.3.3.2: fywd = Design strength of web reinforcement fywd is the design strength of web reinforcement
Members used to resist shear limited to 0.8 fywk f yk
with vertical to resist shear =
γm
Shear
reinforcement
Page No. 91 v1 is a strength reduction factor for concrete v1 = v is a strength reduction factor for concrete
cracked in shear: cracked in shear given in Eq 10.6.
v1 = 0.6 for fck ≤ 80 MPa Delete
f ck
v1 = 0.9 – > 0.5 for fck > 80 MPa Delete
250
If v1 = v, then value of 0.67 fyk can be used. Delete
4 5.3.2.5 The bridge or any of its components shall The bridge or any of its components shall
Limit State of not loose its capacity to carry design loads not lose its capacity to carry design loads by
Fatigue by virtue of its materials reaching fatigue virtue of its materials reaching fatigue limits
limits due to its loading history. due to its loading history. For carrying out
Page No. 21
Note : For structures designed as per this fatigue verification, specialist literature may
Code, the effects of fatigue due to action of be referred.
live loads on concrete need not be taken into However, fatigue verification is not necessary
C
account, unless otherwise specified. for the following:
a) For Reinforced concrete structures when
the stress in the tensile reinforcement is
less than 300 MPa under Rare Combination
of Serviceability Limit State as against
0.8 fy specified in clause no. 12.2.2.
b) For prestressed concrete structures under
the frequent combination of action and
IR prestressing force, only compressive stresses
occur at the extreme concrete fibers, under
Serviceability Limit State.
fyk ---
(b) Hot Rolled/Heat Treated HYSD Steel (b) Hot Rolled/Heat Treated HYSD Steel