Sei sulla pagina 1di 24

PlanningXLSVer Plan Table Version SRAN13.

1
Start BSC SCTPID
BscSctpIdBase
Default value: 5000
Start SCTP port of a
BtsSctpPortBase base station
Default value: 8001
Number of TRXs
supported by each
BtsTrxPerSctp
SCTP of a base station
Default value: 12
Peer IP address of the
BtsOMCHPeerIP OM channel in a base
station

Peer IP mask of the OM


BtsOMCHPeerIPMask
channel in a base station

Baseline RAT during


SRANBaselineRAT SRAN data conversion
Default value: L

Work mode
WORKMODE
Default value: E1_UNBA
Version of the activated
GBTS evolution software
ActBTSSoftwareVersion (The GTMU evolution
software is of a special
V900 version.)
Name of the currently
reconstructed BSC in the
BSCNodeRedundancyBSCNa
BSC node redundancy
scenario
Version of the activated
GTMU SingleOM
reconstruction software
ActGTMUSoftwareVersion (The GTMU SingleOM
reconstruction software
is of a special V900
version.)

Note that specified values can be cleared by pressing Delete.


Description
GSM parameter, which is mandatory

GSM parameter, which is optional

GSM parameter, which is optional

GSM parameter, which is optional。If in GO


reconstruction scenario or a batch of reconstruction
scenario, the parameter is mandatory
GSM parameter, which is optional。If in GO
reconstruction scenario or a batch of reconstruction
scenario, the parameter is mandatory

Leave this parameter unspecified for single-mode


base stations.
Optional for an MBTS. The data is converted
according to the most recent mode if this parameter is
unspecified. In hybrid-MPT MBTS reconstruction
scenarios, the parameter must be set to SingleRAN.
Hint:
1. Only multiple MBTSs with the same baseline RAT
can be reconstructed in the same batch.
2. Set this parameter if the main control board or
transmission extension board of the baseline RAT
provides the transmission port in the reconstructed
co-MPT MBTS that uses co-transmission or two
BBUs. The BBUs can be interconnected.
3. When this parameter is used to determine the data
of which RAT is used during data conversion, a
warning is prompted if the conversion can affect
transmission QoS or transmission routes.

Mandatory when GSM uses E1/T1 transmission

GSM evolution, mandatory

Mandatory in the BSC node redundancy scenario

Mandatory when the GTMU supports SingleOM


n. You are
Set advised to set
ConvertFl this
ag to Yes parameter
if data according to
NE name
conversio the data plan.
Mandatory if Mandatory if after data
Reserved n is Mandatory if If this
data of a data of a conversion.
for future required data of an parameter is
GBTS or an NodeB or an If this
expansion in this eNodeB or an unspecified,
MBTS that MBTS that parameter is
, which reconstru MBTS that the local IP
contains a contains a unspecified,
can be ction. contains an address of
GBTS is to NodeB is to the NE name
unspecifie Note that eNodeB is to the OM
be be is
d specified be converted channel is
converted. converted. automaticall
values can automatically
ScenarioI ConvertFl
be cleared
y generated. OMCHLocalI
generated.
BtsName NodeBName eNodeBName SRANName
d ag
by P
This
pressing parameter
Delete. does not need
to be set for
multimode
reconstructio
n.

Scenario
ID NE name Local IP
Default Conversio NodeB eNodeB after data address of an
value: 0 n ID GBTS name name name conversion OM channel
Optional for eGBTS
Mandatory
reconstruction. You
when GSM
are advised to set
uses
this parameter
Ethernet Mandatory if Optional. If
according to the
transmissio GSM uses IP over this
data plan. If this
n. This FE/GE or E1 parameter is
parameter is
parameter transmission unspecified,
unspecified, the
can be Mandatory when with E1 backup, the default
local IP address Parameters involved in the GTMU aban
unspecified IP over E1 is used and optional in priorities are
mask of the OM
if GU or GL GU or GL FE co- used for
channel is
co- transmission reference
automatically
transmissio scenarios with E1 clock
generated. This GTMU
OMCHLocalIPMas
parameter does not
n through backup sources. UMPTSlo
NextHop
backplane IPHCSUBOPT IPoE1OMIP ClkSrc Abandon
kneed to be set for t
interconnect ed
multimode
ion is used.
reconstruction.

