Sei sulla pagina 1di 10

A B C D E F G H I J KEY TO INSTRUMENTATION

Elation Proteus
5
Hybrid

0 0 Colorado 2 Solo 59

ETC 10deg 6
2003
Shelley
©Steve

ETC 14deg 8

ETC 19deg 10

1 1
ETC 26deg 2

GROUND ROW PROTECTION DETAILS


ETC 36deg 2
2003
Shelley
©Steve

ETC 50deg 3

ALTMAN 18"
10
SCOOP
2 2
LED TAPE RGBW 2

CuePix Batten 10

3 3
GENERAL NOTES
- Please have all color, templates, and accessories

ELATION CUEPIX BATTENS


framed and loaded prior to focus.

- Please have R119 and R132 in all sizes available at


focus call.

UNITS FOR GROUND ROW - All steel to steel truss/scaffold connections MUST be
coupled with cheeseboroughs.

ARE NOT WATERPROOF


PROTECT FROM WEATHER LEGEND
SUGGESTIONS SHOWN ABBREVIATIONS:
R = Rosco
FOCUS
COLOR
FOC
CLR
G = GAM
4 4 LENSº

PROPOSED WATERPROOFING
A = Apollo
LS = Line Set TEMPLATE
GP = Ground Plan G
LX = Electric UNIT # U#

1'-0
TD = Tech. Direct.
LD = Lighting Dsgnr

" CLEAR PLEXI


CHANNEL #

3'-7 1/4" DIMMER #

3/4" PLY

1'-0"

7"
5 SCAFF DECK 5
6 3/8"

http://www.mikewoodld.com
mike@mikewoodld.com

IMPORTANT:
813-716-1909 Cell / 646-694-8656 Studio
3161 Broadway #2C - New York, NY 10027
This drawing contains a visual concept and construction suggestions .
The lighting designer and design assistants/associates are not qualified
to determine or guarantee the structural integrity or appropriateness of

UNITS TO BE SCREWED
any construction or rigging methods , and assume no liability or
responsibility for the improper engineering , construction , or use of any
and all designs contained on this document and elsewhere throughout
the production . Always consult a licensed structural engineer before any
rigging or construction takes place . All applicable local and national fire
and life safety codes must be follwed at all times .

UNIT DIMENSIONAL DRAWINGS (1)


TO DECKING FOR SECURITY & NO.
REVISION HISTORY
REVISION DATE BY

ENTIRE GROUND ROW TARPED


A01 Document Prep 12 FEB 19 MW

TEN TOTAL UNITS


B01 SHOP PREP - REV 1 19 FEB 19 MW
>B02< ADDED CAFE LIGHTS 28 MAR 19 MW

6 EVERY NIGHT AFTER SHOW 6

MAMMA MIA
PRODUCTION STAFF
DIRECTOR . . . . . . . . . . . . . . . .STEPHANIE GULARTE

LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD


SCENIC DESIGNER . . . . . . . . . . . . . . . . . .JERID FOX
ASSOC. LIGHTING DESIGNER . .DALTON HAMILTON
ASST. LIGHTING DESIGNER . . . . . . . . . . . ABBY MAY
PROD. ELEC . . . . . . . . . . . . . . . . . . .CHRIS BALDWIN
- DEMEN'S LANDING PARK -
7 7 ST. PETERSBURG, FL 2019

DWG NUMBER
SCALE 1" = 1'

PG SIZE 36" x 24"


L18 OF 19

GROUND ROW
A B C D E F G H I J WEATHERPROOFING