Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Features
Stable, linear, and accurate density output signal even S-Mass Model S200
by changes in product temperature, pressure, density,
flow rate, or viscosity
Serial data link to flow controller
Easy Installation, mounts in line with process piping.
No straight pipe runs required upstream or downstream.
Can be installed in vertical or horizontal piping
Patented S-shape tubes for maximum flow sensitivity
All stainless steel
Factory pre-calibrated
User PC programmable for setup, tune, and calibra-
tion
Flanges and end connections of various types, sizes,
and ratings are available for the flow sensor
Flow through indication Figure 1 — Tube Deflections Due to Coriolis Forces
Output A
Principle of Operation
Amplitude
Output B
S-Mass meters precisely determine mass flow by meas-
uring the effects of Coriolis forces on a pair of S-tubes,
which are electromagnetically vibrated. Time
The measurement principle is based on a variation of φ
Newton’s Second Law of Motion: Phase Shift
(Proportional to
Force = Mass x Acceleration Mass Flow Rate)
As fluid (V) proceeds through the S-tubes, it experi-
ences an acceleration transverse to the direction of Figure 2 — Motion Sensor Outputs with Flow
flow, and Coriolis forces (Fc) result. The Coriolis force
causes the displacement of the vibrating tubes to be-
come slightly distorted or out of phase (Figure 1).
Motion sensors, placed symmetrically about the mid-
points, generate electrical signals with a relative phase
shift that is proportional to mass flow (Figure 2). These
electrical signals are processed in the Micro-Pak trans-
mitter module to provide various outputs.
ANSI Flanges
Specifications
Type: Patented S-shaped flow path, vibrating element Maximum W.P. psi (kPa) 2
Model
Function: Convert density to an equivalent frequency
Sizes Class 150 Class 300 Class 600
(linear); provide communication density value; indicate
flow circulation 1", 1-1/2", 230 600 1200
S100
Accuracy: <0.0002 g/cc at calibration condition, 2" (1586) (4137) (8274)
<0.0005 g/cc limited condition range (approval certi- 230 600 800
fied) S200 2", 3", 4"
(1586) (4137) (5516)
Repeatability: < 0.0002 g/cc
Density Range: 0.251 - 2.5 g/cc
DIN Flanges
Density Output Resolution: 0.0001 g/cc
Factory Pre-Calibrated Range: 0.5 to 1.1 g/cc Maximum W.P. 4 - psi (kPa)
Temperature Effect: Approximately < 0.000017g/cc/°C Model Sizes (mm)
Pressure Effect: Approximately 0.000042 g/cc/bar (Un- PN 40 PN 100
corrected) from calibration point (deviation from nor-
mal application pressure) S100 25
586 1200
Circulation Flow-Through: Max. 1,600 Kg/min (pulse (4040) (8274)
output) for S200. S200 50, 80, 100
Flow Indication Accuracy: Max. ±0.12%
Max. Operating Pressure: 82 Bar (8,274 kPa)
Max. Viscosity: 1000 mPa·s Sensor Enclosure
Sensor Temperature Range: -75°C to +200°C Flow sensor enclosure is seal-welded and back-filled with
All Material: Stainless steel HS 316L inert gas.
Flange Size: Variable Environmental Rating: NEMA 4X
Temperature: 100Ω - 4-wire RTD
Power Supply: 10-30 Vdc, 35mA typical, max. 75mA, Materials of Contruction
max. 1W
Signal Output: RS-232 Communication (Addressed) Flanges: 316L Stainless Steel
Three selectable digital outputs for: Other Wetted Parts: 316L Stainless Steel
• Mass flow Covers, Plugs: 300 Series Stainless Steel
• Volume flow Interconnect Wire Insulation: Teflon
• Quadrature of flow
• Density
• Temperature
• Pulse width modulation
• Status
Pressure Drop
S100
Data based on water - 1 cP and 1.0 specific gravity (1.0 g/cm3). For pressure drop on higher viscosity products, refer to
Bulletin AB0M007.
