Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Specifications, designs and other content appearing in this brochure are current as of December 2015 but subject to change without notice.

c All rights reserved 12/15 SS


P.3

This new series has been designed to meet ISO criteria for CSPF*. Compared with non-inverter models,
annual power consumption is about 50% less. Not only is power consumption reduced during low-load
periods, but cooling capacity is better during peak load periods.
*CSPF, cooling seasonal performance factor

P.4

Comes with highly efficient heat exchanger and, through optimized design of the system circuit,
the outdoor unit is even more compact!

P.5 P.7

As well as the comfort provided by inverter control, With automatic safeguards to protect against low
the ‘Quick cooling start’ function more quickly voltage, the system is tough enough to withstand
lowers room temperature and dehumidifies the air. supply voltage fluctuations.

P.8 P.9

Advanced Daikin inverter technology brings various Reuse of existing piping makes it easy to upgrade
benefits to owners. indoor and outdoor units.

P.10 P.11

-Possible to force On–Off using external command. Smart airflow enables flexible installation to room
-Ability to connect to high level control system without conditions without affecting comfort.
optional adaptor.
5.0–7.1 kW class 10.0–14.0 kW class

1 2
Throughout the cooling season, New outdoor units save even more space NEW
Daikin’s new inverter models reduce energy consumption NEW
92kg 73kg
Compared with previous non-inverter series, the new RZR-M series uses about 50% less power More
consumption. Get quick and effective cooling, and cut electricity bills. compact,
Comparison of cooling seasonal power consumption much higher
based on average CSPF values
1,345 CSPF!
990
mm

100
23%
mm

50%
reduction
power consumption
Cooling seasonal

in volume
320
900 320 940 mm
mm mm
mm

50 reduction! R48NUY1 RZR140MYM


(In case of 14.0kW class)

Compared to the previous mainstream non-inverter series,


outdoor units are much more compact.
Previous New inverter
Easy installation in places with limited space.
non-inverter series RZR-M series
(average) (average)
(cassette type) (cassette type) class 7.1/7.6 kW 10.0 kW 12.5 kW 14.0 kW
Note: Value 100 represents the amount of electricity used by a non-inverter model during a similar annual cooling period. R26NUV1 R36NUY1 R42NUY1 R48NUY1

70kg 79kg 87kg 92kg

CSPF values by capacity for cassette models Previous


CSPF 7
non-inverter
1,170 1,170 1,345
Value series 770 mm mm mm

6 6.47 mm

6.19
5.99
5
5.13 5.00 New inverter RZR-M series 900mm
4.85 900mm 900mm 900mm
4
R410A (cassette type)
Previous non-inverter series
3 R22 (cassette type)
2.77 2.69 2.79 2.79 2.73
2.63
2 * CSPF (cooling seasonal performance factor) is a RZR100MVM RZR125MVM RZR140MVM
new international energy-efficiency criterion RZR71MVM
MYM MYM MYM
calculated by methods stipulated in ISO 16358-1.
1 New 43kg 65kg (VM)
73kg (YM)
0 What is CSPF? inverter
CSPF is the value for the annual total
Inverter RZR50 RZR60 RZR71 RZR100
MVM
RZR125
MVM
RZR140
MVM cooling load divided by the annual total RZR-M 595
990
mm
MVM MVM MVM
MYM MYM MYM mm

Non R18 R21 R26 R36 R42 R48


power consumption at outdoor air series
condition specified by ISO standard.
Inverter NUV1 NUV1 NUV1 NUY1 NUY1 NUY1
845mm 940mm

3 4
Benefits of Inverter

Why is inverter technology economical?

unit price + cost of electricity


Inverter system consumes
less electricity, and soon Non inverter Inverter

Total cost =
recovers the difference in
initial cost. This results in
Inverters save more
lower total cost. energy over time
Faster cooling and dehumidification:
New inverter control technology brings quick comfort NEW Recovery point
Time

Quick cooling start function Inverter air conditioner can adjust its cooling
Inverters operate without repeated
Quickly and easily make space comfortable before the arrival of office capacity according to the cooling load.
On/Off operation.
workers or shop customers. As well as quick cooling at max. capacity, This results in less power consumption.
new inverter control rapidly removes indoor humidity. More than simple Rated condition Inverter Highway driving
temperature reduction, this twin reduction provides greater comfort BRC1E62 wired remote controller
(within 30 minutes max.). is used for ‘Quick cooling start’.
New Inverter (RZR-M series) Non inverter cooling capacity

Capacity ratio
Usual Inverter (RZR-L series)

Load ratio
1.0 On/Off operation
Non inverter
Worse efficiency Inverter cooling capacity
Capacity Continuous driving without stopping and starting is
more fuel efficient.
Cooling load Partial load area
INV Max
0 Non inverter City driving
Non Max 35
Outdoor ambient temperature (°C)
Stop, go, stop ...
Better performance
In response to fluctuating cooling load , non-inverter air conditioners
than non-inverter models!
repeatedly perform On (full-power)/Off (zero-power) operation. Inverter
Reaches max. capacity faster
than usual inverter models. air conditioners, however, operate at optimal cooling capacity according
to the cooling load. Since inverter air conditioners provide required
minimum cooling capacity with minimum electrical power, total power Constantly stopping and starting consumes energy
Start Time and is less fuel efficient.
consumption can be reduced during cooling period.

Indoor Reaches the


temp. setting temperature Why is inverter technology more comfortable?
faster.

Start When temperature does not fluctuate much, the set Inverter
temperature is maintained.
Inverter control responds to load changes and causes minor temperature
adjustments. Non-inverter control frequently turns ON and OFF in response to load
Setting fluctuations or load mismatch and causes large temperature swings.
temp.
Start Time Non inverter

Room Too hot


Indoor Removes temperature
humidity humidity faster. Large
temperature
fluctuation

Start Set
temperature
Non inverter Comfortable
Small
temperature
fluctuation
Inverter
Non inverter
Too cold Too cold

Start Time Time

5 6
C onvenient
And more... Advanced Daikin inverter technology
brings various benefits to owners and installers.

Automatic protection Coated printed circuit boards Navigation remote controller BRC1E62 includes various convenient functions
against low voltage
Coated circuit boards prevent Automatic return to temperature preset by owner. Owner can preset upper and lower temperatures.
problems caused by humidity Setpoint auto reset Setpoint range set
In AM and PM peak electricity consumption periods,
and airborne dust. - Even if the set temperature is - Saves energy by limiting the min.
supply may fluctuate. Built-in low-voltage protection changed, after a preset period and max. set temperature.
will automatically cut operations. When normal voltage new set temperature returns to - Avoids excessive heating or cooling.
preset value. - This function is convenient if the
is restored, operation will resume as before. - Period selectable from 30, 60, 90, remote controller is installed where

Self-diagnosis functions enable or 120 minutes. anyone can change the settings.

Outdoor unit installation is possible prompt maintenance response


even with limited space
Restaurant opened Full tables at lunchtime After 30 minutes*

An error message appears on the LCD of the Restaurant 27 °C 24 °C Returns to


remote controller and an LED lights up on the unit. example 27 °C
automatically
When the BRC1E62 is installed, the error code
appears showing contact information and model
name. Contact your Daikin dealer and
provide the error code and model name. Temperature is set to 27ºC Then is lowered to 24ºC Automatically returns to
for crowded room preset temperature (27ºC)
100
m or *Preset-return time can be set
mo m or m me at 30, 60, 90, or 120 min
re 0 r
100 10 mo re
m
mo m or mo
or
re
50
0m
m Demand Control Function
* RZR100-140 only.
* Field setting
By setting limits that restrict power consumption, * Required for KRP58M51 (Option)
Limitation
you can cut electricity bills.

consumption
Power
Power consumption is given first priority, and limits maximum power
consumption of unit.
Maximum power consumption can be set at 40, 60, 70, 80, or
100%. 8:00 12:00 16:00 20:00 Time

*Please refer to Service Manual.

High sensible cooling enables High dehumidification cooling Night quiet operation mode
even greater power savings provides even greater comfort Consideration for people living nearby Peak outdoor temperature
*Field setting with remote controller

Capacity (%)
Outdoor unit operating
In locations such In restaurants 100
sound can be reduced. The operating
as simple server and other spaces
rooms, where many noise bothers 8 hours
me at night! 50 10 hours
dehumidification is people gather,
not required and ‘High dehumidi-

Load (%)
greater power fication cooling’ 0
savings are mode reduces 48

Sound (dB(A))
Rated
possible with 'High humidity and

Operating
sensible cooling' creates greater Quiet mode
44 Quiet mode
mode. comfort.
8:00 12:00 16:00 20:00 0:00 4:00 8:00

Note: Daikin data for RZR71MVM


*Field setting with remote controller. *Available with RZR100–140M models. Field setting on outdoor unit. Operating sound about 4 dB quieter

7 8
Reuse of Design
existing piping flexibility
(RZR-M series only.)

Benefit 1 Simplified installation reduces replacement time and cost Possible to force On–Off operation using external command
(Available in duct connection middle static pressure type and wall mounted type)
*Field setting with remote controller
When considering air conditioner These
problems solved by Daikin! Off-operation never overlooked if linked to use of hotel keycard: enables overall power savings.
replacement, do the following are
things concern you? Where feasible,
Duct connection Wall mounted type
middle static pressure type FAQ-C series
For how long will the business by reusing existing pipes*, FBQ-E series
have to close down?
While replacement work is going on,
we cut your work cost and Lighting

how will sales be affected? reduce work time. Interlock


Won’t the costs be high and work period longer because *Strict conditions apply, please check the table on page 52
scaffolding is necessary for pipe replacement? for acceptable pipe sizing (if pipes are to be reused).

Interlock
Benefit 2 You can increase cooling capacity and achieve higher energy efficiency

Upgrade to an air conditioner with the latest technology for greater comfort and energy efficiency.
*Other type of indoor unit is available by using optional adapter.

R22 R410A
Non inverter inverter
7.6 kW
class
14.0 kW
class
All indoor units comply with D -Net standards (connected to RZR series units)
φ9.5 φ15.9 φ9.5 φ15.9
Pipes used Previous indoor unit New indoor unit
as they are!

FHC26NUV1 FCQ140KAVEA As a result, the greater capacity units


R26NUV1 RZR140MVM ensure better performance to cope with
Adaptor not
required
the increasing amount of heat generated
by office equipment and occupants. Optional
FHQ-BV interface adaptor
is required FHQ-DA

Technology
VRV
VRV
Advanced technology including the use of corrosion resistant electronic expansion valves, acid neutralisers and improved compressor
reliability enables the re-use of existing piping* without the need of pipe flushing for a simplified replacement process.

Stronger refrigerating Highly corrosion resistant Highly reliable


machine oil electronic expansion valve compressor
An acid neutraliser agent is added to disable Compressor durability is improved
acids (chlorine ions), which cause corrosion. by installing a filter or accumulator
to collect solid foreign substances.

Acid neutraliser
Filter or
accumulator
Acid (chlorine ion)
Compressor

Refrigerant pipe

*Strict conditions apply, please check the table on page 52 for acceptable pipe sizing (if pipes are to be reused). Thanks to easy connection to DIII-NET and long piping length, suitable for projects that include VRV and SkyAir.

9 10
Smart
airflow control

All indoor units can provide 3-step fine control of air volume Airflow pattern is selectable to match room shape and installation location
(connected to RZR series units)

Typical flow patterns There are a total of 23 flow patterns. See page 18-19
Cassette type
Comfort ensured by ‘Auto’ airflow rate that matches load level <Round Flow>
L-shaped 2-way flow Opposite 2-way flow
You can freely set air discharge
(Available in wall mounted type, duct connection middle static pressure type, and floor standing type) setting by remote controller.

(1) Standard setting


Convenient energy-efficiency for stores
with peak and quiet periods.
(E.g., installed in (E.g., installed in
a corner) a long room)

All-round flow 3-way flow


(2) Ceiling soiling prevention setting

Low Medium High Auto

(E.g., installed in (E.g., installed


middle of ceiling) near a wall)
4-way flow also possible.

See page 24
Ceiling suspended type Long or wide airflow

Also convenient for high ceilings and spaces with long blow distances
Cassette type <Round Flow>: Ceiling suspended type: *Field setting with remote controller
max. 4.2 m max. 4.3 m

4.2 4.3
m m

See page 32
Floor standing type Choose one of three directions

See page 19 See page 24


Pattern 1 Pattern 2 Pattern 3
Swing wide across the front Swing across left side Swing across right side

11 12
Product Lineup
Series 25 35 50 60 71 100 125 140 125 140
NEW NEW NEW NEW NEW NEW NEW NEW
CEILING MOUNTED
CASSETTE TYPE
Round Flow Page 17
Indoor unit FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ125KAVEA FCQ140KAVEA
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR100MYM RZR125MVM RZR125MYM RZR140MVM RZR140MYM RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

COMPACT MULTI FLOW


CEILING MOUNTED
CASSETTE TYPE Page 21
Indoor unit FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Outdoor unit RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG

CEILING SUSPENDED TYPE NEW NEW NEW NEW NEW NEW NEW NEW

Page 23
Indoor unit FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA FHQ125DAVMA FHQ140DAVMA
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR100MYM RZR125MVM RZR125MYM RZR140MVM RZR140MYM RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1
WALL MOUNTED TYPE

Page 25
Pair

Indoor unit FAQ100CVEA


Outdoor unit RZR100MVM RZR100MYM

CEILING MOUNTED
BUILT-IN TYPE
Page 27
Indoor unit FBQ50BV1A FBQ60BV1A FBQ71BV1A
Outdoor unit RXS50FAVMA RXS60FVMA RXS71FVMA

DUCT CONNECTION NEW NEW NEW NEW NEW NEW NEW NEW

MIDDLE STATIC
PRESSURE TYPE Page 29
Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE FBQ125EVE FBQ140EVE
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR100MYM RZR125MVM RZR125MYM RZR140MVM RZR140MYM RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

FLOOR STANDING TYPE

Page 31
Indoor unit FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FBQ140CVEB FVQ125CVEB FBQ140CVEB
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR100MYM RZR125MVM RZR125MYM RZR140MVM RZR140MYM RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

CEILING MOUNTED NEW NEW

CASSETTE TYPE
Round Flow Page 38
Indoor unit FCQ60KAVEAx2 FCQ71KAVEAx2
Outdoor unit RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

CEILING SUSPENDED TYPE NEW NEW


Simultaneous Twin Multi

Page 38
Indoor unit FHQ60DAVMAx2 FHQ71DAVMAx2
Outdoor unit RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

DUCT CONNECTION NEW NEW

MIDDLE STATIC
PRESSURE TYPE Page 38
Indoor unit FBQ60EVEx2 FBQ71EVEx2
Outdoor unit RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

FLOOR STANDING TYPE

Page 38
Indoor unit FVQ60CVEx2 FVQ71CVEBx2
Outdoor unit RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

NEW NEW NEW NEW NEW NEW NEW NEW NEW


OUTDOOR UNIT

Page 33

Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR100MYM RZR125MVM RZR125MYM RZR140MVM RZR140MYM

Outdoor unit RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1

OUTDOOR UNIT

13 Outdoor unit RKS25AVMG RKS35AVMG RKS50AVMG / RXS50FAVMA RKS60AVMG / RXS60FVMA RXS71FVMA 14


Daikin meets your needs with this full line up of inverters for various types
of indoor units and power supplies
CEILING MOUNTED CASSETTE TYPE Round Flow DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

CEILING SUSPENDED TYPE FLOOR STANDING TYPE

COMPACT MULTI FLOW CEILING CEILING MOUNTED


WALL MOUNTED TYPE
MOUNTED CASSETTE TYPE BUILT-IN TYPE

15 16
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette air conditioner with 360° Avoids uneven temperature and discomfort caused by drafts

Comfort enhanced by Round Flow!


uniform airflow sets the standard 360° airflow Air movement is gentle
NEW With uniform temperature with Round Flow
FCQ50/60/71/100/125/140KA distribution Enhanced Comfort
360° airflow can
maintain comfort
Airflow even if air
distribution discharge speed is
creates uniform lower.
comfort throughout
the space.
Velocity decreases by
25% when set
Room remains temperature is raised
comfortable even 1℃ to 1.5℃.
when set
Greater comfort temperature is
raised 1℃.