Whether Slot
to number of
abandon the GSM
the main
GTMU for control
GSM board
OM IP address Base station after data after data
Gateway IP in IP over E1 clock data conversio conversio
Local IP address address of IPHC suboption transmission conversion n n
mask of an OM the base Default value: scenarios with Default Default Default
channel station DISABLE E1 backup value: NULL value: NO value: 7
in position or is
powered off, the
working standard
change fails.)
If the UMPT of the non-
baseline RAT is not
inherited, the UMPT will
not
Usingbetwo
changed
UMPT to a
boards
ers involved in the GTMU abandoning scenario secondary
after co-MPT board or Two BBUs combined into one
standby board during
reconstruction
the reconstruction. You
CPRI fiber optic cables on the to- can manually change it
be-abandoned
GTMU CPRI Move GTMU need to be to a secondary board by MultiBBUCombFl MultiBBUCombTempl
adjusted. Adjustment of the CPRI RetainPeerMPT
running MML
TemplateName ag ateName
fiber optic cables is specified commands or use it for
using a template. If adjustment is other purposes.
required, set this parameter to the
corresponding template name. If If this parameter is
adjustment is not required, leave unspecified, the main
this parameter unspecified. control board of the
Ensure that the template exists in non-baseline RAT is
the inherited.
MultiCpriChainMoveTemplate If the peer RAT uses a Indicates whether
sheet before setting this GTMU, WMPT, or two BBUs are
parameter to a template name (in LMPT, the value of this combined into
column A of the parameter does not one in the Name of the template
MultiCpriChainMoveTemplate affect the scenario. used for BBU
sheet). reconstruction. Default value: No combination
r to
GTMUb
or GTMUc
according
to site
condition
s. If this
paramete
GTMU
r is
SingleOM
incorrectl
y set,
configura
tions fail
MPTType
to take
effect
after data
conversio
n due to
the
difference
in TRX
specificat
ions
between
the
GTMUb
and
GTMUc.
473575283.xls Confidentiality

GTMU Dest Dest Dest


GTMU
TemplateName CPRIPort UBRI/UBBP UBRI/UBBP UBRI/UBBP
CPRIPort
Need CpriMux BrdType Slot CPRIPort

0 NO UBRI 1 0
1 NO UBRI 1 1
2 NO UBRI 1 2
Default_Template
3 NO UBRI 1 3
4 NO UBRI 1 4
5 NO UBRI 1 5

05/01/2020 Huawei Proprietary and Confidential Page 7 of 24


473575283.xls Confidentiality

This template specifies CPRI adjustment in the GTMU abandoning scenario.

Guideline:
1. Each TemplateName parameter value corresponds to one piece of CPRI adjustment
information for a GTMU in a base station during co-MPT reconstruction. The number of rows where
this parameter occupies indicates the number of CPRI fiber optic cables to be adjusted. In addition,
GTMU CPRI Move TemplateName in the SitePlanning sheet needs to be set to the value of
TemplateName (column A).
2. You are advised to set TemplateName to base station names, which prevents data conversion
errors due to same TemplateName values. Exercise cautions when multiple co-MPT
reconstruction sites share one TemplateName value.
3. Each piece of CPRI adjustment information includes the following five items: GTMU CPRIPort,
GTMU CPRIPort Need CpriMux, Dest UBRI/UBBP BrdType, Dest UBRI/UBBP Slot, and Dest
UBRI/UBBP CPRIPort. All these items need to be specified. If no board is installed in the slot
specified by Dest UBRI/UBBP Slot, a UBRI or UBBP will be added during co-MPT reconstruction.
4. Default_Template is a default template, which is used when all CPRI cables on the GTMU are
moved to a newly added UBRI in slot 1 and the GTMU is abandoned.

05/01/2020 Huawei Proprietary and Confidential Page 8 of 24


Configuration Information (Do not change the values in this row.) 8 13 2 8
Guidelines (note that specified values can be cleared by pressing Delete):
1. Among the existing templates, find the one for which the template scenar
actual scenario has the same BBU configurations as a template scenario, c
base station in the Site Planning sheet.
2. Set the boards in the two BBUs before combination.
3. Set the boards in the BBU after combination. (Note that board slot assign
4. If the location of a board is changed, set the corresponding cell in column
example, set a cell to BBU_G-6 which indicates that the board is originally l
Remarks:
After combination, the slot numbers of some boards are changed. (For exam
connected to a CPRI cable before combination. After combination, since an
this case, the WBBP installed in slot 2 before combination is moved to slot
must be manually specified to facilitate configuration mapping. For example
configured for the WBBP installed in slot 3 before combination must be dete
after combination.
Guideline Note that if a GTMU is abandoned after combination, a UBBP or UBRI need
example, a UBRI is installed in slot 1 and processes CPRI data instead of t
H or M to BBU_G-1.
In addition, note that the boards used in the BBU after combination (under t
For a clearer view, you can use different colors to identify the boards from d

