Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Perfectly sealable for careful Low profile variation for Permits use with automatic
storage of your samples up to 30% more space in systems ANSI/SLAS standard
your refrigerator
• Stackable and perfectly sealable with suitable sealing mats • Alphanumeric code and cut-away corner simplify sample
or self-adhesive sealing films. identification and orientation.
• According to ANSI/SLAS 1 and 4 for use with multichannel • Better visual inspection thanks to high-transparency
pipettes and automatic systems. polypropylene (PP) and clear polystyrene (PS).
6 1.2 ml
raised rim
of the wells
4 1.1 ml PS
5 1.2 ml
Low Profile
3 1.1 ml
7 2.2 ml
2 0.5 ml
96-well Deep-well Plates
Essential quality features of n Optimal sample mixing and recovery using smooth and chemi-
the deep-well plates made of cally inert well interior
PP are the use of high-qual- n Temperature range -80 °C to 121 °C
ity medical grade polypro-
n Plates of PP autoclavable at 121 °C (2 bar), acc. DIN EN 285
Better protection from contamination pylene and the high chemi-
with raised rim n Free from RNase, DNase, endotoxins and human DNA
cal resistance, e.g., against
DMSO, phenol and chloro-
Low Profile deep-well plate:
form. The ANSI/SLAS 1 and 4
n Reduced space requirements by about 30%
standards permit use with multi-
(height only 26.5 mm)
channel pipettes and automatic
liquid handling systems from all n 15% larger well cross-section (diameter 8.2 mm)
leading manufacturers.
Ordering Information
Plates
Description Capacity Material Well shape Well bottom Pack Cat. No.
ml of
* not autoclavable, usable down to -20 °C, ** not checked for absence of DNA, RNases, and DNases, no medical grade PP
8
Chemical-resistant, H2O-repellent,
7013 55 Silicone 50 7013 57
-80 °C to +120 °C
BRAND®, BRAND. For lab. For life.® and the word and figurative mark are registered trademarks of BRAND GMBH + CO KG,
Germany. Other reproduced brands are the property of the respective owner.
Our technical literature is intended to inform and advise our customers. However, the validity of general empirical values, and of
9940 47 · Printed in Germany · V0918 · WA/0918
results obtained under test conditions, for specific applications depends on many factors beyond our control. Please appreciate,
therefore, that no claims can be derived from our advice. The user is responsible for checking the appropriateness of the product
for any particular application.
California Residents: For more information concerning California Proposition 65, please refer to www.brand.de/calprop65
Subject to technical modification without notice. Errors excepted.