Option
Accessory required for indoor unit. Adapts easily to the installation space
Navigation Remote Controller Because air flows out from corner outlets, comfort spreads more widely
(Wired Remote Controller)
Typical flow patterns There are a total of 23 flow patterns.

BRC1E62 All-round flow 3-way flow


L-shaped Opposite
2-way flow 2-way flow
Note: Remote controller cable is not
included and must be procured
locally.

Wired LCD remote controller (E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in
middle of ceiling) near a wall) a corner) a long room)
BRC1C61 4-way flow also possible.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
Note: Remote controller cable is not
close each unused outlet.
included and must be procured
locally. Operation sound increases when using 2-way or 3-way flow.

Grime prevention and antibacterial coating: Make cleaning easier


Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
External panels are treated with a coating that
BRC7F635F repels dirt Treated
surface
Untreated
surface
To prevent dirt sticking to the
Signal receiver unit
(Installed type) external panels, they have Resists
soiling
Wireless remote controller is supplied in a
been coated with a surface Grimy
• Condition after exposure
to the smoke of 600
set with a signal receiver.
treatment surface cigarettes in 1 m3
enclosed space.

Silver ion anti-bacterial Non-flocking flaps Filter has anti-mould and


drain pan antibacterial treatment
A built-in antibacterial treatment that uses Condensation does not easily form on Prevents mould and microorganisms
silver ion in the drain pan prevents and dirt does not cling to non-flocking growing out of the dust and moisture
the growth of slime, bacteria, and mould flaps. that adheres to the filters.
that cause smells and clogging. It is easy to clean.
17 18
CEILING MOUNTED CASSETTE TYPE Round Flow

Unified square panels Compact body and quiet operation dB(A)


Easier to maintain
Panel size is the same for all models, FCQ50-140KA. Sound pressure level
It is easy to maintain a neat appearance when multiple Indoor unit
High Middle Low
The condition of the drain pan and the
open
units are installed in the same room.
50KA 35 31.5 28 drain water can be checked by Just on grille
!
c t i
mm 95 60KA 35 31.5 28 removing the drain plug and su
950 0m
Same for 71KA 35 31.5 28 Drain plug
m suction grille
all models 100KA 43 37.5 32
125KA 44 39 34
140KA 44 40 36 With Ultra long-life filters (option), maintenance is not required in normal shops or offices
for up to four years
Optimal comfort and convenience Quick and easy to install
assured by 2 air discharge modes Just 256 mm high. Installable in tight
ceiling spaces (50–71KA)
Options required for specific operating environments

Air direction Standard setting1


Setting to prevent soiling Ultra long-life filter unit Sealing material of air discharge outlet
of ceiling2 (field setting) Even in dusty environments where the air Sealing material block air discharge openings not used in 2-way or
Recommended for shops with 256 mm *1 266 mm *2 conditioning is on most of the time, the ultra long-life 3-way blow.
Desired Standard setting to
light coloured ceilings that
situation prevent draft. filter only has to be cleaned once a year.
must be kept spotless.
Filter chamber
Branch duct (direct-connection round duct)
*1 298 mm high with 100–140KA (Can be used with high-efficiency filter)
A round duct can be attached without the need for a chamber.
Auto-swing Auto-swing between Auto-swing between
*2 308 mm high with 100–140KA A flanged port for direct connection of a round duct is provided. An
15° and 60° 25° and 60° existing branch duct chamber can also be fitted (square slit hole).

5-levels Easy height adjustment Ultra long-life filter Fresh air intake kit Note 1.2 Outside
air direction Settable to 5 different Settable to 5 different Each corner of the
setting Dusty area: annual filter change
Using this kit, a duct can be
levels between 15° and 60° levels between 25° and 60° unit has an Adjuster connected to take outdoor air
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.)
Pocket that lets you 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year in.There are two chamber types that
Auto air The air direction is set automatically to the easily adjust the have intake in two places: with
direction control memorised position of the previous air direction. unit's suspended Ordinary store or office: filter change every 4 years
*For dust concentration of 0.15 mg/m3 T-duct joint and without T-duct joint.
height. 4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years
Note: x 4 years The units can be installed in the following different ways.
1
Air direction is set to the standard position when the unit is shipped from the factory. Note:
The position can be changed from the remote controller. If the wireless remote Chamber type (without T-duct joint) Note 3.4
Closing of the corner discharge outlets is recommended.
High-efficiency filter unit
2
controller is installed, a signal
KDDP55B160
receiver unit is housed in one
of the adjuster pockets. Available in two types: 65% and 90% colorimetry. Flexible duct
(procured locally)
Suitable for high ceilings Filter chamber
(Can be used with ultra long-life filter)
T-duct joint
Even in spaces with Standard Setting Setting All models can be installed without Suction
(procured locally)

high ceilings, a Intake duct

comfortable airflow
using lifter because of the light weight chamber
(procured locally)
(duct length: 4 m max.)
Connection
is carried down to High-efficiency filter chamber
the floor level. 4.2 Installed in any direction
3.2 3.6 Chamber type (with T-duct joint) Note 3.4
m m Since the orientation of
m the suction grille can Insulation kit for high humidity KDDP55B160K
be adjusted after Please use if you think the temperature and humidity Flexible duct
installing, the direction inside the ceiling exceeds 30°C and RH 80%,
When all round flow is selected, ceilings up to 4.2 m in height can be of the suction grille respectively. T-duct joint
accommodated. (100-140KA) lines can be unified
Suction
when multiple units Top panel insulation(1) chamber Intake duct
(procured locally)
are installed. Top panel insulation(2) Connection (duct length: 4 m max.)
chamber
Top panel insulation(3)
Criteria for ceiling height and number of air discharge outlets
Insulation for decoration panel Direct installation type
(Ceiling height is reference value) Drain pump is Side panel insulation
KDDP55X160
Number of air discharge outlets used
equipped as Suspension bracket insulation
50–71KA 100–140KA
All round 4-way 3-way 2-way All round 4-way 3-way 2-way standard 850 mm

Standard
flow flow flow flow flow flow flow
2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m
flow
accessory with 175 mm Panel spacer
Ceiling
height
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m 850 mm lift Use when only minimal space is available between Duct flange
(with insulation material)
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m - drop ceilings and ceiling slabs. Intake duct
Note: Factory settings are for standard ceiling height and all-round flow. (procured locally)
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Transparent drain socket Note: 1 Use of options will increase operating sound.
2 Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts
Two selectable temperature-sensors See page 41 40mm should, as required, be procured locally.

DIII-NET communication standard Panel spacer 3 When a local-procured fan is used, an interlock with air conditioner is
necessary.Optional PCB(KRP1C63)is required for interlocking.
Connection to a centralised control system Note: Some ceiling constructions may hinder installation.
4 It is recommended that the volume of outdoor air introduced through the kit is
limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher
is available without option.
Switchable fan speed: High/Middle/Low Contact your Daikin Dealer before installing your unit.
quantities will increase the operating sound and may also influence temperature

Control of airflow rate has been improved from 2-step to 3-step. Low gas pressure detection See page 42
sending.

19 20
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE

Quiet decor-blending form and easy Compact Comfortable


installation in new or old buildings
Sized to fit inside 600mm wide Designed for low draft
ceiling grids performance
0 Horizontal flow 0

575 mm
FFQ25/35/50/60B 575 mm
Less draft
can be felt
286 tion
mm Decolrais also
e
pan act.
comp
Consistent comfort throughout
700 mm Auto-swing operation Airfow direction can be
distributes conditioned air adjusted in accordance with
more evenly. room conditions.
700 mm Auto-swing 5-levels air direction setting
Fits without the need to cut T-bar grid Standard 0
0
setting Auto-swing Settable to 5 different levels
Ceiling panel 60
between 0 and 60 60
between 0 and 60

T bar Draft
prevention 0 0
setting Auto-swing Settable to 5 different levels
(Set on site) 35 between 0 and 35 35 between 0 and 35

600 mm Setting to
600 mm prevent
soiling of 25 Auto-swing 25 Settable to 5 different levels
ceiling
Option (Set on site) 60
between 25 and 60
60
between 25 and 60

Accessory required for indoor unit. The control box is built in to the
Note: This angle above is provided as a guide.
unit, so maintenance is possible
Navigation Remote Controller by simply removing the grille.
(Wired Remote Controller) An inspection opening is not Multi-Flow System Air direction can be
required even for modules other
than 600 x 600. 4-way flow selected according to
BRC1E62 installation
1 pattern
Note: Remote controller cable is not
included and must be procured
locally. 3-way flow

4 patterns

Wired LCD remote controller Quiet


Quiet, but small-diameter fan 2-way flow
BRC1C61
Quiet operation is achieved even with a 1 pattern
Note: Remote controller cable is not compact body and developed spiral hub cover that
included and must be procured
locally.
reduces the static pressure inside the indoor unit. " " denotes piping direction. Drain piping
" " denotes sealing member for air discharge
outlet (option) . Note: Operation sound increases
when using 2-way or 3-way flow.
Note: For 3-way or 2-way flow installation, the sealing
member for air discharge outlet (option) must
be used to close off the unused outlet(s).

Wireless LCD remote controller


A signal receiver must be added to the indoor unit. Two selectable temperature-sensors
Both indoor unit and wired remote controllers contain temperature- sensors.
BRC7E531W
Temperature sensing can be set at the unit or, to further improve comfort level,
closer to the target area at the wired remote control. This feature require initial
Signal receiver unit
(Installed type) setting by the installer.
Wireless remote
controller is supplied
Spiral hub cover *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
in a set with a signal
receiver.
dB(A)

Sound pressure level Switchable fan speed: High/Low


Indoor unit
High Low High setting provides maximum reach while low setting minimizes drafts.
25B 29.5 24.5
35B 32 25 Drain pump is equipped
50B 36 27 as standard accessory 750 mm
60B 41 32 with 750 mm lift

21 22
CEILING SUSPENDED TYPE

Comfortable airflow travels The latest stylish


model
Installation flexibility for
freedom of design
throughout the room Sophisticated
design
Flexible installation
The unit fits more snugly 30 mm 30 mm
Flap neatly closes into tight spaces. or more or more

NEW when not in use. *Water used in the test-run can be drained from the air
discharge opening rather than from the side as was
FHQ50/60/71/100/125/140DA White colour
formerly the case.

Drain pump kit (option) can 600


mm
be easily incorporated

Comfortable Drain pipe connection can be done


inside the unit. Refrigerant and drain
pipe outlets are at the same opening.
Drain pump kit
(built inside
the unit)
The technology of the DC fan motor, wide
sirocco fan, and large heat exchanger DIII-NET communication standard
combine for greater airflow and quiet Connection to a centralised control system is available without
operation option.

All wiring and internal servicing can be done


Option Auto swing (up and down) and louvers from under the unit
Accessory required for indoor unit.
(left and right by hand) bring comfort to Easier piping work for
Navigation Remote Controller the room rear side by removable
(Wired Remote Controller)
frame
BRC1E62 Louver manually adjusts for straight or
Note: Remote controller cable is not
included and must be procured
locally.
wide angle airflow
Easy maintenance
Drain pump kit (option) includes a silver ion
antibacterial agent that assists in preventing
Wired LCD remote controller the growth of slime, bacteria, and mould that
cause smells and clogging
BRC1C61
Note: Remote controller cable is not
included and must be procured Non-flocking flap
locally.
Suitable for high ceilings Condensation does not easily form on and
dirt does not cling to non-flocking flap.
It is easy to clean. Non-flocking flap

4.3
Wireless LCD remote controller 3.5 m
A signal receiver must be added to the indoor unit. m Easy-clean, flat surfaces
It is easy to wipe dirt off the flat side and lower surfaces of the unit.
BRC7GA56
50-71DA 100-140DA

50-71DA 100DA 125/140DA Quiet operation dB(A)


Standard 2.7m or less 3.8m or less 4.3m or less
High ceiling 2.7m~3.5m 3.8m~4.3m - Sound pressure level
Signal receiver unit (Installed type) Indoor unit
Wireless remote controller is supplied in
High Middle Low
Note: Factory settings is “standard”.
a set with a signal receiver.
“High ceiling” are set with remote controller by field setting. 50/60DA 37 35 32
71DA 38 36 34
100DA 42 38 34
125DA 44 41 37
Two selectable temperature-sensors 140DA 46 42 38
See page 41

Switchable fan speed: High/Middle/Low


Oil resistant grille
Oil-resistant plastic is used for the air suction grille. This satisfies
durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification
Programme "Dry" See page 41 is not suitable for kitchens or other harsh environments.

23 24
WALL MOUNTED TYPE

Compact design and Compact & Design and


easy installation Sophisticated design
FAQ100
9kg lighter FAQ100BV FAQ100C
installation flexibility
6-direction
refrigerant piping
Left pipe

FAQ100C Height 360mm 340mm offers greater


340
mm Width 1,570mm 1,200mm installation Back-left pipe
Depth 200mm 240mm flexibility Bottom-left pipe
1,200mm
Back-right pipe
Right pipe
370mm shorter Weight 26kg 17kg Bottom-right pipe

Maintenance possible from the front


Flaps neatly close when not
of the unit
in use All maintenance tasks can be carried out via front
access. During servicing, attachment and detachment
of parts is easier.
Fresh white colour
Drain pump kit is available as option
Installs onto side of unit.