Template Name Description Co-MPT BBU


now
BBU_G
0 4
1 5
2 GTMU 6
G、UL->G*U*L 3 7 ----->>
G+UL_DEFAULT BBU3900-BBU3900 ----->>
BBU_UL ----->>
0 4 ----->>
1 5
2 LBBP UMPT 6
3 WBBP WMPT 7

now
BBU_GU
0 4
1 5
2 WBBP GTMU 6
GU、L->G*U*L 3 WBBP WMPT 7 ----->>
GU+L_DEFAULT
BBU3900-BBU3900 ----->>
BBU_L ----->>
0 4 ----->>
GU、L->G*U*L
GU+L_DEFAULT
BBU3900-BBU3900

1 5
2 LBBP UMPT 6
3 7

now
BBU_GL
0 4
1 5
2 LBBP GTMU 6
GL、U->G*U*L 3 UMPT 7 ----->>
GL+U_DEFAULT
BBU3900-BBU3900 ----->>
BBU_U ----->>
0 4 ----->>
1 5
2 WBBP 6
3 WBBP WMPT 7

now
BBU_U
0 4
1 5
2 WBBP 6
U、L->U*L BBU3900- 3 WBBP WMPT 7 ----->>
U+L_DEFAULT
BBU3900 ----->>
BBU_L ----->>
0 4 ----->>
1 5
2 LBBP UMPT 6
3 7

now
BBU_G
0 4
1 5
2 GTMU 6
G、U->G*U BBU3900- 3 7 ----->>
G+U_DEFAULT
BBU3900 ----->>
BBU_U ----->>
0 4 ----->>
1 5
2 WBBP 6
3 WBBP WMPT 7

now
BBU_G
0 4
1 5
2 GTMU 6
G、L->G*L BBU3900- 3 7 ----->>
G+L_DEFAULT
BBU3900 ----->>
G、L->G*L BBU3900-
G+L_DEFAULT
BBU3900
BBU_L ----->>
0 4 ----->>
1 5
2 LBBP UMPT 6
3 7

now
BBU_G
0 4
1 5
2 GTMU 6
G+UL_AND_GTMU_ABANDONE G、UL->G*U*L 3 7 ----->>
D_DEFAULT BBU3900-BBU3900 ----->>
BBU_UL ----->>
0 WBBP 4 ----->>
1 5
2 LBBP UMPT 6
3 WBBP WMPT 7
cleared by pressing Delete):
for which the template scenario and the actual scenario are most similar in BBU configurations. If the
ons as a template scenario, copy the template name (in column A) to the cell of the corresponding

bination.
n. (Note that board slot assignment must follow related rules after adjustment.)
e corresponding cell in column H or M to specify where the board is located before combination. For
es that the board is originally located in slot 6 of the BBU serving GSM.)

oards are changed. (For example, in the following figure, the WBBP in slot 3 of BBU_GU is
n. After combination, since an LBBP has been configured in slot 3, the WBBP is moved to slot 2. In
combination is moved to slot 0 after combination.) The slot numbers before and after combination
uration mapping. For example, which WBBP will inherit the data (including CPRI interface data)
ore combination must be determined as well as the slot number of the WBBP that inherits the data

nation, a UBBP or UBRI needs to be added to take the place of the GTMU for CPRI processing. For
esses CPRI data instead of the abandoned GTMU. In this case, set the corresponding cell in column

BU after combination (under to be) are those used in the two BBUs before combination (under now).
s to identify the boards from different BBUs. The following figure shows an example.