1 2 3 4 5 6 7 8 9 10 11 12 13
K M S J S A 1 J 0 0 A 2 4
Dimensions -
Inches (mm) Sensor
Sensor Flange ANSI
Weight -
Model Size Class
lb (kg)
A B
E 15.0 3.3 32
150
(381) (83) (14.5)
D
15.5 3.5 34
1" 300
(394) (90) (15.4)
B C 16.0 3.8 34
600
(406) (96) (15.4)
A
15.2 3.4 34
150
(387) (87) (15.4)
F 15.7 3.7 40
S100 1-1/2" 300
(400) (93) (18.1)
16.4 4.0 40
600
NPT (416) (101) (18.1)
15.4 3.5 38
150
(390) (88) (17.2)
15.7 3.7 40
2" 300
(400) (93) (18.1)
B B 16.6 4.1 42
A A 600
(422) (104) (19.1)
22.7 3.6 100
150
(578) (91) (45.4)
23.2 3.8 106
2" 300
(591) (98) (48.1)
24.0 4.2 112
Sensor Body 600
(610) (107) (50.8)
23.2 3.8 114
Dimensions - Inches (mm) Sensor 150
Sensor (591) (98) (51.7)
Weight S200 3"
Model 23.7 4.1 122
A B C D E F - lb (kg) 300
(603) (104) (55.3)
15.0 3.3 8.4 21.0 4.6 4.0 26 23.2 3.8 144
S100 150
(381) (83) (214) (533) (117) (102) (11.8) (591) (98) (65.3)
24.0 4.2 144
22.7 3.6 15.6 32.4 6.6 5.9 90 4" 300
S200 (610) (107) (65.3)
(577) (91) (395) (822) (168) (150) (40.8)
25.0 4.7 144
600
Note: S100 dimensions same with NPT connections. (635) (120) (65.3)
DIN Flanges
Dimensions -
DIN Inches (mm) Sensor
Sensor Flange
Nominal Weight -
Model Size
Rating lb (kg)
A B
15.5 3.50 32
PN 40
(394) (90) (14.5)
S100 DN 25
16.0 3.80 38
PN 100
(406) (96) (17.2)
23.2 3.80 104
DN 50 PN 40
(590) (97) (17.2)
23.8 4.10 120
S200 DN 80 PN 40
(604) (104) (54.4)
24.0 4.20 128
DN 100 PN 40
(610) (107) (58.1)
Headquarters:
1803 Gears Road, Houston, TX 77067 USA, Phone: 281/260-2190, Fax: 281/260-2191
Gas Measurement Products: Liquid Measurement Products:
Houston, TX USA Phone 281/260-2190 Erie, PA USA Phone 814/898-5000 Beijing, China Phone (86) 10/6500-2251
Thetford, England Phone (44) 1842-82-2900 Los Angeles, CA USA Phone 661/702-8660 Singapore Phone (65) 6861-3011
Kongsberg, Norway Phone (47) 32/286-700 Slough, England Phone (44) 1753-57-1515 Chennai, India Phone (91) 44/450-4400
Buenos Aires, Argentina Phone 54 (11) 4312-4736 Ellerbek, Germany Phone (49) 4101-3040
Integrated Measurement Systems: Barcelona, Spain Phone (34) 93/201-0989
Corpus Christi, TX USA Phone 361/289-3400 Moscow, Russia Phone (7) 495/564-8705
Kongsberg, Norway Phone (47) 32/286-700 Melbourne, Australia Phone (61) 3/9807-2818
San Juan, Puerto Rico Phone 787/274-3760
United Arab Emirates, Dubai Phone 971 +4/331-3646
Visit our website at www.fmctechnologies.com
Printed in U.S.A. © 4/99 FMC Technologies Measurement Solutions, Inc All rights reserved. SS0M021 Issue/Rev. 0.0 (4/99)