Comfortable
Height of drain up

Refrigerant
piping

1,000 mm
Option Auto swing (up and Wide-angle
Accessory required for indoor unit. down) and louvers Indoor unit

Navigation Remote Controller


wide-angle louvers (by hand) Drain pump kit

Drain pump kit can be installed


(Wired Remote Controller) (left and right by Soft material
louver bends on either left and right side of
hand) facilitate airflow over a
the indoor unit.
wider area
BRC1E62 even room
Note: Remote controller cable is not
temperature
included and must be procured
locally.
Interlock control
An air discharge Auto-swing 5-level air direction setting
As an energy saving feature, the room air conditioning
modes ensure unit can be interlocked with the key card system.

Wired LCD remote controller comfortable air Using a 3rd-party Lighting

building
distribution across management
Interlock

the entire room system, air


BRC1C61 Gettable to 5
different levels conditioning and
lighting can be
Note: Remote controller cable is not
included and must be procured interlocked.
locally.
* Field setting with remote controller
Comfort even on the far side of the room
To carry air to the far side of long DIII-NET communication standard
Wireless LCD remote controller rooms, extra-high airflow adds 10%
Connection to a centralised control system is available
A signal receiver must be added to the indoor unit. more fan speed the "high" setting.
without option.
Air discharge strength is selected
BRC7EB519 from the remote controller by field
setting.
Easy cleaning
Removable and washable grille
Signal receiver unit (Installed type)
Wireless remote controller is supplied in a Switchable fan speed: High/Middle/Low
set with a signal receiver.

Auto airflow rate (When BRC1E62 is used)


Flat panel, easy to wipe dust off
Non-flocking flaps
Programme "Dry" Condensation does not easily form on and dirt does not
Dehumidification is microprocessor controlled to prevent abrupt and cling to non-flocking flaps.
uncomfortable changes in air temperature. It is easy to clean.
25 26
CEILING MOUNTED BUILT-IN TYPE

Clever and compact mini ducted unit Comfortable Compact


provides comfort and flexibility Flexibly adapts to shop interiors Compact design of built-in type helps blend
with interior decor
To cope with the challenges of L-shaped or U-shaped spaces, it
is possible to install the air discharge unit away from the main unit. Height reduced to allow installation in confined spaces.
At the same time, different types of architectural space can be (mm)
kept comfortable.
FBQ50/60/71B Indoor unit 50B 60/71B
Height 300
Width 700 1,000
Depth 800

L-shaped space U-shaped space Long space


Work & Servicing
The height of the unit is a mere 300 mm. It can be
Two selectable temperature-sensors installed in a narrow ceiling space
Both indoor unit and wired remote controller (option) contain (when access panel is used.)
temperature-sensors. Temperature sensing can be set at the unit
or, to further improve comfort level, closer to the target area at the
Option wired remote control.
This feature requires initial setting by the installer. 300 mm
300mm
Accessory required for indoor unit.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from
another room. **Wireless remote controller does not have a temperature-sensor.
Navigation Remote Controller Access panel
(Wired Remote Controller)

Switchable fan speed: High/Low


BRC1E62 Provided with condensate drain pump, waking drain
Programme "Dry" piping easier in awkward spaces
Note: Remote controller cable is not Dehumidification is microprocessor controlled to prevent abrupt
included and must be procured
locally. and uncomfortable changes in air temperature.
250mm

Wired LCD remote controller Quiet operation dB(A)


Access panel

BRC1C61 Indoor unit


Sound pressure level
High Low
Note: Remote controller cable is not
External static pressure can be set depending on
included and must be procured 50B 33 29 duct length, presence of high-efficiency filter, and
locally.
60B 34 30 other installation conditions
71B 34 30
External static pressure pattern (Pa)
Indoor unit High Standard Low
Wireless LCD remote controller 50B–71B 88 49 20
A signal receiver must be added to the indoor unit. External static pressure is set to standard when the unit is shipped from the factory.

BRC4C62

Signal receiver unit


(Separate type)

Wireless remote controller is supplied in a


set with a signal receiver.

27 28
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Thinner design allows greater Design and installation Using a DC fan motor, the external static
pressure can be controlled to within a range

installation flexibility flexibility


With a height of only 245 mm, installation is
of 50 Pa to 150 Pa
Adjustable external static pressure

NEW
possible even in buildings with narrow ceiling 50 Pa 150 Pa
spaces
FBQ50/60/71/100/125/140E
Set to low static Set to high static pressure for

245mm pressure when ducts


are short.
advanced needs such as when
using dampers and long ducts.

Comfort airflow is achieved in accordance with conditions such


One of the industry’s most compact bodies as duct length.
in the mid-static pressure range.
Indoor unit 50/60/71E 100/125/140E Airflow rate auto adjustment function
Height 245
Controls the airflow rate using a remote controller during test run.
(mm)

Width (mm) 1,000 1,400 It is automatically adjusted to approximately ±10% of the rated H
Depth (mm) 800 tap airflow.

Higher lift is realized by utilising built-in DC


Interlock control
Option drain pump with standard accessory As an energy saving feature, the room air conditioning unit can be
Accessory required for indoor unit. interlocked with the hotel key card system.
Middle & High static
Navigation Remote Controller pressure type Using a 3rd-party building
(Wired Remote Controller)
850mm (FBQ-D series) management system, air
conditioning and lighting can
700mm be interlocked. Interlock
BRC1E62 * Field setting with remote
controller
Note: Remote controller cable is not
included and must be procured
Bottom suction is available
locally.
Wiring and servicing
can be done from the unit
DIII-NET communication standard
joist
underside of the unit (an Easier communication and connection with the centralised control
option part required). system.
Wired LCD remote controller Air suction
ceiling

BRC1C61
Note: Remote controller cable is not
Rear suction Bottom suction
Easy maintenance
Air suction flange Sield plate for side plate(option)
included and must be procured
locally. Position of drain pan inspection opening has
been modified for easier inspection work

Drain pan maintenance check window


Wireless LCD remote controller This makes it possible
A signal receiver must be added to the indoor unit. Control box
Bottom
Switch bottom plate with to inspect for drain pan
cover air suction flange. Air suction
plate flange dirt and to confirm Inspection
BRC4C66 Make the control box
face inward.
Bottom plate
drainage during
opening for
drain pan
installation without the Drain pan
use of tools. maintenance
check window
Signal receiver unit
(Separate type)
Easy maintenance because the drain
Wireless remote controller is supplied in a
set with a signal receiver.
Control box faces outward.
Control box cover
Control box faces inward.
pan can be removed

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) Comfort High efficiency
When air conditioning two rooms Door-installed Wall-installed
Under-door cutout Switchable fan speed:High/Middle/Low and Auto DC fan motor and DC drain pump are utilised
simultaneously, the air discharged into ventilation grille ventilation grille
each room must be circulated back to (“Auto” is applicable when BRC1E62 is used.) to improve energy efficiency
the air conditioner. To achieve this, a
ventilation duct should be installed for
Clean
Ventilates air through
Partitioning wall
the partitioning wall.
each room or one of the indicated (See right)
ventilation grilles should be installed Ventilation grille Ventilation grille Under-door cutout
on the partitioning wall or under the
Note: The under-door cutout method should be used only when there is a small volume of airflow. Silver ion anti-bacterial drain pan
door between the rooms.
A built-in antibacterial treatment that uses silver ion in the drain pan prevents
the growth of slime, bacteria, and mould that cause smells and clogging.
29 30
FLOOR STANDING TYPE

New airflow control for New comfortable airflow control


more comfort 1) Left and right directions (by remote controller)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
(Applicable when BRC1E62 is used.)
Pattern 1 Swing wide across the front Pattern 2 Swing across left side Pattern 3 Swing across right side

FVQ50/60/71/100/125/140C

When installed in the center of a wall. When installed in the corner of a room.

2) Up and down directions (by hand)


Independent up-and-down airflow directions facilitate even room temperature and help save energy.

Freely select Example applications


New unit
both up and Upper louver (1)
When cooling
down airflow Upper interlocking louvers (4)
Turning louvers
BRC1E62
direction with Lower interlocking louvers (2)
and upward
Lower louver (1)
can be 8-louver and leaving
and horizontal
incorporated (horizontal Each set of louvers to will reduce
into the blade) setting. can be independently uneven room
indoor unit. adjusted. (Manual adjustment) temperature.

Comfortable fan speed Quiet operation dB(A)

control Indoor unit


Sound pressure level
50/60/71C 100C 125C 140C

Option
Switchable fan speed: High 43 50 51 53

Accessory required for indoor unit.


High/Middle/Low and Auto Middle 41 47 48 51
("Auto" is applicable when BRC1E62 is used.)
Low 38 44 46 48
Navigation Remote Controller
Auto airflow rate is selectable
(Wired Remote Controller)

BRC1E62
Airflow rate is automatically controlled in accordance with the Quick and easy installation
and maintenance
difference between room temperature and set temperature.

Note: Remote controller cable is not


included and must be procured
locally. High fan speed mode (applicable for FVQ50-100) Lightweight indoor unit
To carry airflow to the far side of the room, airflow rate can be
increased 5% or 10% depending on the installation condition or Enables smooth transport and installation of the indoor unit.
(kg)
customer's request. (Field setting by remote controller.)
Indoor unit 50/60/71C 100C 125C 140C
Wired LCD remote controller Programme "Dry" Weight 39 47
Dehumidification is microprocessor controlled to prevent abrupt
BRC1C61 and uncomfortable changes in air temperature. Long-life filter (standard) requires no
Note: Remote controller cable is not
included and must be procured
maintenance for about 1 year*
locally. The filter is washable and reused after 1 year.

Energy saving * For dust concentration of 0.15 mg/m3


-Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller (filter sign).
-The periodical cleaning time for the filter can be shortened depending on the usage
DC fan motor improves efficiency environment.

Employs a safety lock function of suction grille


The grill will not open even upon impact.

DIII-NET communication standard


Connection to a centralised control system is available
without option.
31 32
OUTDOOR UNIT

NEW
Technology for energy efficiency
Compact Outdoor unit The high efficiency compressor to
achieve a high COP
1 Compressor equiped with Reluctance DC motor
Daikin DC Inverter models are equipped with the Reluctance DC
RZR100MVM 3
motor for compressor.
RZR125MVM
RZR140MVM
The Reluctance DC motor uses 2 different types of torque,
2
RZR50MVM RZR100MYM
neodymium magnet*1 and reluctance torque*2.
RZR60MVM RZR125MYM This motor can save energy because it generates more power with a 1
RZR71MVM RZR140MYM smaller electric power than an AC or previous DC motor.

Easy installation and maintenance Night quiet Reluctance DC Motor


Reluctance
DC motor
operation mode

Motor efficiency
Pre charged for up to 30 metres 4-direction piping offers greater
>> Swing compressor
If the refrigerant piping length does not
exceed 30 m, there is no need for on-site
layout freedom (RZR100-140 only) The Automatic night quiet
DC motor

The outer panel for the piping connection part


More than 20% Energy savings is
gas charging.
of the front, right side and backside can be mode will initiate 8 hours AC motor
realised, eliminating the
removed and is easier for post-installation after the peak temperature friction and the leakage
piping work.
is reached in the daytime, of refrigerant gas.
Long piping length and normal operation will
Removable part of Rotational speed Swing bushing

Allowed refrigerant piping length bottom frame makes resume 10 hours after that Small load
Low capacity
Large load
High capacity
Refrigerant gas

and level difference Separation Reducing noise will reduce capacity slightly.
the piping work easier available
1
*1. A neodymium magnet is approximately 10
times stronger than a standard ferrite
ALL model Sound pressure level (dB(A)) Note: Data are based on studies conducted under magnet.
controlled conditions at a Daikin laboratory.
Facilitates pump down
*2. The torque created by the change in power
Rated2 Night Quiet Mode between the iron and magnet parts.
Pre charged1 30 m
(Refrigerant recovery function) RZR50/60/71MVM 48 44
Piston by incorporated
50 m A pump-down switch is provided to make it RZR100MVM/MYM 49 45 blade and roller.
Max. length (Equivalent length 70m) easier to collect refrigerant if the unit is to be RZR125MVM/MYM 52 45
moved or layout modified. RZR140MVM/MYM 54 45
Max. level
difference 30 m *Pump-down function is available for pre-charged refrigerant Note : 1Anechoic chamber conversion value, measured according
amount. to JIS parameters and criteria. During operation these
Note : 1Additional refrigerant charging is
Low gas pressure detection function 2
values are somewhat higher owing to ambient conditions.
Value when cooling. Value will differ when heating.
2 Fan
required if the refrigerant pipe is
longer than the length. Effective gas monitoring reduces the labor required Peak outdoor temperature V-cut Propeller Fan (RZR50-71M) Aero Spiral Fan (RZR100-140M)
for operation, maintenance, and repairs.
Through use of a V-cut propeller fan that imitates The Aero Spiral Fan features fan blades with the
Capacity (%)

100 the efficiency of the swan, a migratory bird, bent blade edges, further reducing turbulence.
Compact and lightweight 50
8 hours
10 hours
airflow becomes smooth and loss is reduced.
With the bent Without the bent
Reduced installation work thanks to blade edge blade edge
Load (%)

light, compact outdoor unit. 0


Reduced by
48
355 mm
Sound (dB(A))

Comparison of outdoor units Rated

990
Operation

R48NUY1 NEW RZR140MYM


Quiet mode
mm Reduced by 44 Quiet mode
19 kg
Height 1,345 mm 990 mm 8:00 12:00 16:00 20:00 0:00 4:00 8:00
Weight 92 kg 73 kg Note : Daikin date for RZR71MVM
Escaping eddies are sucked
R48NUY1 RZR140MYM Operating sound about 4 dB quieter
Φ550 Imitating the performance in by the bent blade edges,
V-cut propeller fan of the swan reducing overall turbulence.
Durability Demand Control Function
As the bottom frame is subject to corrosion, a By setting limits that restrict power 3 DC fan motor
corrosion-proof galvarium steel plate is consumption, you can cut electricity bills Efficiency improved in all areas compared to AC DC fan motor structure
adopted to enhance the durability Maximum power use is
(RZR100-140 only)
motors, especially at low speeds.
maintained within a set
Heat exchange fins are provided with level of system capacity. * Field setting
* Required for KRP58M51 (Option)
anti-corrosion treatment (RZR50-71M) This enables effective Limitation
consumption

demand control while


Power

Construction maintaining comfort.


