No Question Option A Option B Option C Option D

1 Cross arms are made of Iron rod Angle iron Asbestos sheet Steel
2 Multicore cables are used upto 2000V 5000 V 11000 V 33000 V
3 A lead sheath in the To protect against the To protect the cable from To provide strength to To provide proper
underground cable is provided entry of moisture mechanical injury cable insulation
4 Open circuit fault in the cable is Induction test Murray loop test Capacity test Fall of potential test
found by
5 The function of conservator in a to prevent flow of to prevent flow of air into to improve the power to take care of expansion
transformer moisture into the tank the tank factor and contraction of oil

6 The chemical used in breather is sodium chloride silica gel copper sulphate silica sand

7 Buchholz relay is generally not 5 kVA 100 kVA 50 kVA 500 kVA
provided on transformers below
8 Main equipments required for High vacuum filtering Oil storage tank with Oil dielectric strength All of these above
filling the oil in transformers plant silica gel breather tester
9 Lightning arresters are located at the tower top at the generator terminal at the transformer at the line entry point of
terminal the power house
10 Control and relays panels are in open space in control room in the switch yard in close space
always located
11 The fault clearing time of a few minutes few seconds one second few cycles of supply
circuit breaker is usually voltage
12 The power factor of the arc in always zero always unity always lagging always leading
circuit breaker is
13 Main causes of electrical lack of earthing lack of proper protective not obeying instructions Working on live
accidents are device equipment
14 Painful electric shock is felt less than 1 ma from 1 to 8 ma from 8 to 15 ma from 15 to 50 ma
when magnitude of current
passing through human body is

15 The magnitude of fault current total impedence upto voltage at the fault point load current being both (a) and (b)
depends upon fault supplied before
occurance of fault
16 The Z per phase of a 3-ɸ 1.5 pu. 1.0 pu 0.5 pu 0.25 pu
transmission line on a base of
100 MVA 100 kV is 2 pu. The
value of this Z on a base of 400
MVA and 400 kV would be

17 Zero-sequence currents can grounded star/delta delta/star star/grounded star delta/delta


flow from a line to transformer
bank if the windings are in
18 Zero-sequence currents flow in double line to ground an overvoltage in the line a line to line faults. a fault across all the
a transmission line when there is fault caused by charged three lines.
loads.
19 The contact resistance of a 20 Ω 2Ω 20 m Ω 20 µ Ω
circuit breaker is about
20 The recovery voltage will be zero 0.5 0.707 unity
maximum forpower factor of
21 The pressure of SF6 gas in a 0.25kg/cm2 1 kg/cm2 4 kg/cm2 40 kg/cm2
circuit breaker is around
22 In a vacuum circuit breaker, the 1 torr 10-6 torr 10-12 torr 10-16 torr
vacuum is of the order of
23 A thermal protection switch overload temperature short-circuit over-voltage
provides protection against
24 Circuit breakers with reliability Air-blast SF6 oil Vacuum
and negligible maintenance is
25 The most suitable circuit breaker oil air-blast SF6 air-break
for short line fault without
switching resistor is
26 Making capacity of a circuit 2.55 times symmetrical 1.5 times symmetrical √2 times symmetrical symmetrical breaking
breaker is equal to breaking current. breaking current. breaking current. current.
27 Current ratingisnot necessary in isolators circuit breakers load break switches circuit breakers and load
case of break switches
28 Protective relays can be light intensity temperature resistance, reactance or all of the above
designed to respond to impedance.
29 Under voltage relays are mostly transformer protection busbar protection motor protection feeder protection
used for
30 A reactance relay is voltage restrained over- voltage restrained directional restrained directional restrained
current relay. directional relay. over-current relay. over-voltage relay.
31 Mho relays have an R-X plane a straight line passing a straight line parallel to a straight line parallel to a circle passing through
characteristic depicted by through origin. X-axis. R-axix. origin.
32 For phase fault the relay used is distance relay thermal relay over-current relay induction relay.

33 Where severe synchronising impedance relay mho relay reactance relay induction relay.
swing occurs, the relay
employed is
34 In three-phase system, what is three one six two
the minimum number of relays
used to detect phase-to-phase
faults
35 A static coincidence circuit is phase comparison amplitude comparison starting an impedance biasing a mho relay
used for relay
36 The percent bias for a generator 5 to 10 10to 15 15 to 20 20 to 25
protection lies between

37 Magnetising in-rush current in a 3rd harmonic component 5th harmonic component 2nd harmonic all odd harmonic
transformer in rich is component components
38 Bus-coupler is very essential in single bus-bar ring bus-bar double bus, double main and transfer bus
arrangement arrangement breaker arrangement
39 For complete protection of a 3- three phase and three three phase and two two phase and two earth two phase and one earth
phase transmission line we earth fault relays. earth fault relays. fault relays. fault relay.
require
40 Impulse ratios of insulators and both low. high and low low and high both high.
lightning arresters should be respectively. respectively.

