REPAIR & MAINTENANCE I Spider range pumps I

Maintenance instructions: After use (every time)


• To be used for all Spider range pumps.
• Wear full protective gear during maintenance !
• Always act according to the safety instructions as supplied with each pump !
Necessary equipment: soft cloth (also check list page 7).

Step 2
• Check coupler(s) and dust cap(s) for dirt and/or
oil leakage.
Step 1 • Clean coupler(s) with a clean and soft cloth, if neces-
• Check general condition of the pump. sary with water and soap.
• In case of electrical engine: check connection wire for • If necessary grease with WD40 or hydraulic oil.
damage. Replace if the insulation is damaged. • Check function coupler(s), see page 14.
• Storage: Place the pump in a horizontal position. • Reconnect loose dust cap(s) to coupler(s).

Step 3 Step 4
• Traditional couplers only: check if the lock ring on the • Check the rubber connection tube between the tank
outside of the swivel is still firmly attached. and flange. Replace if damaged or when leaking.
• Replace when broken, corroded, bend or missing. • Check if the clamps are still fastened.

Holmatro Rescue Equipment B.V. I P.O. Box 33 I 4940 AA Raamsdonksveer, the Netherlands I T +31 (0)162 589200 I rescue@holmatro.com I www.holmatro.com

© Holmatro 08-12
While the greatest care has been devoted to the content, it is possible that the information in this printed matter is incorrect or incomplete. N.V. Holmatro and its affiliated companies (hereafter: Holmatro)
cannot be held liable in any way for the consequences of activities undertaken on the basis of this printed matter. If you have any doubts about the correctness or completeness of the information, you
shall contact Holmatro. Nothing from this printed matter can be copied and/or made public in any way without he explicit authorization of Holmatro.
REPAIR & MAINTENANCE I Spider range pumps I Page 2 of 3

Max

Closed

Open

Step 5 Step 6
• Check hydraulic oil level, refill if necessary to the • Close the fuel line after use!
maximum level.
• Check fuel level, refill the fuel tank if necessary.

Note: Always refill fuel level to MAX.


Page 3 of 3

REPAIR & MAINTENANCE I Spider range pumps I

Maintenance instructions: After first 10 hours of use


• To be used for all Spider range pumps.
• Wear full protective gear during maintenance !
• Always act according to the safety instructions as supplied with each pump !
Necessary equipment: Open end / ring spanner No. 10 / 12, drainage container, funnel, engine oil (check list page 12).

Repeat step 1-6, of the after use maintenance recommendations.

Step 7 Step 8
• Replace engine oil trough dipstick opening. Collect the • Refill the engine with engine oil.
engine oil in an appropriate drainage container. • Make sure that the pump is in horizontal position when
checking the engine oil level.
• Alternative: Remove drain plug with an open end / ring • Fill the engine with engine oil to maximum level.
spanner to drain the oil.

Holmatro Rescue Equipment B.V. I P.O. Box 33 I 4940 AA Raamsdonksveer, the Netherlands I T +31 (0)162 589200 I rescue@holmatro.com I www.holmatro.com

© Holmatro 08-12
While the greatest care has been devoted to the content, it is possible that the information in this printed matter is incorrect or incomplete. N.V. Holmatro and its affiliated companies (hereafter: Holmatro)
cannot be held liable in any way for the consequences of activities undertaken on the basis of this printed matter. If you have any doubts about the correctness or completeness of the information, you
shall contact Holmatro. Nothing from this printed matter can be copied and/or made public in any way without he explicit authorization of Holmatro.