Maximum power
Non-treated fin Aluminium
consumption can be set
Hydrophilic treatment at 40, 60, 70, 80, or 100%. 8:00 12:00 20:00Time
Anti corrosion Aluminium
16:00

treated fin Corrosion resistant resin

33 34
REMOTE CONTROLLER Optional accessory

Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units.
Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller Wired LCD remote controller


Wired remote controller has
(Wired LCD Remote Controller) Easy to read because of large LCD screen.
built-in temperature-sensor
The rubber switch and the (Applies to wired remote controllers (BRC1C61/1E62))
oil-resistant plastic casing are
NEW This simple, modern designed remote controller with fresh adopted for durability.
Enables temperature sensing closer to target
area for improved comfort. (When using remote
white colour matches your interior design. Operation is Only 17 mm thick. Can be control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
much easier and smoother, just follow the indications on installed either recessed or
exposed.
the navigation remote controller.
Facilitates maintenance and repair
All initial settings can be set from the remote
controller. After interior construction is complete,
BRC1E62 BRC1C61 ceiling mounted cassette type can be remotely
set without having to use stepladder access for
manual setting.
Clear Display Setting contents: High ceiling use, air direction, filter type, address
Wireless LCD remote controller for centralised control (group control address is set automatically).

Dot matrix display Backlight Remote controller is equipped with model name
A combination of fine dots display The wireless remote controller is and failure display functions. This facilitates
enables various icons. supplied in a set with a signal service in the unlikely event of a malfunction.
receiver. (Model name display function applies to BRC1E62 only.)
Large text display is easy to
see. Signal receiver unit is contained
inside decoration panel or indoor
unit. SkyAir shares common control with
Shape of signal receiver unit Heat Reclaim Ventilator and the
differs according to the indoor other Daikin air-conditioning units,
unit. thus simplifying interlocking
Energy saving BRC7F635F
operations.
NEW Setpoint auto reset NEW Setpoint range set Signal receiver unit Easily adaptable to large-scale, high-function,
Wireless remote (For ceiling mounted Note: The signal receiver unit shown in the
controller
centralised remote control systems.
cassette type)
- Even if the set temperature is changed, after a preset period new set - Saves energy by limiting the photograph is for mounting inside
Installing and connecting control wiring between
the decoration panel of the ceiling
temperature returns to preset value. min. and max. set temperature. mounted cassette type. SkyAir and other Daikin air-conditioning
- Period selectable from 30, 60, 90, or 120 min. - Avoids excessive heating or equipment is easy.
Restaurant example cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient if the Wireless remote controller for each indoor unit type
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset remote controller is installed CEILING MOUNTED CASSETTE TYPE BRC7F635F
crowded room temperature (27ºC)
Returns to where anyone can change the COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE BRC7E531W
27°C 24°C 27 °C
automatically
settings. CEILING SUSPENDED TYPE BRC7GA56
WALL MOUNTED TYPE BRC7EB519
CEILING MOUNTED BUILT-IN TYPE BRC4C62
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C66
*Preset-return time can be set

Off timer (programmed)


at 30, 60, 90, or 120 min

- Sets and saves setting for an increment of time that automatically turns off air LCD panel shows operating status in letters, numbers, and motion.
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments. Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
Convenience Programming time display
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Weekly schedule Multilingual display
- 5 actions per day can be scheduled for each day Display is available in 11
of the week. languages.
- The holiday function will disable schedule timer (English, German, French, Spanish,
for the days that have been set as holiday. Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
NEW - 3 independent schedules can be set.
(e.g. summer, winter, mid-season)

35 36
REMOTE CONTROLLER Optional accessory Simultaneous operation system Twin Multi operation

System variation to control multiple indoor units


Control pattern Wired remote controller
LCD REMOTE CONTROLLER
Wireless remote controller
Four types of Multi series indoor units
Control by 1 (Basic system)
are available
remote controller
Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit

Control by 1 wireless remote


For control from 2 controller and 1 wired remote
Control by 2 locations such as in controller (See note 2, 3)
remote controllers room and control room, Signal receiver unit installed
Connects 2 wired remote
exits, etc. on indoor unit
controllers (See note 1) Branch piping kit Branch piping kit

FCQ60/71KAVEA X2 FHQ60/70DAVMA X2
For simultaneous specifications Page 43 specifications Page 45
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit

Operation and monitoring


Control by is carried out using the (Command from outside) (Command from outside)
contact signal from the
external command operation control box in
the monitoring room. Optional wiring adaptor for Optional wiring adaptor for Branch piping kit
electrical appendices is necessary electrical appendices is necessary
Branch
FVQ60CVE X2 piping kit
Central remote controller (option)
FBQ60/71EVE X2 FVQ71CVEB X2
Central remote controller (option)
specifications Page 47 specifications Page 48
Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.

Twin Multi for comfort and


Heat Reclaim Heat Reclaim
saving outdoor space
Ventilator Ventilator
Link by remote
controller group control.
Can be operated simultaneously Can be operated simultaneously Distributed indoor units
or independently by remote controller
(set by ventilation mode)
by remote controller
(set by ventilation mode) enhance comfort
Interlock control
with Heat Reclaim Central remote controller (option) Central remote controller (option)
Reduced outdoor unit
Ventilator installation space
Zone link control by For example, four
centralised control. Heat Reclaim Heat Reclaim indoor units are judiciously
Ventilator Ventilator
spaced in this wide single-floor
Heat Reclaim Ventilator for indoor units within a zone are operated by Heat Reclaim Ventilator for indoor units within a 2 sets of restaurant to deliver comfortable
interlocking Can also be operated independently by remote controller. zone are operated by interlocking Twin Multi currents of air to every
Note: 1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.
corner of the room.

Piping guideline
Easily adaptable to large-scale, high-function, centralised remote control system. RZR125/140LVVM
Outdoor unit Refrigerant branch piping
Central remote controller Unified on/off controller Schedule timer RZR125/140LUY1 Indoor
kit for Twin Multi
unit
DCS601C51 (Option) Max. piping length L0 L1 L2 60 m operation (option)
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)
One-way max. piping length Indoor unit KHRP58P216T Page 52

H1
L0 L1 50 m
(longest length of liquid piping
(In case of L1 L2)
or gas piping)
L2 Branch
Max. branch piping length L1, L2 20 m piping
Branch piping

H
Max. difference of branch L1 L2 10 m
Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full piping length (In case of L1 L2) L1
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir Max. level difference between
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways. H1 0.5 m Main piping
indoor units L0

Max. level difference between H 30 m Outdoor unit


outdoor unit and indoor units

37 38
FUNCTIONS

Functions
COMPACT MULTI FLOW CEILING WALL MOUNTED CEILING MOUNTED DUCT CONNECTION MIDDLE STATIC
CEILING MOUNTED CASSETTE TYPE Round Flow MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE TYPE BUILT-IN TYPE PRESSURE TYPE FLOOR STANDING TYPE

overview Indoor unit FCQ50-140KAVEA FCQ60/71/125/140KAVEA FFQ25-60BV1B FHQ50-140DAVMA FHQ60/71/125/140DAVMA FAQ100CVEA FBQ50-71BV1A FBQ50-140EVE FBQ60/71/125/140EVE
FVQ50/60CVE
FVQ60/71/125/140CVEB
FVQ71-140CVEB
Cooling only
Outdoor unit RZR50-140MVM RZR125/140LVVM RZR50-140MVM RZR125/140LVVM RZR100MVM RZR50-140MVM RZR125/140LVVM RZR50-140MVM RZR125/140LVVM
RKS25-60AVMG RXS50-71F(A)VMA
RZR100-140MYM RZR125/140LUY1 RZR100-140MYM RZR125/140LUY1 RZR100MYM RZR100-140MYM RZR125/140LUY1 RZR100-140MYM RZR125/140LUY1
Auto swing
Swing pattern selection
Independent up-and-down airflow
DC fan mortor (Indoor unit)
Switchable fan speed 3step 3step 2step 3step 3step 3step 2step 3step 3step 3step 3step
Auto airflow rate *3 *3 *3 *3 *3
Comfort
High fan speed mode *5 *5
Programme “Dry”
High ceiling application *6 *6
Two selectable temperature-sensors *1
Year-round cooling applicable *7 *7
Night quiet operation *2

Setpoint auto reset *3


Setpoint range set *3
Remote Weekly schedule timer *3
Controller
Off timer (programmed) *3
On/Off timer *4

Anti-bacterial air filter *8 *8


Mould-proof air filter
Cleanliness
Silver ion anti-bacterial drain pan
Mould-proof drain pan

Drain pump mechanism *8 *8 *8


Pre-charged for up to 30 m *2
Pre-charged for up to 10 m *2
Long-life filter *8 *8
Work & Filter sign
servicing
Ceiling soiling prevention
Low gas pressure detection *2
Emergency operation
Self-diagnosis function

Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
Control External command control *8 *8 *8 *8 *8 *8 *8 *8 *8 *8 *8
features *8 *8
Central remote control
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard

High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit

Simultaneous Twin multi operation *9 *9 *9 *9


Others
Anti corrosion treated heat exchangers *2 *10 *10 *10 *10

Note: *1 : Applicable when wired remote controller is used *4 : Applicable when BRC1C61 is used *7 : Applicable when outdoor temperature is from 10 to 46℃DB *10 : RZR50-71 only
*2 : For outdoor units *5 : Applicable for FVQ50-100 *8 : Option
*3 : Applicable when BRC1E62 is used *6 : Installable on max. 3.5 m(50-71) and 4.3 m (100-140) high ceiling *9 : Applicable for 60/71 class indoor unit

39 40
FUNCTIONS

Abundance of functions that provide comfortable


air-conditioning in stores and offices. Work and Servicing
Note: Some features only available on selected models. See overview pages for full list of features applicable to each unit. Drain pump mechanism Ceiling soiling prevention
Steeper gradient realises more Daikin's innovative air discharge mechanism keeps airflow away from

Comfort efficient condensate drainage.


High-lift is especially useful for long
the ceiling. Ceiling cleaning is less frequently required.

lengths of drain piping.


Auto-swing Programme "Dry" Low gas pressure detection
Insufficient gas charging is normally hard to detect. During test
Delivers comfortable The air flow direction can be Dehumidification is microprocessor controlled to prevent abrupt and Pre charged for up to 30 m run after installation and regular inspection, the refrigerant level
air-conditioning to all areas, near to fixed at your desired angle by uncomfortable changes in air temperature. Useful for reducing
and far from the air-conditioner. the remote controller. uncomfortable humidity without uncomfortable cooling of the room. If refrigerant piping length does not exceed 30 m, there is no need is monitored by a microprocessor to maintain proper gas
for on-site gas charging. pressure. Reliability is assured and maintenance and inspection
can be carried out more quickly.
High-ceiling application
*Applicable to RZR series.

Swing pattern selection RKS/RXS series: 10 m

Delivers Emergency operation


You can freely set air discharge settings by remote controller. air-conditioning Long-life filter
Even if there is a malfunction elsewhere in the system, the fan or
(1) Standard (2) Draft prevention (3) Ceiling soiling comfort all the way Maintenance is not required for one year*.
down to the floor in
compressor can still be operated. (depending on the malfunction)
setting setting prevention setting The filter is washable and can be reused.
air-conditioning zones
with high ceilings.
*For dust concentration of 0.15 mg/m3
Self-diagnosis function
Filter sign The operating parameters of indoor and outdoor units, and sensor
Note:When units are installed on high ceilings, depending on the model, various data at critical locations throughout the system, are constantly
restrictions concerning maximum height, air discharge direction, and choice of The filter sign warns you when it is time to clean the filter. monitored using a microcomputer. To facilitate quick response in the
options may apply. event of a malfunction, a message appears on the LCD of the remote
Independent up-and-down airflow *When using a wired remote controller the sign is displayed in the LCD. When using
a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. controller and an LED on the unit illuminates.
Independently adjust (manually) the eight horizontal blade louvers in Two selectable temperature-sensors
Control features
both up and down directions to achieve an airflow that reduces
uneven room temperature. Temperature-sensors are included in the indoor unit and optional
wired remote controller. Temperature sensing closer to target area is
possible to further increase the
DC fan motor (indoor unit) comfort level. Auto-restart Central remote control
Use the temperature-sensor in the If there is a power outage while the equipment is operating, Optional central remote controller enables centralised control of
DC fan motor improves efficiency. indoor unit when controlling air
conditioning from another room. operations will restart in the same mode as before the power cut up to 1024 indoor units (64 groups) from up to 1 km away.
when electricity is restored.
Switchable fan speed Note: Wireless remote controllers have no
temperature-sensor.
High setting provides maximum reach while low setting minimises drafts. Control by 2 remote controllers Interlock control with Heat Reclaim Ventilator
Year-round cooling applicable Using 2 remote controllers you can operate the equipment locally or Enables interlocking control with external equipment such as Heat
from a remote location. Reclaim Ventilator.
Auto airflow rate Efficient cooling even in winter when the indoor temperatures are
higher than those outside, such as in underground public spaces or Note: When a wireless remote controller is used, remote control by two remote
Airflow rate is automatically controlled in accordance with the offices with many computers.
controllers is not possible.
difference between room temperature and set temperature.

Night quiet operation Group control by 1 remote controller DIII-NET communication standard
High fan speed mode The Automatic night quiet mode will initiate 8 hours after the peak
You can turn up to 16 indoor units on/off with a single remote Standardly equipped interface enables connection to centralised
controller. (When using connected indoor units, the settings must all control system without need of an adaptor.
You can increase fan speed approximately 10% higher than the temperature is reached in the daytime, and normal operation will
be the same and on/off will be simultaneous.)
"high" setting. resume 10 hours after that.

External command control


Remote Controller Operation and monitoring is carried out using the contact signal
from the operation control box in the building monitoring room.
Setpoint auto reset Off timer (programmed) *An option is required.

Options
Even if the set temperature is changed, after a preset period Sets and saves setting for an increment of time that automatically
new set temperature returns to preset value. turns off air conditioner after a preset period of time for each time
operation starts.
Setpoint range set
On/Off timer High-efficiency filter Fresh-air intake kit
Saves energy by limiting the minimum and maximum set
temperatures. Avoids excessive heating and cooling. Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside. Convenient
Operation starts when the preset time of the ON timer elapses and
stops when the preset time of the OFF timer elapses. for places where a ventilation fan cannot be installed.
Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per day for Ultra long-life filter
each day of the week. Not only can the time be set for the operation Requires no maintenance for about 4 years* (10,000h) in stores and
ON setting, but also the temperature. offices.
*For dust concentration of 0.15 mg/m3

Cleanliness
Anti-bacterial air filter Silver ion anti-bacterial drain pan Others
The air filter has an anti-bacterial treatment to help prevent the A built-in antibacterial treatment that uses silver ion in the drain Simultaneous Twin multi operation Anti corrosion treated heat exchangers
growth of bacteria and mould on it. pan prevents the growth of slime, bacteria, and mould that cause
smells and clogging. Distributed indoor units enhance comfort. To achieve increased durability by improved resistance to salt
Reduced outdoor unit installation space. corrosion and atmospheric pollution, Anti corrosion treated fin for
Mould-proof air filter Mould-proof drain pan heat exchangers (with special coating) are used for the heat
Sanitary filter has mould-resistant treatment. Mould-proof drain pan prevents growth of mould in highly humid exchanger of the outdoor unit. In high corrosive areas, regular
conditions. maintenance needs to be carried out.