Co-MPT BBU Solution


to be
BBU_G
0 4
1 5
2 6
3 7

BBU_UL
0 4
1 5
BBU_UL-2 2 LBBP GTMU 6 BBU_G-6
BBU_UL-3 3 WBBP UMPT 7 BBU_UL-6

to be
BBU_GU
BBU_GU-2 0 WBBP 4
1 5
BBU_L-2 2 LBBP GTMU 6 BBU_GU-6
BBU_GU-3 3 WBBP UMPT 7 BBU_L-6

BBU_L
0 4
1 5
2 6
3 7

to be
BBU_GL
BBU_U-2 0 WBBP 4
1 5
BBU_GL-2 2 LBBP GTMU 6 BBU_GL-6
BBU_U-3 3 WBBP UMPT 7 BBU_GL-7

BBU_U
0 4
1 5
2 6
3 7

to be
BBU_U
BBU_U-2 0 WBBP 4
1 5
BBU_L-2 2 LBBP UMPT 6 BBU_L-6
BBU_U-3 3 WBBP WMPT 7 BBU_U-7

BBU_L
0 4
1 5
2 6
3 7

to be
BBU_G
0 4
1 5
2 6
3 7

BBU_U
0 4
1 5
BBU_U-2 2 WBBP GTMU 6 BBU_G-6
BBU_U-3 3 WBBP UMPT 7 BBU_U-7

to be
BBU_G
0 4
1 5
2 6
3 7
BBU_L
0 4
1 5
BBU_L-2 2 LBBP GTMU 6 BBU_G-6
3 UMPT 7 BBU_L-6

to be
BBU_G
0 4
1 5
2 6
3 7

BBU_UL
BBU_UL-0 0 WBBP 4
BBU_G-1 1 UBRI 5
BBU_UL-2 2 LBBP WMPT 6 BBU_UL-7
BBU_UL-3 3 WBBP UMPT 7 BBU_UL-6
MML GUI
Descriptio Paramete Default Mandator
Paramete Parameter ID Value Example User
n r Type Value y or Not
r Type Range

BscSctpIdBase Start BSC


SCTP link Interval 0~42949
ID type 5000 67294 Yes 5000 BSC
Start
SCTP
port
BtsSctpPortBase number
of a base Interval 1024~65
station type 8001 535 No 8001 BSC

Number
of TRXs
supported
BtsTrxPerSctp by each
SCTP link
of a base Interval
station type 12 1~18 No 12 BSC/BTS

Peer IP
address
BtsOMCHPeerIP of an OM
channel Valid IP
in a base Valid IP addresse 10.10.10.
station address s Yes 10 BSC/BTS

Peer IP
address
BtsOMCHPeerIPMa mask of
sk an OM
channel Valid IP
in a base Valid IP addresse 255.255.
station address s Yes 255.0 BSC/BTS

Global SRANBaselineRAT
paramete Baseline
r RAT
during
SRAN U,
data L,
conversio Enumerat SingleRA
n ion type L N No L SRAN

WORKMODE E1_UNB
A,
E1 work Enumerat E1_UNB E1_BA, E1_UNB
mode ion type A T1 No A BTS
ActBTSSoftwareVer Version
sion of the BTS3900
activated 1~255 V900R01
GBTS String character 0C00SPC
software
Name of type s No 010 BTS
the
currently
reconstru
cted BSC
BSCNodeRedundan in the
cyBSCName BSC
node
redundan 1~64
cy String character
scenario type s No Bxxx BSC

Version
of the
activated
ActGTMUSoftwareV GTMU
ersion SingleOM BTS3900
reconstru 1~255 V900R01
ction String character 0C00SP1
software type s No 00 BTS
Scenario Interval BSC/BTS
ScenarioId
ID type 0 0~65535 No 0 /SRAN

ConvertFlag
Conversi String Yes BSC/BTS
on flag type No Yes /SRAN

BtsName 1~64
GBTS String character BSC/BTS
name type s No GSxxx /SRAN

NodeBName 1~64
NodeB String character BSC/BTS
name type s No NBxxx /SRAN

eNodeBName 1~64
eNodeB String character BSC/BTS
name type s No LTEyyy /SRAN

SRANName NE name
after data 1~64
conversio String character BSC/BTS
n type s No Sxxx /SRAN

OMCHLocalIP Local IP
address Valid IP
of an OM Valid IP addresse
channel address s No 10.1.1.10 BSC/BTS
Local IP
address
OMCHLocalIPMask mask of Valid IP
an OM Valid IP addresse 255.255.
channel address s No 255.0 BSC/BTS

NextHop
Gateway
IP
address
of the Valid IP
base Valid IP addresse 10.140.1 BTS/SRA
station address s No 41.1 N