41 In a thyrite lightning arrester the varies linearly with the increases with the decreases linearly with is high at low current and
resistance applied voltage. applied voltage. the applied voltage. low at high current.
42 A thyrite type lightning arrester blocks the surge voltage absorbs the surge offers a low resistance returns the surge back to
appearing in a line. voltage appearing in a path to the surge the source.
line. appearing in a line.
43 Steepness of the travelling line resistance. line inductance. line capacitance. both (b) and (c )
waves is attenuated by
44 The insulation level of a 400 kV lightning over-voltage switching over-voltage. corona inception voltage. radio and TV
EHV overhead transmission line interference.
is decided on the basis of

45 The advantage of neutral safety of personnel. reduction of earth fault elimination of arcing fault none ofhte above.
earthing is current. current.
46 Resistance earthing is employed 3.3 and 11 kV. 11 and 33 kV. 33 and 66 kV. 66 kV and 132 kV.
for voltages between
47 The method of neutral grounding positive-sequence negative-sequence zero-sequence network. both positive-and zero-
affects the network. network. sequence networks.
48 The voltage of a transmission excitation control. using induction regulator. reactive VAR injection any of the above
line can be controlled by methods.
49 Shunt compensation in an EHV improve stability. reduce fault level. improve the voltage substitute for
line is used to profile. synchronous phase
modifier.
50 For cost and safety the outdoor 11 kV and above. 33 kV and above. 66 kV and above. 110 kV and above.
substations are employed for
voltages
51 AC network analyser isemployed load flow. load flow and stability. load flow and short- load flow, stability and
for solving the problems of circuit. short-circuit.

52 The load carrying capability of a always limited by the limited by stability reduced at low ambient decreased by the use of
long ac transmission line is conductor size. considerations. temperatures. bundled conductors of
single conductors.
53 Steady-state stability of a power reducing fault clearing using double circuit line single pole switching. decreasing generator
system is improved by time. instead of single circuit inertia.
line.
54 The critical clearing time of a reactive power limit. short-circuit limit. steady-state stability transient stability limit.
fault in power system is realated limit.
to
55 The transient stability limit of a series inductance. shunt inductance. series capacitance. shunt capacitance.
power system can be
appreciably increased by
introducing
56 Load-flow study is carried out for load-frequency control. planning of power fault calculations. study of stability of the
system. system.
57 In load-flow analysis, the load constant current drawn constant impedance voltage and frequency constant real and
connected at a bus is from the bus. connected at the bus. dependent source at the reactive power drawn
represented as bus. from the bus.
58 In a load-flow study a PV bus is voltage limit is violated. active power limit is phase angle is high. reactive power limit is
treated as a PQ bus when violated. violated.
59 A 12-bus power system has 3 21 X 21 21 X 19 19 X 19 19 X 21
voltage controlled buses. The
dimensions of the Jacobian
matrix will be
60 Transmission efficiency voltage increases but voltage decreases but voltage and power factor voltage and power factor
increases as power factor decreases power factor increases both increase both decrease.
61 What type of insulators will be strain type shackle type Pin type. suspension type
used if the direction of the
transmission line is changed?
62 Feeders are used to link receiving end substation distribution transformer line in the consumer area generating station with
to distribution to consumer's area to the premises of the receiving end substation.
transformer consumer
63 The secondary distribution 3.0 kV, 3-phase, 3 wire 6.6 kV, 3-phase, 3 wire 1 kV, 3-phase, 3 wire 400/230 V, 3-phase, 4
system (A.C.) employs system system system wire system
64 In order to increase the limit of synchronous condensers series resistances are series capacitors and shunt capacitors and
distance of transmission line are used used shunt reactors are used. series reactors are used.