41 42
SPECIFICATIONS

CEILING MOUNTED CASSETTE TYPE COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
50 60 71 100 125 140 100 125 140 25 35 50 60
Model Indoor unit FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Model Indoor unit FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Name Name Outdoor unit
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Cooling capacity1 2.5 3.4 4.7 5.8
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) Rated (Min. - Max.)
kW (1.2-3.0) (1.2-3.7) (1.7-5.6) (1.7-6.0)
Rated (Min. - Max.)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 8,500 11,600 16,000 19,800
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) Btu/h (4,100-10,250) (4,100-12,600) (5,800-19,100) (5,800-20,500)
Power consumption Cooling1 kW 1.24 1.58 1.99 2.78 4.31 5.62 2.78 4.31 5.62 Power consumption Cooling1 kW 0.73 1.10 1.62 2.07
COP W/W 4.03 3.80 3.57 3.60 2.90 2.49 3.60 2.90 2.49 COP W/W 3.42 3.09 2.90 2.80
CSPF Wh/Wh 6.47 6.19 5.99 5.13 5.00 4.85 5.13 5.00 4.85 Colour Unit ----------
Indoor
Indoor Colour Unit ---------- Decoration panel White
unit
unit Decoration panel Fresh white Airflow rate (H/L) m3/min 9/6.5 10/6.5 12/8 15/10
Airflow rate (H/M/L) m3/min 21/17.5/13.5 32/26/20 33/28/22.5 32/26/20 33/28/22.5 cfm 317/229 353/229 423/282 529/353
cfm 741/618/477 1,130/918/706 1,165/988/794 1,130/918/706 1,165/988/794 Sound pressure level2 (H/L) dB(A) 29.5/24.5 32/25 36/27 41/32
Sound pressure level 3 (H/M/L) dB(A) 35/31.5/28 43/37.5/32 44/39/34 44/40/36 43/37.5/32 44/39/34 44/40/36 Dimensions Unit mm 286X575X575
Dimensions Unit mm 256X840X840 298X840X840 (HXWXD) Decoration panel mm 55X700X700
(HXWXD) Decoration panel mm 50X950X950 Machine weight Unit kg 17.5
Machine Unit kg 21 24 Decoration panel kg 2.7
weight Decoration panel kg 5.5 Certified operation range °CWB 14 to 23
Certified Operation range °CWB 14 to 25 Colour Ivory white
Outdoor
Outdoor Colour Ivory white Coil Type Cross fin coil
unit
unit Coil Type Cross fin coil Micro channel Compressor Type Hermetically sealed swing type
Compressor Type Hermetically sealed swing type Motor output kW 0.6 1.1
Motor output kW 1.12 1.35 1.76 2.03 1.92 Refrigerant charge (R-410A) 1.0 1.5
kg
Refrigerant charge (R-410A) kg 1.6(Charged for 30 m) 1.9(Charged for 30 m) (Charged for 10 m) (Charged for 10 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54 Sound pressure level2 dB(A) 46 47 49
level3 Night quiet mode dB(A) 44 45 Dimensions (HXWXD) mm 550X765X285 735X825X300
Dimensions (HXWXD) mm 595X845X300 990X940X320 Machine weight kg 34 47
Machine weight kg 43 65 73 Certified operation range °CDB 10 to 46
Certified Operation range °CDB 21 to 46 Piping Liquid (Flare) mm φ6.4
Piping Liquid (Flare) mm φ9.5 connections Gas (Flare) mm φ9.5 φ12.7
connections Gas (Flare) mm φ15.9 Drain Indoor unit mm VP20 (I.D φ20XO.D φ26)
Drain Indoor unit mm VP25 (I.Dφ25XO.D φ32) Outdoor unit mm φ18.0 (Hole)
Outdoor unit mm φ26.0 (Hole) Max. interunit piping length m 20 30
Max. interunit piping length m 50 (Equivalent length 70) Max. installation level difference m 15 20
Max. installation level difference m 30 Heat insulation Both liquid and gas piping
Heat insulation Both liquid and gas piping Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

125 140 125 140 125 140 125 140


Model Indoor unit FCQ125KAVEA FCQ140KAVEA FCQ60KAVEAx2 FCQ71KAVEAx2 FCQ125KAVEA FCQ140KAVEA FCQ60KAVEAx2 FCQ71KAVEAx2
Name Outdoor unit RZR125LVVM RZR140LVVM RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 RZR125LUY1 RZR140LUY1
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 14.0 12.5 14.0 12.5 14.0 12.5 14.0
kW
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)

Btu/h 42,700 47,800 42,700 47,800 42,700 47,800 42,700 47,800


(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 3.68 4.91 3.68 4.91 3.68 4.91 3.68 4.91
COP W/W 3.40 2.85 3.40 2.85 3.40 2.85 3.40 2.85
Indoor Colour Unit ----------
unit Decoration panel Fresh white
Airflow rate (H/M/L) m3/min 33/28/22.5 21/17.5/13.5 33/28/22.5 21/17.5/13.5
cfm 1,165/988/794 741/618/477 1,165/988/794 741/618/477
Sound pressure level 3 (H/M/L) dB(A) 44/39/34 44/40/36 35/31.5/28 44/39/34 44/40/36 35/31.5/28
Dimensions Unit mm 298X840X840 256X840X840 298X840X840 256X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 24 21 24 21
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Cross fin coil
Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.4 3.1 2.4 3.1
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
Sound pressure Cooling dB(A) 50
level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
Machine weight kg 97
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm φ9.5
connections Gas (Flare) mm φ15.9
Drain Indoor unit mm VP25 (I.Dφ25XO.D φ32)
Outdoor unit mm φ26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

43 44
SPECIFICATIONS

CEILING SUSPENDED TYPE WALL MOUNTED TYPE


50 60 71 100 125 140 100 125 140 100 100
Model Indoor unit FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA Model Indoor unit FAQ100CVEA FAQ100CVEA
Name Name
Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM Outdoor unit RZR100MVM RZR100MYM
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Cooling capacity1,2 10.0
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) kW (5.0-11.2)
Rated (Min. - Max.) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) Rated (Min. - Max.)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 34,100
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) Btu/h (17,100-38,200)
(21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
Power consumption Cooling 1 kW 1.24 1.58 2.37 3.03 4.42 5.55 3.03 4.42 5.55 Power consumption Cooling1 kW 3.37
COP W/W 4.03 3.80 3.00 3.30 2.83 2.52 3.30 2.83 2.52 COP W/W 2.97
CSPF Wh/Wh 6.18 5.99 5.74 5.01 4.99 4.69 5.01 4.99 4.69 CSPF Wh/Wh 4.01
Colour white Colour Fresh white
Indoor Indoor
Airflow rate (H/M/L) m3/min 15/12/10 20.5/17/14 28/24/20 31/27/23 34/29/24 28/24/20 31/27/23 34/29/24 Airflow rate (H/M/L) m3/min 26/23/19
unit unit
cfm 530/424/353 724/600/494 988/847/706 1,094/953/812 1,200/1,024/847 988/847/706 1,094/953/812 1,200/1,024/847 cfm 918/812/671
Sound pressure level3 (H/M/L) dB(A) 37/35/32 38/36/34 42/38/34 44/41/37 46/42/38 42/38/34 44/41/37 46/42/38 Sound pressure level3 (H/M/L) dB(A) 49/45/41
Dimensions (HXWXD) mm 235X960X690 235X1,270X690 235X1,590X690 Dimensions (HXWXD) mm 340X1,200X240
Machine weight kg 25 32 38 Machine weight kg 17
Certified operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Colour Ivory white Colour Ivory white
Outdoor Outdoor
Coil Type Cross fin coil Micro channel Coil Type Micro channel
unit unit
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92 Motor output kW 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m) Refrigerant charge (R-410A) kg 1.9 (Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54 Sound pressure Cooling dB(A) 49
level3 Night quiet mode dB(A) 44 45 level 3 Night quiet mode dB(A) 45
Dimensions (HXWXD) mm 595X845X300 990X940X320 Dimensions (HXWXD) mm 990X940X320
Machine weight kg 43 65 73 Machine weight kg 65 73
Certified operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm φ9.5 Piping Liquid (Flare) mm φ9.5
connections Gas (Flare) mm φ15.9 connections Gas (Flare) mm φ15.9
Drain Indoor unit mm VP20 (I.Dφ20XO.Dφ26) Drain Indoor unit mm VP13 (O.D φ18 X I.D φ13)
Outdoor unit mm φ26.0 (Hole) Outdoor unit mm φ26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70m)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

CEILING MOUNTED BUILT-IN TYPE


125 140 125 140 125 140 125 140 50 60 71
Model Indoor unit FHQ125DAVMA FHQ140DAVMA FHQ60DAVMAx2 FHQ71DAVMAx2 FHQ125DAVMA FHQ140DAVMA FHQ60DAVMAx2 FHQ71DAVMAx2 Model Indoor unit FBQ50BV1A FBQ60BV1A FBQ71BV1A
Name Outdoor unit RZR125LVVM RZR140LVVM RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 RZR125LUY1 RZR140LUY1 Name Outdoor unit RXS50FAVMA RXS60FVMA RXS71FVMA
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz
Cooling capacity1,2 12.5 13.3 12.5 13.3 12.5 13.3 12.5 13.3 Cooling capacity1 5.0 5.7 6.7
kW kW (1.7-5.6) (1.7-7.0) (2.3-8.0)
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) Rated (Min. - Max.)
42,700 45,000 42,700 45,000 42,700 45,000 42,700 45,000 17,100 19,400 22,900
Btu/h Btu/h (5,800-19,100) (5,800-23,900) (7,900-27,300)
(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 2.83
4.00 2.52
4.68 2.83
4.00 2.52
4.68 2.83
4.00 2.52
4.68 2.83
4.00 2.52
4.68 Power consumption Cooling1 kW 1.98 2.23 2.57
COP W/W 3.12 2.84 3.12 2.84 3.12 2.84 3.12 2.84 COP W/W 2.53 2.56 2.61
Colour White Colour ----------
Indoor Indoor
unit Airflow rate (H/M/L) m3/min 31/27/23 34/29/24 15/12/10 20.5/17/14 31/27/23 34/29/24 15/12/10 20.5/17/14 Airflow rate (H/L) m3/min 13/9 18/13
unit
cfm 1,094/953/812 1,200/1,024/847 530/424/353 724/600/494 1,094/953/812 1,200/1,024/847 530/424/353 724/600/494 cfm 459/318 636/459
Sound pressure level3 (H/M/L) dB(A) 44/41/37 46/42/38 37/35/32 38/36/34 44/41/37 46/42/38 37/35/32 38/36/34 External static pressure
(High-Standard-Low) Pa 88-49-20 2
Dimensions (HXWXD) mm 235X1590X690 235X960X690 235X1,270X690 235X1590X690 235X960X690 235X1,270X690
Machine weight kg 38 25 32 38 25 32 Sound pressure level (H/L)
3
dB(A) 33/29 34/30
Certified operation range °CWB 14 to 25 Dimensions (HXWXD) mm 300X700X800 300X1000X800
Colour Ivory white Machine weight kg 34 41
Outdoor
unit Coil Type Cross fin coil Certified Operation range °CWB 14 to 25
Compressor Type Hermetically sealed scroll type Colour Ivory white
Outdoor
Motor output kW 2.4 3.1 2.4 3.1 2.4
2.6 3.1
2.9 2.4 3.1
2.9 Coil Type Cross fin coil
unit
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7(Charged for 30 m) Compressor Type Hermetically sealed swing type
Sound pressure Cooling dB(A) 50 Motor output kW 1.1 1.92
level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46 Refrigerant charge (R-410A) kg 1.5 (Charged for 10 m) 2.3 (Charged for 10 m)
Dimensions (HXWXD) mm 1,170X900X320 Sound pressure level3 dB(A) 47 49 52
Machine weight kg 97 Dimensions (HXWXD) mm 735X825X300 770X900X320
Certified operation range °CDB 21 to 46 Machine weight kg 48 71
Piping Liquid (Flare) mm φ9.5 Certified Operation range °CDB 10 to 46
connections Gas (Flare) mm φ15.9 Piping Liquid mm φ6.4
Drain Indoor unit mm VP20 (I.Dφ20XO.D φ26) connections Gas mm φ12.7 φ15.9
Outdoor unit mm φ26.0 (Hole) Drain Indoor unit mm VP25 (I.Dφ25XO.Dφ32)
Max. interunit piping length m 50 (Equivalent length 70) Outdoor unit mm φ18.0 (Hole) φ26.0 (Hole)
Max. installation level difference m 30 Max. interunit piping length m 30
Heat insulation Both liquid and gas piping Max. installation level difference m 20
Note : Heat insulation Both liquid and gas piping
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2 Note :
Capacities are net, including a deduction for cooling for indoor fan motor heat. 1
3 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 2
Initial setting is standard.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