IPHCSUBOPT DISABLE
IPHC Enumerat ,
suboption ion type DISABLE ENABLE No ENABLE BTS
OM IP
address
in IP over
E1
IPoE1OMIP transmiss
ion
scenarios Valid IP
with E1 Valid IP addresse
backup address sGPS, No 10.1.2.10 BTS
IPCLK,
SYNCET
H,
LINECLK,
TOD,
ClkSrc
Referenc BITS,
e clock SYNCET
source of H+IPCLK
the base Enumerat ,
station ion type NULL NULL No NULL SRAN
abandon
the
GTMU for
GTMU Abandoned GSM
after data
conversio Enumerat NO,
n ion type NO YES No YES BTS
number
of the
GSM
main
UMPTSlot control
board
after data
conversio Interval
n type 7 6~7 No 7 BTS
Site-level
paramete
r
not in
position
or is
powered
off, the
Site-level working
CPRI
paramete standard
fiber optic
r change
cables on
fails.)
the to-be-
If the
abandon
UMPT of
ed GTMU
the non-
need to
baseline
be
GTMU CPRI Move RAT is
adjusted.
TemplateName not
Adjustme
inherited,
nt of the
the
CPRI
UMPT
fiber optic
will not be
cables is
changed
specified 1~64 GBTSXX
to a
using a String character X_NODE BTS/SRA
secondar
template. type s No BYYY N
y board
GTMU
or
CPRI
standby
adjustme
Template
board
nt 1~64 GBTSXX
Name
during
template the Character character X_NODE BTS/SRA
reconstru
name strings s No BYYY N
ction. You
can
Source
manually
CPRI port
GTMU change
number it
CPRIPort to abe
secondar
adjusted Interval
y
onboard
the value BTS/SRA
by
GTMU type 0~5 No 1 N
the
running
source
MML
GTMU CPRI port
command
CPRIPort toor
s beuse it
Need adjusted
for other
CpriMux needs
purposes. Enumerat NO, BTS/SRA
MultiCpri MUX ed type NO YES No NO N
ChainMo If this
veTempla Move
paramete the
te Dest CPRI
r is
template UBRI/UB fiber optic
unspecifi
BP cables
ed, the to
BrdType the
maintarget Enumerat UBRI, BTS/SRA
boards
control ed type UBRI UBBP No UBRI N
board of
Move
the non- the
Dest CPRI
baseline
UBRI/UB fiber
RAT optic
is
BP Slot cables
inherited. to Interval
the
If thetarget value BTS/SRA
slots
peer RAT type 0~5 No 2 N
uses a
Move
GTMU,the
CPRI
WMPT,
Dest fiber optic
UBRI/UB or LMPT,
cable
the to
value
BP the CPRI
CPRIPort of this
ports
paramete on Interval
the target
r does not value BTS/SRA
board.
affect the type 0~5 No 3 N
reconstru Enumerat NO, BTS/SRA
RetainPeerMPT
ction. ion type YES YES No YES N
Whether
two BBUs
are
MultiBBUCombFlag combined
into one
in the Enumerat Yes,
scenario ion value No No No Yes SRAN

MultiBBUCombTem
plateName Name of
the
template
used for
BBU 1~255
combinati Character character G+UL_D
on string s NO EFAULT SRAN

MPTType

Type of
the main UMPT,
control Enumerat GTMUb,
board ion value GTMUc NO GTMUb BTS
Remarks

Mandatory
Set this parameter according to the configuration plan.
Note: The generated SCTP link ID cannot be the same as any SCTP link ID
existing on the BSC. You can run the LST SCTPLNK command on the
BSC to query the existing SCTP link IDs.

Optional. The default value takes effect if it is unspecified.


Set this parameter according to the configuration plan.

Optional for a GBTS. The default value takes effect if it is unspecified.


In most cases, set this parameter to the default value 12.
The system generates SCTP links with the quantity determined by this
parameter.

GSM parameter, which is optional


U2000 IP address of an OM channel in the base station
In the GO reconstruction or batch reconstruction scenario, this parameter is
mandatory.

GSM parameter, which is optional


U2000 IP address mask of an OM channel in the base station
In the GO reconstruction or batch reconstruction scenario, this parameter is
mandatory.

Leave this parameter unspecified for single-mode base stations.


