INDUSTRIAL SERVICES, DEI.


MAGNETIC PARTICLE INSPECTION REPORT

SGS (Thailand ) Limited SGS Thailand Limited


100 Nanglinchee Road. Chongnonsee Yannawa Bangkok 206/6 Moo.1 Tambol Sathing Mo. Amphur Singha Korn Songkhla 90280
Contact No.: +66(0)2 678 1813 Contact No : +66(0)74 332 711
www.th.sgs.com www.sgs.co.th

Client: SOMAS Date of Inspection : 18-Nov-14


Address: SOMAS, SIDI LARBI Report No: 10
Project Name : WORKOVER SGS Ref No:
Contact Telephone : PO No:
Location : EL HANCHEN, ESSAOUIRA , MOROCCO Serial No: B109-4

Item Description:
3 1/2" Drillpipe Elevator Procedure/Acceptance Criteria

Areas Inspected: All stress baring Areas ✘ ASTM EN 709-1 ASME SEC V ART 7

Magnetic Ink Batch No: Babb v Co 09714/2 ASME SEC B31.3 BHEN-12079-1

✘ Light Intensity : >1000 LUX


White Background Batch No: Babb v Co 11614 @Test Surface
AWS D1.1

Testing
Equipment: System Surface Preparation
medium

Black Light Unit ✘ Black Magnetic Ink ✘ Wire Brush ✘ Wet

Permanent Magnet ✘ White background Blast Cleaning Dry

✘ AC Yoke
Fluorescent
Serial No. 17219 ✘ Power tools
Magnetic Ink

Lifting capacity AC Yoke : 10 lbs./4.5 Kgs. Pole spacing 5"

Sketch / Photo:

Coatings & Preparation: Wire and Power brush cleaning and paint remover

Visual Inspection Restrictions : None

Results of Examination: No visable indications found, Item was found to be fit for use.

Comments:

18-Nov-14
Date of Inspection:

Next of Inspection Date:


18/11/2015

TECHNICIAN: Reviewed By: John Dolan

Date : Date :

PF-TH-IND-IN-076/Ver.01/13.09.13/ Page 1 of 1