65 A power system load bus usually unity power factor leading power factor lagging power factor zero power factor
run with
66 To compensate Ferranti effect shunt capacitors are series capacitors are shunt inductors are used series inductors are used
used used
67 Connection of shunt capacitors increases regulation decreases regulation does not affect regulation maximise the regulation
at the receiving end bus of
power line
68 In a power system reactive for power transmission for stabilizing voltage for stabilizing frequency for counter acting the
power is necessary level effect of reactance in the
transmission system

69 In Fast Decoupled Load Flow singular zero square unity


method, the matrices [H] and [L]
are
70 The characteristic impedance of conductivity of the shape of the conductor surface treatment of the geometrical
a transmission line depends material conductors configuaration of the
upon conductors
71 A capacitor connected in parallel neutral displacement Ferranti effect loss of stability surges.
with an equipment provides
some degree of protection
against
72 Apart from the 'skin effect' the Faraday's effect Bundledconductor Proximity effect Ferranti effect
non-uniformity of the current
distribution is also caused by
73 If we increase the length of Decreases Increases Remains the same Not affected
transmission line, the charging
current
74 The method of images originally Calculationof inductance Calculation of resistance Effect of earth on line None of the above
suggested by Lord Kelvin is capacitance
used in
75 The capacitance becomes short transmission lines. medium transmission Both (a) and (b) Long transmission lines
increasingly important for lines.
76 A long line under no load Shunt resistance at Shunt reactors at the Shunt capacitors at all of the above
conditions, for a good voltage receiving-end receiving-end receiving-end
profile needs
77 With 100% series compensation Low transient voltage High transient current The current is series both (b) and (c )
of lines resonant at power
frequency
78 In Gauss-Seidel method of Gauss constant Acceleration constant Blocking factor Deceleration constant
power flow problem, the number
of iterations may be reduced if
the correction in voltage at each
bus is multiplied by

79 For accurate load flow Newton Raphson Gauss Seidel method Decoupled method Fast Decoupled Load
calculations on large power method Flow
systems, the best method is
80 Which one of the following is not Corona loss is more than Back-to-back connection Distance limitation exists Extra reactor power has
true for HVDC transmission? a HVAC is possible to be supplied

81 The Parliament of India consists Rajya Sabha and Lok Rajya Sabha, Lok Sabha Rajya Sabha, Lok Sabha Rajya Sabha, Lok Sabha
of Sabha only and the Prime Minister and the President and the Chief Justice of
India
82 Which of the following is an Deuterium Nitrogen Calcium Magnesium
element of Heavy Water?
83 Which bird is considered to be Black Eagle Swift Peregrine Falcon Silver Hawk
the fastest in the world?
84 Which part of the human body is skin lungs eyes bone marrow
most vulnerable to nuclear
radiation?
85 Find the correct Combination DC motor - Nikolo Telsa Laptop - Sinclair Computer - Digital Corp. CD - Sony

86 Name India's first electric car Reva RAV4 Pirus RAV 6


manufactured by Maini Group
87 Which sportsman promoted the Geet Sethi Sunil Gavaskar Anil Kumble Mahesh Bhupathi
portal kheladi.com, which was
eventually acquired by Sify?

88 An android is any robot that Has more than one basic Has the ability to make Is built by other robots Looks and acts like a
function decisions and formulate human
plans
89 When is Martyr's Day celebrated 2nd October 30th January 22nd March 24th January
90 Who is the first and fastest Parmjeet Singh Mihir Sen Narayan Karthikeyan Saloo - Neha Choudhari
indian to circumnavigate the
earth by car?
91 <b>Choose the meaning of the Behaves dishonestly. Works for both sides. Creates discord among Argues in support of both
idiom or phrase :-</b> Cut both friends sides
ends
92 <b>Choose the meaning of the Ridiculed him Suspended him Reprimanded him Grinned him
idiom or phrase :-</b> Took him
to task
93 <b>Choose the meaning of the Resigned Got fired of Was demoted by Was dismissed from
idiom or phrase :-</b> Got the
sack from
94 <b>Find part of sentence with Since I meet Dinesh last Saturday he has been contacting everday over phone
grammatical or idiomatic error in me
it :- </b> Since I meet Dinesh
last Saturday he has been
contacting me everday over
phone
95 <b>Find part of sentence with Had you informed me I would have certainly purchase the car from you
grammatical or idiomatic error in earlier
it :- </b> Had you informed me
earlier I would have certainly
purchase the car from you

96 <b>Find part of sentence with We have carefully considered the importance of issues in the report
grammatical or idiomatic error in raised
it :- </b> We have carfully
considered the importance of
issues raised in the report
97 <b>Find part of sentence with Due to his health Mani retired from the service last year
grammatical or idiomatic error in problem
it :- </b> Due to his health
problem Mani retired from the
service last year
98 The Judge used legal discretionary special absolute
his________________power
and let him off with reprimand.
99 Man is exaggerated astonished instrumental accountable
sometimes______________in
destroying something that is
most precious to him
100 It is time that both modernists essentially indispensability justification implications
and traditionalists reconsidered
the ______________ of
secularism in political life.

Potrebbero piacerti anche