Optional for an MBTS. The data is converted according to the most recent
mode if this parameter is unspecified. In hybrid-MPT MBTS reconstruction
scenarios, the parameter must be set to SingleRAN.
Hint:
1. Only multiple MBTSs with the same baseline RAT can be reconstructed in
the same batch.
2. Set this parameter if the main control board or transmission extension board
of the baseline RAT provides the transmission port in the reconstructed co-
MPT MBTS that uses co-transmission or two BBUs. The BBUs can be
interconnected.
3. When this parameter is used to determine the data of which RAT is used
during data conversion, a warning is prompted if the conversion can affect
transmission QoS or transmission routes.

Optional. It is mandatory when GSM uses E1/T1 transmission.


E1 unbalanced mode and E1 balanced mode correspond to different E1
impedances. E1 unbalanced mode corresponds to impedance of 75 ohms, and
E1 balanced mode corresponds to impedance of 120 ohms.
This parameter is unavailable for the GBTS. The work mode is determined by
the DIP switch. After reconstruction to a co-MPT base station, this parameter
takes effect instead of the DIP switch.
GTMU evolution software version, which is optional. Leave this parameter
unspecified if the GTMU is abandoned or GSM is not involved. Set this
parameter in other scenarios.
The GTMU evolution software is of a special V900 version, such as
BTS3900V900R008C00SP010. In the GTMU evolution scenario, the U2000
must be informed of the GTMU evolution software version to be used in PnP
tasks. If the GTMU evolution software version is unspecified, PnP tasks will fail.
Then, data conversion needs to be performed for a second time, which causes
a waste of time and manpower.

Optional. If the BSC name is unspecified, the CME uses the current processing
mode. That is, the CME searches for the BSC to be reconstructed based on the
GBTS name.
If the BSC name is specified, all GBTSs to be reconstructed must belong to this
BSC.

GTMU SingleOM reconstruction software version, which is optional. The GTMU


SingleOM reconstruction software is of a special V900 version, such as
BTS3900V900R010C00SP010.
If the GTMU supports SingleOM, the U2000 must be informed of the GTMU
SingleOM reconstruction software version to be used in PnP tasks. If the
GTMU SingleOM reconstruction software version is unspecified, PnP tasks will
fail. Then, data conversion needs to be performed for a second time, which
causes a waste of time and manpower.

Reserved for future expansion, which can be unspecified


Indicates whether the base station in the table requires data conversion.
If this parameter is set to Yes, data of the base station will be converted. If this
parameter is unspecified, the base station data will not be converted.
You can clear Yes by pressing Delete to disable data conversion.
Mandatory if data of a GBTS or an MBTS that contains a GBTS is to be
converted, which is manually configured.
The name cannot contain any of the following special characters: , ; = " ' \ / : * ?
< > | @ # ! % ^ & * [ ].
Mandatory if data of a NodeB or an MBTS that contains a NodeB is to be
converted, which is manually configured.
The name cannot contain any of the following special characters: , ; = " ' \ / : * ?
< > | @ # ! % ^ & * [ ].
Mandatory if data of an eNodeB or an MBTS that contains an eNodeB is to be
converted, which is manually configured.
The name cannot contain any of the following special characters: , ; = " ' \ / : * ?
< > | @ # ! % ^ & * [ ].
NE name after data conversion. If this parameter is unspecified, the NE name
is automatically generated based on the SRANBaselineRAT parameter value.
If SRANBaselineRAT is unspecified, the NE name of the most recent RAT is
used. The name cannot contain any of the following special characters: , ; = " ' \
/ : * ? < > | @ # ! % ^ & * [ ]. When the PnP task is started, the NE name of the
baseline RAT will be automatically changed to the value of this parameter.
(This name is planned by users. If users do not plan this name, the NE name of
the baseline RAT is used.)

Optional for eGBTS reconstruction. You are advised to set this parameter
according to the data plan. A newly planned local IP address of an OM channel
must be a logical IP address instead of an interface IP address.
If this parameter is unspecified for eGBTS reconstruction, the BTS IP address
of the GBTS is automatically used.
Leave this parameter unspecified for multimode reconstruction.
Optional for eGBTS reconstruction. You are advised to set this parameter
according to the data plan.
If this parameter is unspecified for eGBTS reconstruction, the BTS IP address
mask of the GBTS is automatically used.
Leave this parameter unspecified for multimode reconstruction.