45 46
SPECIFICATIONS

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FLOOR STANDING TYPE


50 60 71 100 125 140 100 125 140 50 60 71 100 125 140 100 125 140
Model Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE FBQ100EVE FBQ125EVE FBQ140EVE Model Indoor unit FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Name Outdoor unit Name
RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM Outdoor unit RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM
Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0
kW
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Rated (Min. - Max.) (2.3-5,6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4)
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.) 17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800
Btu/h
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) Power consumption Cooling1 kW 1.27 1.84 2.58 3.28 4.62 5.89 3.28 4.62 5.89
Power consumption Cooling1 kW 1.39 1.69 2.22 2.82 4.58 5.85 2.82 4.58 5.85 COP W/W 3.94 3.26 2.75 3.05 2.71 2.38 3.05 2.71 2.38
COP W/W 3.60 3.56 3.20 3.55 2.73 2.39 3.55 2.73 2.39 CSPF Wh/Wh 5.91 4.76 4.33 4.07 4.58 4.10 4.07 4.58 4.10
CSPF Wh/Wh 5.40 5.20 5.04 4.73 4.61 4.38 4.73 4.61 4.38 Indoor Colour Fresh white
Indoor Colour ---------- unit Fan Airflow rate (H/M/L) m /min
3
18/16/14 28/25/22 28/26/24 30/28/26 28/25/22 28/26/24 30/28/26
unit Fan Airflow rate (H/M/L) m3/min 18/15/12.5 23/19.5/16 32/27/22.5 36/30.5/25 32/27/22.5 36/30.5/25 cfm 635/565/494 988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918
cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 1,130/953/794 1,271/1,077/883 Sound pressure level3 (H/M/L) dB(A) 43/41/38 50/47/44 51/48/46 53/51/48 50/47/44 51/48/46 53/51/48
External static pressure3 Pa Rated 50 (50-150) Dimensions (HXWXD) mm 1,850X600X270 1,850X600X350
Sound pressure level4 (H/M/L) dB(A) 35/33/31 38/35/33 38/35.5/33 40/37.5/35 38/35.5/33 40/37.5/35 Machine weight kg 39 47
Air filter5 ---------- Certified Operation range °CWB 14 to 25
Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800 Colour Ivory white
Outdoor
Machine weight kg 37 47 unit Coil Type Cross fin coil Micro channel
Certified Operation range °CWB 14 to 25 Compressor Type Hermetically sealed swing type
Colour Ivory white Motor output kW 1.12 1.35 1.76 2.03 1.92
Outdoor
unit Coil Type Cross fin coil Micro channel Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9 (Charged for 30 m)
Compressor Type Hermetically sealed swing type Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
Motor output kW 1.12 1.35 1.76 2.03 1.92 level3 Night quiet mode dB(A) 44 45
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m) Dimensions (HXWXD) mm 595X845X300 990X940X320
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54 Machine weight kg 43 65 73
level4 Night quiet mode dB(A) 44 45 Certified Operation range °CDB 21 to 46
Dimensions (HXWXD) mm 595X845X300 990X940X320 Piping Liquid (Flare) mm φ9.5
Machine weight kg 43 65 73 connections Gas (Flare) mm φ15.9
Certified Operation range °CDB 21 to 46 Drain Indoor unit mm VP20 (I.D φ20XO.D φ26)
Piping Liquid (Flare) mm φ9.5 Outdoor unit mm φ26.0 (Hole)
connections Gas (Flare) mm φ15.9 Max. interunit piping length m 50 (Equivalent length 70)
Drain Indoor unit mm VP25 (I.Dφ25XO.Dφ32) Max. installation level difference m 30
Outdoor unit mm φ26.0 (Hole) Heat insulation Both liquid and gas piping
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

125 140 125 140 125 140 125 140 125 140 125 140 125 140 125 140
Model Indoor unit FBQ125EVE FBQ140EVE FBQ60EVEx2 FBQ71EVEx2 FBQ125EVE FBQ140EVE FBQ60EVEx2 FBQ71EVEx2 Model Indoor unit FVQ125CVEB FVQ140CVEB FVQ60CVEx2 FVQ71CVEBx2 FVQ125CVEB FVQ140CVEB FVQ60CVEx2 FVQ71CVEBx2
Name Outdoor unit Name Outdoor unit
RZR125LVVM RZR140LVVM RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 RZR125LUY1 RZR140LUY1 RZR125LVVM RZR140LVVM RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 RZR125LUY1 RZR140LUY1
Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Cooling capacity1,2 12.5 13.5 12.5 13.5 12.5 13.5 12.5 13.5
kW
Cooling capacity1,2 12.5 14.0 12.5 14.0 12.5 14.0 12.5 14.0 Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
kW (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.) 42,700 46,100 42,700 46,100 42,700 46,100 42,700 46,100
Btu/h
42,700 47,800 42,700 47,800 42,700 47,800 42,700 47,800 (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Btu/h (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) Power consumption Cooling1 kW 4.39 5.40 4.39 5.40 4.39 5.40 4.39 5.40
Power consumption Cooling1 kW 3.73 4.71 3.73 4.71 3.73 4.71 3.73 4.71 COP W/W 2.85 2.50 2.85 2.50 2.85 2.50 2.85 2.50
COP W/W 3.35 2.97 3.35 2.97 3.35 2.97 3.35 2.97 Indoor Colour Fresh white
Indoor Colour ---------- unit Fan Airflow rate (H/M/L) m3/min 28/26/24 30/28/26 18/16/14 28/26/24 30/28/26 18/16/14
unit Fan Airflow rate (H/M/L) m3/min 36/30.5/25 18/15/12.5
23/19.5/16 36/30.5/25 18/15/12.5 23/19.5/16 cfm 988/918/847 1,059/988/918 635/565/494 988/918/847 1,059/988/918 635/565/494
cfm 1,271/1,077/883 635/530/441
812/688/565 1,271/1,077/883 635/530/441 812/688/565 Sound pressure level3 (H/M/L) dB(A) 51/48/46 53/51/48 43/41/38 51/48/46 53/51/48 43/41/38
External static pressure3 Pa Rated 50 (50-150) Dimensions (HXWXD) mm 1,850X600X350 1,850X600X270 1,850X600X350 1,850X600X270
Sound pressure level4 (H/M/L) dB(A) 40/37.5/35 35/33/31 38/35/33 40/37.5/35 35/33/31 38/35/33 Machine weight kg 47 39 47 39
Air filter5 ---------- Certified Operation range °CWB 14 to 25
Dimensions (HXWXD) mm 245X1,400X800 245X1,000X800 245X1,400X800 245X1,000X800 Colour Ivory white
Outdoor
Machine weight kg 47 37 47 37 unit Coil Type Cross fin coil
Certified Operation range °CWB 14 to 25 Compressor Type Hermetically sealed scroll type
Colour Ivory white Motor output kW 2.4 3.1 2.4 3.1 2.8 3.4 2.8 3.4
Outdoor
unit Coil Type Cross fin coil Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
Compressor Type Hermetically sealed scroll type Sound pressure Cooling dB(A) 50
Motor output kW 2.4 2.9 2.4 2.9 2.4 2.9 2.4 2.9 level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7(Charged for 30 m) Dimensions (HXWXD) mm 1,170X900X320
Sound pressure Cooling dB(A) 50 Machine weight kg 97
level4 Night quiet mode dB(A) 45 46 45 46 45 46 45 46 Certified Operation range °CDB 21 to 46
Dimensions (HXWXD) mm 1,170X900X320 Piping Liquid (Flare) mm φ9.5
Machine weight kg 97 connections Gas (Flare) mm φ15.9
Certified Operation range °CDB 21 to 46 Drain Indoor unit mm VP20 (I.D φ20XO.D φ26)
Piping Liquid (Flare) mm φ9.5 Outdoor unit mm φ26.0 (Hole)
connections Gas (Flare) mm φ15.9 Max. interunit piping length m 50 (Equivalent length 70)
Drain Indoor unit mm VP25 (I.Dφ25XO.Dφ32) Max. installation level difference m 30
Outdoor unit mm φ26.0 (Hole) Heat insulation Both liquid and gas piping
Max. interunit piping length m 50 (Equivalent length 70) Note :
Max. installation level difference m 30 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Heat insulation Both liquid and gas piping Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.

47 48
OPTIONS

Indoor unit Indoor unit


CEILING MOUNTED CASSETTE TYPE COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Kit name Kit name
Name of option Remark Name of option Remark
FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Decoration panel BYCP125K-W1 Decoration panel BYFQ60B3W1
Sealing material of air discharge outlet KDBH55K160F Remote controller Wireless type Cooling only BRC7E531W
Panel spacer KDBP55H160FA Wired type1 BRC1C61
Fresh air Chamber Without T-duct joint KDDP55B160 Navigation Remote Controller Wired type1 BRC1E62
intake kit1 type With T-duct joint KDDP55B160K Adaptor for wiring2 KRP1BA57
Direct installation type KDDP55X160 Wiring adaptor for electrical appendices2 KRP4AA53
High-efficiency filter unit (Colorimetric method 65%) KAFP556B80 KAFP556B160 Remote sensor (for indoor temperature) KRCS01-1B
(including filter chamber) (Colorimetric method 90%) KAFP557B80 KAFP557B160 Installation box for adaptor PCB KRP1BA101
Replacement (Colorimetric method 65%) KAFP552B80 KAFP552B160 Central remote controller3 DCS302CA61
high-efficiency filter (Colorimetric method 90%) KAFP553B80 KAFP553B160 Unified ON/OFF controller3 DCS301BA61
Filter chamber KDDFP55B160 Schedule timer3 DST301BA61
Replacement long-life filter KAFP551K160 intelligent Touch Controller3 DCS601C51
Ultra long-life filter unit (including filter chamber) KAFP55B160 Interface adaptor for SkyAir series DTA112BA51
Replacement ultra long-life filter KAFP55H160H Replacement long-life filter KAFQ441BA60
Branch duct chamber KDJP55B80 KDJP55B160 Fresh air intake kit Direct installation type KDDQ44XA60
Chamber connection kit2 KKSJ55KA160 Sealing material of air discharge outlet KDBH44BA60
Insulation kit for high humidity KDTP55K80 KDTP55K160 Panel spacer KDBQ44BA60A
Remote controller Wireless type Cooling only BRC7F635F Note: 1Wiring for wired remote controller to be procured locally.
Wired type3 BRC1C61 2
Installation box for adaptor PCB (KRP1BA101) is necessary.
3
Navigation Remote Controller Wired type3 BRC1E62 This optional accessory requires DTA112BA51.
Central remote controller4 DCS302CA61
Unified ON/OFF controller4 DCS301BA61
Schedule timer4 DST301BA61
intelligent Touch Controller4 DCS601C51
Adaptor for wiring5
Wiring adaptor for electrical appendices(2)5
KRP1C63
KRP4AA53 CEILING SUSPENDED TYPE
Installation box for adaptor PCB KRP1H98 Kit name
Name of option Remark
Remote sensor (for indoor temperature) KRCS01-4B FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Note: 1Refer to page 20 for the details.
Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
2
Required for installing high-efficiency filter unit and ultra long-life filter unit. Fresh air intake kit KDDQ50A140
3
Wiring for wired remote controller to be procured locally. Drain pump kit KDU50P140VE
4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. L-type piping kit (for upward direction)
5 KHFP5N160
Installation box for adaptor PCB (KRP1H98) is necessary.
Remote controller Wireless type Cooling only BRC7GA56
Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
Central remote controller DCS302CA61
Round flow type: List of optional parts required to achieve different flow patterns Unified ON/OFF controller DCS301BA61
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option Schedule timer DST301BA61
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. intelligent Touch Controller2 DCS601C51
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. Wiring adaptor for electrical appendices KRP1BA54
Wiring adaptor for electrical appendices3 KRP4AA52
Installation box for adaptor PCB KRP1D93A
All round flow 4-way flow Adaptor box mounting plate KKSAP50A56 ----------
Remote sensor (for indoor temperature) KRCS01-4B
Optional accessory parts Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life
Independently installable optional parts
Panel spacer1
remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Electrical box with earth terminal (3 blocks) KJB311AA
Electrical box with earth terminal (2 blocks) KJB212AA
Panel/grille related Panel spacer 1
o o o x o o
Note: 1Wiring for wired remote controller to be procured locally.
Operation control related Wireless remote controller o o o o o o 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Auxillary function related Fresh air intake kit (Chamber type)1,2 o o x x o o 3
Installation box for adaptor PCB(KRP1D93A) is necessary.
Fresh air intake kit (Direct installation type) o o x o o o
Insulation kit for high humidity x o x o x x
Filter related High-efficiency filter unit2 o o o o x x
Ultra-long-life filter unit2 o o o o x x
WALL MOUNTED TYPE
3-way flow 2-way flow Name of option Remark
Kit name
FAQ100CVEA
Optional accessory parts Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life Drain-up kit K-KDU572EVE
Panel spacer 1
Independently installable optional parts remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Remote controller Wireless type Cooling only BRC7EB519
Panel/grille related Panel spacer1 o3 o3 o3 x x o3 Wired type1 BRC1C61
Operation control related Wireless remote controller o3 o o o x o Navigation Remote Controller Wired type1 BRC1E62
Auxillary function related Fresh air intake kit (Chamber type)1,2 o3 o x x x o Remote sensor (for Indoor temperature) KRCS01-4B
Fresh air intake kit (Direct installation type) o3 o x o x o Central remote controller2 DCS302CA61
Unified ON/OFF controller2 DCS301BA61
Insulation kit for high humidity x o x o x x
Schedule timer2 DST301BA61
Filter related Ultra-long-life filter unit2 o3 o o o x x intelligent Touch Controller2 DCS601C51
Wiring adaptor for electrical appendices3 KRP4AA51
Installation box for adaptor PCB KRP4AA93
Branch duct connection Electrical box with earth terminal (3 blocks) KJB311AA
Optional accessory parts Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life Electrical box with earth terminal (2 blocks) KJB212AA
Panel spacer1
Independently installable optional parts remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Noise filter ( For electromagnetic interface use only) KEK26-1A
Branch duct chamber 1 1-way branch / unit 3-way flow o o o o 4 x x o Note: 1Wiring for wired remote controller to be procured locally.
(Round duct type) 2-way branch / unit 2-way flow x o o o 4 x x o 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
1-way branch / unit 2-way flow x o o o 4 x x o 3
Installation box for adaptor PCB (KRP4AA93) is necessary.
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.

