Sei sulla pagina 1di 2

SIPROTEC 6MU85

Merging Unit

www.siemens.com/6MU85

Description
The new SIPROTEC 6MU85 Merging Unit based on the
flexible SIPROTEC 5 system has been designed for conven-
tional and non-conventional instrument transformers
(LPITs)* and digitalizes all primary data close to the pro-
cess. SIPROTEC 5 process bus provides versatile solutions
and migration concepts for new and existing systems.

Main function Merging Unit,


Breaker functions, SIPROTEC 6MU85
Backup protection functions, Functions
Additional functions
Merging Unit
Communication Up to 4 sampled measured value streams
• Per ETH-BD-2FO Ethernet module 1 or 2*Sampled
according IEC 61850-9-2LE or IEC 61850-
Measured Value (SMV) streams
9-2 / IEC 61869 flexible streams
- up to 32 analog values in any combination of CTs
Hardware flexi- Flexibly adjustable and expandable I/O and VTs
bility quantity structure within the scope of the or
modular SIPROTEC 5 system; 1/6 expan- - 4x CTs, 4x VTs (IEC 61850-9-2LE)
sion modules can be added.
• Up to 4 ETH-BD-2FO modules possible
Housing width 1/3 × 19 inches to 2/1 × 19 inches • Reliable and redundant data transmission via PRP pro-
As standard
tocol
Conformal Coating
• IEC 61869-9, IEC 61869-13 compliant
Applications
• IEC 61850-8-1 GOOSE, MMS and Merging Unit proto-
Merging Unit for col on the same Ethernet module
• Analog and digital feeder values • Sample and date/time synchronization via IEEE
• Central Merging Unit for transformers 1588v2/PTP

• Central protection • Redundant power supply

• Bay units for distributed busbar protection • Extended temperature range (-40 ºC to 70 ºC)

• Fault recorder for process bus


Merging Unit functionality is also available for all modular
• Centralized synchrocheck SIPROTEC 5 protection devices.
Efficient and modular

IEC 61850-9-2, IEC 60870-5-103, IEC 60870-5-104,


Breaker functions
Modbus TCP, DNP3 serial and TCP, PROFINET IO)
• Control with switchgear interlocking
• Serial protection data communication via optical
• Circuit-breaker failure protection (50BF) fibers, two-wire connections and communication
networks (IEEE C37.94, and others), including auto-
• Circuit-breaker wear monitoring
matic switchover between ring and chain topology
• Switching statistics
• Extensive cyber security functionality, such as role-
• Point on wave switching (PoW) based access control (RBAC), protocolling security-
related events or signed firmware
• Trip-circuit supervision (74TC)
• Simple, quick and secure access to device data via a
• Automatic reclosing (79)
standard Web browser – without additional software
• Synchrocheck (25) Benefits
Backup protection functions
• Adaptable to multiple CT, VT, LPIT* inputs
• Non-directional overcurrent protection (50/51,
• Scalable number of binary inputs and outputs
50N/51N)
• Expandable by a 2nd row
• Directional overcurrent protection (67/67N)
• Direct “high speed” tripping of circuit breaker < 1 ms
• Overvoltage and undervoltage protection (27/59)
• Collection of additional data (temperature, pressure,
Additional functions
tap changer positions, …)
• Phasor Measurement Unit (PMU) for synchrophasor
• Cyber security in accordance with NERC CIP and BDEW
measured values and IEEE C37.118 protocol
Whitepaper requirements
• Arc protection
• Highest availability even under extreme environmen-
• Auxiliary functions for simple tests and commissioning tal conditions by “conformal coating“ of electronic
boards
• Temperature measurement via Thermobox TR1200
(7XV5662-6AD10 or 7XV5662-8AD10)
• 4-20 mA transducer inputs for various analog process
values, e.g pressure, tap-changer position
*) in preparation
Communication LPIT = Low Power Instrument Transformer

• Pluggable communication modules, usable for


different and redundant protocols (IEC 61850-8-1,

For all products using


security features of
Siemens 2020 For the U.S. published by OpenSSL, the
Siemens Industry Inc. following shall apply:
Smart Infrastructure
Digital Grid 100 Technology Drive This product includes
software developed
Humboldtstrasse 59 Alpharetta, GA 30005
by the OpenSSL Pro-
91459 Nuremberg, United States ject for use in the