Optional. It is mandatory if GSM uses Ethernet transmission. This parameter


specifies the next-hop IP address of the Ethernet port in the base station. This
parameter can be unspecified if GU co-transmission through backplane
interconnection is used or if GL co-transmission through backplane
interconnection is used without E1 backup. This parameter must be specified if
GL co-transmission through backplane interconnection is used with E1 backup.
If the Abis interface applies layer 2 networking, this parameter is set to the
interface IP address of the board where the BSC IP address is configured. If
co-transmission is not used or co-transmission through panel interconnection is
used, this parameter is set to the next-hop IP address configured on the GSM
side and this IP address must on the same network segment as the BTS device
IP address but different from the BTS IP address. If GL co-transmission
through backplane interconnection is used with E1 backup, this parameter is
set to the next-hop IP address of the port of the baseline RAT.
Mandatory when IP over E1 is used
(If the base station is directly connected to the controller through IP over E1,
set this parameter to DISABLE. If the base station is connected to a router
through IP over E1, set this parameter to ENABLE. If the base station is
connected to an upper-level base station through IP over E1, set this
parameter to DISABLE.)

Mandatory if GSM uses IP over FE/GE or E1 transmission with E1 backup, and


optional in GU or GL FE co-transmission scenarios with E1 backup

Optional. This parameter is used for clock data conversion. The default value
NULL indicates that the default reference clock source priorities (GPS >
SYNCETH+IPCLK > IPCLK > SYNCETH > LINECLK > TOD > BITS) take
effect. You are advised to run the SET CLKMODE command to configure this
parameter for the hybrid reference clock sources.

Optional. If this parameter is unspecified, the default value takes effect. Set this
parameter to YES in the GTMU abandoning scenario. Set this parameter to NO
in the GTMU evolution scenario.

Optional. This parameter is used in the GTMU abandoning scenario. The


default value takes effect if this parameter is unspecified.
Mandatory in the GTMU abandoning scenario. Adjustment of CPRI fiber optic
cables on the GTMU is specified using a template. Set this parameter to the
corresponding template name. Specify the template in the
MultiCpriChainMoveTemplate sheet.

GTMU CPRI adjustment template name, which is mandatory in the GTMU


abandoning scenario

Number of the port from which a CPRI fiber optic cable is removed, which is
mandatory in the GTMU abandoning scenario

Mandatory in the GTMU abandoning scenario. This parameter specifies


whether to use CPRI MUX due to port insufficiency when the dual-star topology
is used before GU/GL/GU+L/GL+U co-MPT reconstruction. If this parameter is
set to YES, CPRI MUX is used. If this parameter is set to NO, CPRI MUX is not
used. If this parameter is unspecified, the default value takes effect.
The default value is NO.

Type of the board to which the CPRI fiber optic cable is to be moved from the
GTMU, which is mandatory in the GTMU abandoning scenario. If this
parameter is unspecified, the default value takes effect.
The default value is UBRI.

Number of the slot housing the board to which the CPRI fiber optic cable is to
be moved from the GTMU, which is mandatory in the GTMU abandoning
scenario

Set this parameter to NO if you need to remove the main control board of a
Number of theRAT.
non-baseline port to which the CPRI fiber optic cable is to be moved from the
GTMU, which is
Set this parametermandatory
to YES ifinyou
theneed
GTMU abandoning
to reserve scenario
the main control board of the
non-baseline RAT and convert this board to a secondary board or standby
board.
Optional. This parameter must be set to Yes when two BBUs are to be
combined into one.

Since there are many scenarios where two BBUs are combined into one, select
a template from the MultiBBUCombTemplate sheet and set this parameter to
the template name (column A in the MultiBBUCombTemplate sheet).
If you want to define a new template, select a most similar template and copy it
to the end of the MultiBBUCombTemplate sheet (note that you can leave a
maximum of 12 blank rows between two templates). Then, modify the template,
rename it, and set this parameter to the name of the new template.
When modifying the template, do not change the number of rows the template
occupies. Change the cell values by selecting values from drop-down menus
but do not delete any cells.

Type of the main control board used after reconstruction, which is optional. If
this parameter is unspecified, the default value UMPT takes effect.
Note that the GTMUb/GTMUc SingleOM scenario and the GTMU abandoning
scenario are mutually exclusive.
Notice: In the GTMUb/GTMUc SingleOM scenario, set this parameter to
GTMUb or GTMUc according to site conditions. If this parameter is incorrectly
set, configurations fail to take effect after data conversion due to the difference
in TRX specifications between the GTMUb and GTMUc.