49 50
OPTIONS

Indoor unit Outdoor unit


CEILING MOUNTED BUILT-IN TYPE Kit name
Kit name RZR50MVM RZR100MVM RZR100MYM
Name of option Remark Name of option
FBQ50BV1A FBQ60BV1A FBQ71BV1A RZR60MVM RZR125MVM RZR125MYM
Service panel KTBJ25K56W KTBJ25K80W RZR71MVM RZR140MVM RZR140MYM
Air discharge adaptor KDAJ25K56A KDAJ25K71A Central drain plug KKP014A4 KKPJ5G280
Remote controller Wireless type Heat pump BRC4C62 Fixture for preventing overturning ---------- KKTP5B112
Wired type1 BRC1C61 Wire fixture for preventing overturning ----------
Navigation Remote Controller Wired type1 BRC1E62 Demand adaptor ---------- KRP58M51+EKMKSA1 KRP58M51
Adaptor for wiring (interlock for fresh air intake fan) KRP1BA54
Wiring adaptor for electrical appendices KRP4AA51
Interface adaptor for SkyAir series DTA112BA51 Kit name
Central remote controller2 DCS302CA61 Name of option
RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1
Unified ON/OFF controller2 DCS301BA61 Central drain plug KKPJ5F180
Schedule timer2 DST301BA61 Fixture for preventing overturning KPT-60B160
intelligent Touch Controller2 DCS601C51 Wire fixture for preventing overturning K-KYZP15C
Note: 1Wiring for wired remote controller to be procured locally. Demand adaptor KRP58M51
2
This optional accessory requires DTA112BA51. Refrigerant branch piping kit For twin multi KHRP58P216T

Kit name
Name of option Remark
RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG
Air direction adjustment grille KPW937A4 KPW945A4
Drain plug One set includes 5 pieces for 5 units KKP937A4
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Kit name
Name of option Remark Kit name
FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE Name of option Remark
RXS50FAVMA RXS60FVMA RXS71FVMA
High-efficiency filter1 65% KAFP632B80 KAFP632B160
Air direction adjustment grille KPW945A4
90% KAFP633B80 KAFP633B160
Drain plug One set includes 5 pieces for 5 units KKP937A4 KKP945A4
Filter chamber(for rear suction)1 KDDFP63B80 KDDFP63B160
Long-life filter1 KAFP631B80 KAFP631B160
Service panel White KTBJ25K80W KTBJ25K160W
Fresh white KTBJ25K80F KTBJ25K160F
Brown KTBJ25K80T KTBJ25K160T
Air discharge adaptor KDAP25A71A KDAP25A140A
Shield plate for side plate KDBD63A160
Remote controller Wireless type Cooling only BRC4C66
Wired type2 BRC1C61
Navigation Remote Controller Wired type2 BRC1E62
Adaptor for wiring
Wiring adaptor for electrical appendices(2)
KRP1C64
KRP4AA51
Reuse of existing piping: Refrigerant pipe size table
Remote sensor KRCS01-4B
Mounting plate for adaptor PCB.3,4,5 KRP4A98 Existing pipe size (Liquid / Gas) 6.4 / 6.4 / 6.4 / 9.5 / 9.5 / 9.5 / 12.7 / 12.7 / 12.7 / Level Design pressure
Central remote controller6 DCS302CA61 Outdoor Unit 9.5 12.7 15.9 12.7 15.9 19.1 15.9 19.1 22.2 difference (High pressure)
Unified ON/OFF controller6 DCS301BA61 Condition
RZR-M 9.5 / 15.9
Schedule timer6 DST301BA61 Max.
series Max.interunit piping length ------- 10m 10m 50m 50m 50m 25m ------- ------- 4.0MPa
intelligent Touch Controller6 DCS601C51 30m
Pre-charged pipng length ------- 10m 10m 30m 30m 30m 15m ------- -------
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate.
2
Wiring for wired remote controller to be procured locally. 5
Only one mounting plate can be installed for each indoor unit.
3 6 Standard pipe size
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Same condition with standard pipe

Piping length and pre-charged piping length are shortened

Piping length and pre-charged piping length are much shortened

Cooilng capacity is lowered (pay attention to piping length)


FLOOR STANDING TYPE Reuse of existing piping is not allowed
Kit name
Name of option Remark Clean the existing piping if pre-charged piping length is exceed limit of existing piping pump down refrigerant recovery.
FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Replacement long-life filter KAFJ95L160
Remote controller Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
Central remote controller2 DCS302CA61
Unified ON/OFF controller2 DCS301BA61
Schedule timer2 DST301BA61
intelligent Touch Controller2 DCS601C51
Adaptor for wiring3 KRP1BA57
Wiring adaptor for electrical appendices KRP4AA52
Installation box for adaptor PCB KRP4AA95
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA95) is necessary.

51 52
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

[FCQ50-140KAVEA] [FCQ50-140KAVEA] [FCQ50-71KAVEA] [FCQ100-140KAVEA] [FFQ25-60BV1B]


B 585–660 (Ceiling opening space)
Connection position 300 or less 533 (Hanging bolt pitch)
860~910(Ceiling opening space) (Note 4) 81 2x100=200 85 Connection position 81 2 100=200 85 of branch duct 700
300 Note)2. 320
or less 710(Hanging bolt pitch) 950 124 of branch duct 160 (round shape type)
(round shape type) 89
9
420 8 Note 2 C/L
16-M4 Hole
C/L 16-M4 Hole 8 210
Drain connection

67
160

160
Piping Connection side

860~910(Ceiling opening space) (Note 4)


Side Ceiling

585–660 (Ceiling opening space)


533 (Hanging bolt pitch)
167
780(Hanging bolt pitch)

93
B
6

110
95
124
100

29
95
157

89
Connection position 157
Connection position

150
350 350

700
of branch duct of branch duct

950
C
(square-shaped type) (square-shaped type)
B arrow view B arrow view Piping connection 4–M4 Hole Outdoor air intake
6 side (Direct connection)
Drain Connection
Side B arrow view
7 [FCQ50-71KAVEA] [FCQ100-140KAVEA] 7
160 160 A arrow view
420 A arrow view 167 320
Connection position 124 93 67 Required space
of branch duct 109 Connection position
of branch duct 95 1500mm or more*
(square-shaped type) 95 (square-shaped type) 29
20-M4 20-M4
[FCQ50-71KAVEA] [FCQ50-71KAVEA] Prepared hole Prepared hole 1500mm or more*
3

Adjustable(0–545)
16-M4 Prepared hole 62.5 575 62.5

2 100=200 80
2x100=200 80
Adjustable(0~675)

55 840 55 Connection position 3 27-M4 Prepared hole 1500mm or more*


of branch duct

160
62.5 575 62.5

124
340 55 840 55
80 2 100=200 80 (square-shaped type)

25
196 1500mm or more*

25
81 2x100=200 85

750
5

157
350
157
350
124 64 C/L C/L
850

124
110
95

50

124
110
5
105

60

295 or more
95

213
213
*When the discharge grill is closeout, the
required space is 200mm or more.
124

80
256

260
80

285
ø1

(180)
ø1
160
246

175

160
150

Connection position

205
(kn 00
10

29

183
Connection position (kn 00

145
25
130
42
125
165

of branch duct

90
90
of branch duct ock
35 or less (round shape type) hole (round shape type) holock
20 C/L 256 35 or less 90 ) 90 e)

From the floor side 2500 or more


(required space)
50
40

(Note 4)

For height installation


157 (Note 4) Connection position

1500 or more
157 Connection position 172 45 or less 45 or less

(Required space)
183 196

For height installation


of fresh air intake kit

1500 or more
55
30

From the floor side


Hanging bolt 350 Connection position 350 Connection position of fresh air intake kit 2

2500 or more
4 1 2 of branch duct of branch duct C arrow view (direct installation type) C arrow view 211 4 Note)4.
4-M8~M10 280
(round shape type) A (square-shaped type)
(direct installation type) Hanging bolt 1
Connection position 330
of branch duct 4–M8 to M10 A
(round shape type)

1 Liquid pipe connection


[FCQ100-140KAVEA] [FCQ100-140KAVEA] Notes:
1 2 Gas pipe connection
Sticking location for manufacture's label
manufacture's label for indoor unit : on the bell mouth inside suction grille 3 Drain pipe connection
16-M4 Prepared hole
3 55 4 Power supply connection
Adjustable(0~675)

55 840 55 Connection position 840 55 manufacture's label for decoration panel : on the inner frame inside suction grille
of branch duct 2 100=200 27-M4 Prepared hole 2
In case of using wireless remote controller, this position will be a signal receiver.
340 81 85 Required space 1500mm or more 5 Remote control code and
(square-shaped type) 64 160 refer to the drawing of wireless remote controller in detail. control wiring connection
80 2 100=200 80 5 200mm or more
850

3
167

160 50 1500mm When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit 6 Air discharge grille
95

167
95

or more
93

continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
105

1500mm
60

7 Suction grille
29

or more 4
Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45mm or less between
160
298

200mm the main unit and the ceiling opening so that the panel overlap allowance can be ensured. 8 Drain hose
or more 1500mm or more
175
160
288

160
150
29
10

130
42
125
165

67

The necessary space is 500mm or more when the


20 C/L 35 or less 256 35 or less air-outlet is blocked with the accessory.
From the floor side 2500 or more
(required space)
50
40

CEILING SUSPENDED TYPE


For height installation

157 Moreover when the corner areas are blocked


1500 or more

(Note 4) 157 (Note 4)


Hanging bolt 350 Connection position Connection position (both right and left of the blocked air outlet),
4 1 2 350 the necessary space is 200mm or more.
4-M8~M10 280 of branch duct of branch duct
Connection position (round shape type) A (square-shaped type)
of branch duct 330
210
(round shape type) [FHQ50/60DAVMA] 156
Connection position of fresh air intake kit
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90

35

157 63
Notes:

92
175
87
163
30

100

90
189
1

115
Sticking location for manufacture's label

210

195
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface 1 Liquid pipe connection

40
63

bolt pitch)
(Hanging
manufacture's label for decoration panel : 2 Gas pipe connection 116 51 60 134 59
12

260
Decoration panel's corner decoration cover inner surface
2 3 Drain pipe connection 10 Position slit hole for taking out in pipe back
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail. 4 Transmission wiring connection (View from the front)

(Required space)
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit 5 Remote controller wiring 8

(Required space)
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. connection
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 6 Air-outlet 220
920 103
between the indoor unit and the ceiling opening so that 7 Suction grille 19 15
690 (Hanging bolt pitch)
the panel overlap allowance can be ensured. 8 Corner decoration cover

5
5
Please do not place the thing been damp and troubled under an indoor unit.
9 Drain hose (accessory) Hanging bolt
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

5
4 11

175
4-M8~M10 1 5

197

91
131
197
235
Position : Hole of wall for taking out in pipe back

From the floor side 2500 or more

(Required space)
(View from the front)

For height installation

300 or more
13 57
57 6 14
30 or more 960 30 or more φ 45
(Service space) (Service space)
Obstacle
The Front
Floor side Brand name plate
(Note.2) 1 Air discharge grille
2 Air suction grille
3 Air filter
Drain piping connection VP20 4 Gas pipe connection
(For left pipe) 6
5 Liquid pipe connection
6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger

268

268
221
214
9 Rear pipe penetration cover
10 Top panel penetration cover
76 83 11 Right side pipe connection
3 2 7 5 105 4
12 Left back drain pipe connection
156
13 Left side drain pipe connection
Notes: 14 Right side drain pipe connection
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 15 Hole of wall for taking out in pipe back
2
In case of using wireless remote controller, this position will be a signal receiver. 16 Upward drain pipe connection
Refer to the drawing of wireless remote controller in detail. 17 Upward gas pipe connection
3
Please do not place the thing been damp and troubled under an indoor unit. 18 Upward liquid pipe connection
When the case where humidity is 80% or more, and the drain outlet are choked up 19 Power supply wiring and a unit wiring back connection
and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

53 54
DIMENSIONS (Unit: mm)

CEILING SUSPENDED TYPE WALL MOUNTED TYPE

[FHQ71DAVMA] [FAQ100CVEA]
210 Connection position of fresh air intake kit
156
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90 Piping direction

35

157 63
92

(Required space)
175
87
30

163
189
100
210

115
90
195
Approx.440

50 or more
40
63 242

bolt pitch)
(Hanging
116 51 60 134 59

260
12
10 240
Position slit hole for taking out in pipe back

(Required space)
(View from the front) 7
8
(Required space)

220
103
1230 19 15

(Required space)
690 (Hanging bolt pitch)

340
5
Dimensions for

30 or more
Hanging bolt 4 5 11

175
full open
5

4-M8~M10 1 front panel

91
131
197

197
Position : Hole of wall for taking out in pipe back
235

(View from the front) 3


(Required space)
From the floor side 2500 or more

57
6
For height installation

300 or more

13 14 9 1 Piping direction 1200 Name plate Note)2 Piping direction 50 or more


2500 or more 120 or less
57 2 50 or more
φ45 For installation
30 or more 1270 30 or more (Requred space) (Requred space) in high spaces
(Service space) (Service space)
The Front 1 Air discharge grille 79.5 1085 35.5

14.5
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter φ80 hole
4 Gas pipe connection Outside line
Drain piping connection VP20 5 Liquid pipe connection Piping and
6 6 Drain pipe connection φ80 hole Wiring intake
(For left pipe)
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268
268

221
214

114
10 Top panel penetration cover

45

45
11 Right side pipe connection
76 83 12 Left back drain pipe connection
3 2 7 5 105 4 65 6 Approx.400 89 1 Front panel
13 Left side drain pipe connection
156 14 Right side drain pipe connection 2 Front grill
5 Approx.460
15 Hole of wall for taking out in pipe back 3 Air outlet
Notes: Mounting location Approx.465
1 16 Upward drain pipe connection 4 4 Gas pipe
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2 17 Upward gas pipe connection Notes: 5 Liquid pipe
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail. 18 Upward liquid pipe connection 1
Location of unit's of Name Plate:Right side surface of casing 6 Drain hose
3
Please do not place the thing been damp and troubled under an indoor unit. 19 Power supply wiring and a unit wiring back connection 2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 7 Earth terminal
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection 3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, 8 Right side pipe connection hole
and the drain outlet are choked up and the air filter are dirty, dew may fall. 9 Left side pipe connection hole

CEILING SUSPENDED TYPE CEILING MOUNTED BUILT-IN TYPE

[FHQ100-140DAVMA] [FBQ50/60/71BV1A] 7 145 630


210 (Suspension position)
8
156 Connection position of fresh air intake kit
105 120
18 17 20 16 102 φ100(Knock out hole)
9
131 57 90
35

157 63
92

B
87
30

163
189
100

90
210

175

115
195

(Suspension position)
40

63

160
bolt pitch)
(Hanging

116 51 60

250
208
150
134 59
260

228
12

H
10
Position slit hole for taking out in pipe back

J
I
(Required space)

(View from the front)


8 27
220 C
(Required space)

103
1550 19 15
(Hanging bolt pitch) A view 160 P.C.D. 600
690
5

Hanging bolt 125


Fresh sir intake position
4-M8~M10 1 4 5 11 (Knock hole)
175
5

9
91

10
131
197

100
197
235

Position : Hole of wall for taking out in pipe back


(View from the front) 25 800 25
From the floor side 2500 or more

(Required space)

57 D 60 6-M5 Hole
For height installation

14
300 or more

13 6 440
57 30 or more 1590 30 or more E 50 (Circumference)
(Service (Service φ45 Suspension bolt
315 3 5
65 B view
space)
The Front
space) 1
1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille

67

135 120
2 65=130
150
(Note.2)

195
Floor side

200
135
3 Air filter
300
245
215
150
B A
4 Gas pipe connection
5 Liquid pipe connection
1 Liquid pipe connection
Drain piping connection VP20
6 2 Gas pipe connection

