Sei sulla pagina 1di 2

Baker Hughes Incorporated

HPump
(918) 341-9600 200W Stuart Roosa Dr, Claremore, OK 74017

Project: System Inyection Pump: 34-862WIJ700A


Customer: Pacific Stratus ThChmbr: 875 HTC Inconel
Well: CrajoViejo Motor: Siemens WP-II 1250HP 4000V 157 A
Engineer: Jonathan Oyola Controller: VSD 8900-VT 1000kVA/ 480V/ 1283A
NOTE: Motor ratings at 60Hz

Comments:

34-862WIJ700A

HEAD (psi)

63 Hz

2500 60 Hz

55 Hz
2000

50 Hz

1500
45 Hz

40 Hz
1000

35 Hz

500

5000 10000 15000 20000 25000 30000 35000 40000 45000 50000
Flowrate (BPD)

AutographPC™ V9.0 File:Pacific Stratus Feb 2014.apcx


©Copyright 2016 Baker Hughes Inc. All Rights Reserved

Page 1 of 2
Baker Hughes Incorporated
HPump
(918) 341-9600 200W Stuart Roosa Dr, Claremore, OK 74017

Project: System Inyection Pump: 34-862WIJ700A


Customer: Pacific Stratus ThChmbr: 875 HTC Inconel
Well: CrajoViejo Motor: Siemens WP-II 1250HP 4000V 157 A
Engineer: Jonathan Oyola Controller: VSD 8900-VT 1000kVA/ 480V/ 1283A
NOTE: Motor ratings at 60Hz

Comments:

Operating Parameters / Selection:

Design Point:
Desired flow (total) 25000 BPD
Frequency 58.2 Hz
Boost Pressure 1750 psi

Pump Selection: Intake Discharge Pump Selected:


Pressure 50.0 psi 1800 psi IMW 34-862WIJ700A
Flowrate 25000 BPD 25000 BPD Pump eff = 80.24%
Specific Gravity 0.99 rel-H2O 0.99 rel-H2O Pshaft RPM = 3479
Viscosity 1.0Cp 1.0Cp Shft HP @ 58.2 Hz = 927.8
Shaft load =(Std 117%)
Required Motor HP at 60.0 Hz = 971.2

Thrust Chamber Selection:


Type 875 HTC Inconel Pressure Data:
No sand present Max Working Pressure 2470 psi
Pump uses fixed-type stages Max Allowable Working Pressure 1200 psi
Thrust Load 50.1 %
ShaftHPcap 2427 HP
Surface Motor Selection
Motor Selected =Siemens WP-II 1250HP 4000V 157 A
Terminal Voltage =3882.8 V
Motor Current =123.2 A
Load acc to N.P. =77.7 %
Max Elevation = 3300ft
Max Amb Temp =104.0ºF
Power Type =UNFILT
Frame =5810A

No comments

Controller Selection:
Surface KW 743.1kW Voltage Input 480.0V
Input kVA 823.5kVA Max Well Head Volts 3883V
System kW 792.6kW Target Frequency 58.2Hz (8.24V/Hz)
Max Ctrl Current 1014.7A Step-up Trafo 8.237 ratio
Power Cost/kWH 0.05$/kWH Selected: VSD 8900-VT 1000kVA/ 480V/ 1283A
No comments
Total Power Cost = $28533/month

AutographPC™ V9.0 File:Pacific Stratus Feb 2014.apcx


©Copyright 2016 Baker Hughes Inc. All Rights Reserved

Page 2 of 2

Potrebbero piacerti anche