3 65=195
(For left pipe) 6 Drain pipe connection
2
Service space

7 Earth terminal (inside the control box) (M4) 57 3 Drain pipe connection
F
Note)2

6 4
300

8 Hanger Service space 4 Interunit wiring port


G 300 or more 45 46
9 Rear pipe penetration cover 5 Power wiring port
268

268

6 Drain hole
221
214

10 Top panel penetration cover


11 Right side pipe connection 7 Discharge flange
76 83 12 Left back drain pipe connection 8 suction flange
3 2 7 5 105 4
13 Left side drain pipe connection 9 Switch box
156 14 Right side drain pipe connection 10 Inspection hole
Notes: 15 Hole of wall for taking out in pipe back Notes:
1
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 16 Upward drain pipe connection Location of unit's Name Plate: Fan hosing surface.
2 17 Upward gas pipe connection
2
If the ceiling is not removable, a 300 mm service space A B C D E F G H I J
In case of using wireless remote controller, this position will be a signal receiver.
18 Upward liquid pipe connection must be kept between the unit and the ceiling. FBQ50BV1A4 556 533 4X120=480 700 460 3X150=450 485 6X65=390 7X65=455 750
Refer to the drawing of wireless remote controller in detail. 3
3
Please do not place the thing been damp and troubled under an indoor unit. 19 Power supply wiring and a unit wiring back connection Mount the air filter at the suction side.
(Select its colorimethod (Gravity method) 50 % or more) FBQ60/71BV1A4 856 833 6X120=720 1000 760 5X150=750 785 11X65=715 12X65=780 1050
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

55 56
DIMENSIONS (Unit: mm)

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FLOOR STANDING TYPE

[FBQ50-71EVE] [FVQ50-60CVE, 71-140CVEB] 260


Inspection hatch 2 4- 14 Hole 130 215 This model to be fixed with fixture
30-φ4.7hole 134 630 10 450 or more CASE1) Control box (For bolt) 126 as shown below.
(All around) (Hanging bolt position) Inspection hatch 1 Suction grille
( Drain

300 or more
pan removal stopper
and part exchange. )
(450x450)

M
Inspection hatch 3 In case of fixing it at the bottom
7

200 or less
8 ※When can work enters (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE) In case vibration resistance is

P
the space under the unit,
required, fix it at both the bottom

N
inspection hatch 2 is Control box

130
unnecessary. and the rear.
Control box
0.7
9 Inspection hatch Fig.A
Ceiling

1300 or more
11x65=715
1038(Hanging bolt position)

CASE 2),3) Detail View

1000 or more
Control box
50
835

Inspection hatch1 (Two both sides) or

30
(450x450) 600 68 D 330 mo

18
or less
20 or more
Air Air inlet re 50

200
outlet Control box
Pull out or
13x65=845 800 or more 800 or more mo
1000
36-φ4.7hole Inspection hatch 2 re
500
Inspection hatch View B-1 View B-2 direction

500

(All around) (SAME AS THE INDOOR
Ceiling UNIT SIZE OR MORE)
Unit base of air-filter
Fixture

314
Air inlet (Accessory) 2-7X15 re
mo
Air outlet
oblong hole
0 or
(For wood screw) 50

(Pull out dimension of air-filter)


Suspention 1
200 or less

Inspection hatch 2※ Required space


450 16-8x12 oblonghole (4pieces) bolt Fig. A-1
(450X450)
53
(Service space)

65
69

(All around)
450 or more

740 or more
13
176
100
194

677
Notes:
Drain pan 5x156=780 26 1 Suction grille
138

maintenance space 1
Locations of Manufacturer's Label:Surface of a control box
792 8 2 Air filter
Control Box
2
Make sure to mount the air filter inside the air passage on
Inspection hatch 1 815
maintenance space the suction side. (Select Duct Collection Efficiency 1 3 Through hole for side piping

1850
450 or more 800 or more
View <Gravimetric Method>50% or more.) 9
(Service space) (70x90 oblong slit hole)
(From the Air outlet) 3
If the temperature and humidity in the ceiling is likely to Approx.46
12 exceed 30℃ and RH80%, strengthen heat insulation by 4 Through hole for side piping
10 Full open
3x50=150

( 80 slit hole)
(643 or less)

1 2 6 5 3
300 or less 499 applying the additional insulation materials such as glass
2x50=100

position of
207 Adjustable

wool or polyethylene that has thickness of 10mm or more. suction grille 3 5 Through hole for side piping
850 or less

4
Do not put things that should not get wet under the indoor unit. G 6 ( 27 slit hole)
Dews may drop when humidity reaches over 80%, a drain E

825
5 6 6 Through hole for rear
245

gets stuck or air filters are not clean. F

222
Air Air inlet
6
183

208
136

226
123

(Note.2)
outlet 5
Space for Service Works piping/wiring

616
541
6x150=900
4 (80x130 oblong slit hole)
60

91 Provide service spaces for service work such as check and

95
38

4 7

50
952
300 or more

(A case without

179 50 maintenance of the control box and drain pump by one of the 7 Through hole for bottom
2500 or more

11

50
(Note.5)

977 following ways.


the ceiling)

300
piping/wiring

100
100
18-8x12 oblong hole (From the Air inlet) 1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of

95
Drain pan maintenance 800
check hole (All around) 300mm or more under the unit. (Fig.A) A H
(126x130 square hole)
200 184 184
Note:Inspection hatch 2 is not needed when there is a space for B 8 Liquid pipe connection

75
Ceiling Floor surface 223 J

34
service work under the unit. C 9 Gas pipe connection
253 K
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance) Inspection hatch 2 under the unit. (View B-1) 598 L 10 Drain pipe connection
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory) A B C D E F G H J K L M N P
Provide enough space for maintenance and mount the drain
4 Earth terminal(terminal in Control box) 9 Air suction flange pan and control box. Notes: FVQ50/60CVE, 71CVEB 50 110 186 270 45 50 50 110 180 186 242 57 144 149
5 Control box(Inside) 10 Hanger Check the drawing of optional accessories when mounting 1
Sticking location for manufacturer’s label: on the surface of
optional accessories such as filter chamber and humidifier.
cover of switch box inside the suction grille. FVQ100/125/140CVEB 130 190 266 350 44 49 130 190 260 266 322 79 202 229

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

[FBQ100-140EVE]
44-φ4.7hole 134 630 10
(All around) (Hanging bolt position) 50-φ4.7hole
(All around) CASE1) Control box
8
9
300 or more

Inspection hatch 1
(450x450) Inspection hatch 3
200 or less

Inspection hatch 2
450 or more (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
( Drain
and part exchange. )
pan removal Control box
Inspection hatch
1438(Hanging bolt position)

Control box Fig.A Ceiling


1700 or more
18x65=1170

※When can work enters


the space under the unit, CASE 2),3) Control box
20x65=1300

1400 or more
1235

inspection hatch 2 is Inspection hatch1


200 or less

unnecessary.
1400

(450x450)
20 or more

Control box
Air inlet 800 or more 800 or more
Air B Inspection hatch 2
Inspection hatch View B-2
500

outlet View B-1


Ceiling (SAME AS THE INDOOR
UNIT SIZE OR MORE)
Air inlet
500

Air outlet
Unit base

650 20-8x12 oblonghole bolt Inspection hatch 2※


Suspention
(All around) (4pieces) (450X450)
200 or less

Fig. A-1
(Service space)
450 or more

53
65
69

176
100
194

13 Notes:
Control Box 26
1
Locations of Manufacturer's Label:Surface of a control box
maintenance space 7x156=1092 2
Make sure to mount the air filter inside the air passage on
138

Drain pan 1192


maintenance space the suction side. (Select Duct Collection Efficiency
1215 <Gravimetric Method>50% or more.)
Inspection hatch 1
450 or more 800 or more View 3
If the temperature and humidity in the ceiling is likely to
(Service space) (From the Air outlet) exceed 30℃ and RH80%, strengthen heat insulation by
12 applying the additional insulation materials such as glass
3x50=150

300 or less
(643 or less)

699 wool or polyethylene that has thickness of 10mm or more.


2x50=100

2
207 Adjustable

1 6 5
850 or less

3 4
Do not put things that should not get wet under the indoor unit.
Dews may drop when humidity reaches over 80%, a drain
gets stuck or air filters are not clean.
226
208
245

Air inlet
60

222

Space for Service Works


183

Air 5
(Note.2)
136

123

outlet
91 Provide service spaces for service work such as check and
26-8x12 oblong hole
38

300 or more

4 7
(A case without

maintenance of the control box and drain pump by one of the


2500 or more

100 100 6x150=900 100 100


50
(Note.5)

11 179 (All around) following ways.


the ceiling)

300 1352
Drain pan maintenance 800 1377 1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of
check hole (From the Air inlet) 300mm or more under the unit. (Fig.A)
Ceiling Floor surface Note:Inspection hatch 2 is not needed when there is a space for
service work under the unit.
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance)
Inspection hatch 2 under the unit. (View B-1)
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory)
Provide enough space for maintenance and mount the drain
4 Earth terminal(terminal in Control box) 9 Air suction flange pan and control box.
5 Control box(Inside) 10 Hanger Check the drawing of optional accessories when mounting
optional accessories such as filter chamber and humidifier.

57 58
DIMENSIONS (Unit: mm)

OUTDOOR UNIT // RKS25/35AVMG OUTDOOR UNIT // RXS71FVMA

4 - Holes for anchor bolts 900


Drain outlet 4–cuts for anchor bolts
(M8 or M10) 620 140
(I.D φ15.9 hose for connection) (M12)
574 105.5
13 490

117 102 71

(345-355)
320
350

380
29.5
311

45 376 191

30
30
Drain outlet
(I. D o/ 25 hose for connection) Gas stop valve
Handle Terminal strip Outdoor air
Brand name label Name plate with earth terminal thermistor
285 8 12 765 63 Liquid stop valve
Outdoor air thermistor

Manufacture's Liquid
Label stop valve
( 6.4CuT)
Wiring
inlet
550

770
Service

410
port

165
105

126
Gas pipe

90
196 22

50
Indication label (o/ 15.9 single union)
In case of removing 78 104 30
stop valve cover Interconnecting piping
108 and wiring inlet 67 Liquid pipe
Gas stop valve (o/ 6.4 single union)
( 9.5CuT)
Wall height on air outlet side Wall height on air outlet side
Minimum space for air passage Minimum space for air passage
=less than 1200 =less than 1200
150

100
100
100

350
50
150
100

350
50 50

350
50 50
50 50
300

100

OUTDOOR UNIT // RKS50/60AVMG, RXS50FAVMA, RXS60FVMA OUTDOOR UNIT // RZR50/60/71MVM


825 78 Drain outlet
325 I.D. 18 hose for connection
124 580
2 845 78
36

300
Drain outlet
(I.D. o/ 15.9 hose for connection) 131 573.5
350

330

300

4 –Holes for anchor bolts


(M8 or M10)

342
326

300
In case of removing
stop valve cover
10

25

Name plate Outdoor air temperature thermistor


Brand name label Wiring inlet
Terminal strip with earth terminal

20
7
Hole for anchor bolts Name plate
(M8 or M10) Earth terminal
Wiring inlet in switch box
735

595

60
89 64

105
Liquid 155 18 Service port 144 20
stop valve 160 30
(o/ 6.4CuT) Liquid stop valve

112
Gas stop valve (o/ 12.7 CuT) ( 9.5CuT)

163
Service port

272
269
Wall height on air outlet side Service port
Minimum space for air passage
=less than 1200
Gas stop valve
100

Drain outlet ( 15.9CuT)


21
94 Drain outlet
200
100
350
100

299
419
50 50 449
479
50
350

509
559
350

59 60
DIMENSIONS (Unit: mm)

OUTDOOR UNIT // RZR100/125/140MVM / MYM REMOTE CONTROLLER


Hole for anchor
bolt 4-M12
Wireless type

30
(345∼355)
• Remote controller dimensions CEILING MOUNTED CASSETTE TYPE <Round Flow> COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

350

320
Transmitting part • Receiver installation procedure • Receiver installation procedure

55
37
Drain piping Refrigerant piping
side side
Receiver
38 Refrigerant

30
piping side
91

157
160 620 160 Receiver
30 940 3

Drain piping
62 17.5 side

4 •Remote controller holder


7 installation procedure Decoration panel
2 <installation to wall surface> • Receiver detail
6 • Receiver detail Decoration panel
1
990

7 5 Liquid crystal
(BYFQ60BW1)
5 6 remote controller
(BYFQ60B7W1)
(BYFQ60B8W1)
(wireless)
5

55
Remote controller
60

55
holder

340
339

223
95
95

95

84
53

53
89 19

53
CEILING MOUNTED BUILT-IN TYPE
89

19 80 52 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
7 6 142
• Receiver installation procedure • Receiver installation procedure
145 13 67 • Receiver detail
8 90 16 2-5x9 Slot The Front Receiver Receiver
16
161
260

1 Gas pipe connection


68

(Ceiling opening)
285
279

83.5
2 Liquid pipe connection

120

106
72
5 3 Service port
36 • Receiver
4 Earth terminal detail
61
262 5 Refrigerant piping intake
0.5
416 6 Power supply wiring intake 70 18 35 49
595 7 Transmission wiring intake
(Ceiling opening) • Receiver
Switch box detail
8 Drain pipe connection (field Supplied parts)

Service space for ceiling installation


Note :

(Srevice space)
More than 90
Do not install more than 3 receivers in
OUTDOOR UNIT // RZR125/140LVVM, RZR125/140LUY1 the vicinity of one another.
With 4 or more units, there is always
the possibility of malfunction

Hole for anchor


bolt 4-M12
Wired type
30

• Remote controller dimensions

BRC1C61 • Installation method


(345~355)
350

A Exposed body, exposed cord B Exposed body, embedded cord C Exposed body, embedded code
320
61

Conduit
43

17
Staple
Remote Remote
controller controller
Remote

42
controller
41

120
30

84
94

117
38
0~5
140 620 140
(Between remote 17 Through hole
controller and
30 900 120 17 18 control box)
( 12- 16)
4 Cord
17
outlet Control box
23 28
3 hole
Specifications of cord
46 Note)
2 Type Shield wire (insulated thickness: 1 mm or more) 1. Remote controller cord and staple are not
Size 0.75~1.25 mm 2 attached.
1 They are field supplied parts.
Total length 500 m
7
7
6 BRC1E62 • Installation method
1170

Upper case Lower case


7 6 A Exposed cord B Embedded cord C Embedded cord Condit
5 Top left Top center
Staple
19 (use switch box) 19
6 5 outlet outlet

42
Operation
5
55

lamp
120

84
(Green)

40
423
422

84
84
55

40
223

Code outlet hole


95

95
95

120 19 28 5X15 oblong hole Note)2 28


84

48.5 46
5X7 oblong hole 23 48.5 Through hole 0~5
Left outlet ( 8- 10) Switch box for one switch Switch box for two switch (Between remote
89

54
60

46 19
54

53

Lower case portion ex.) KJB111A ex.) KJB211A controller and


89 19 19 80 52 (optional accessory) (optional accessory) control box)
Switch box
Lower case portion [field supplied part]
142 145 13 67
Note)
1. Remote controller cord and staple are not attached. They are field 2.If the hole size is too large or the location
8 71 16
supplied parts. is not proper, the hole may come out from
16

Specifications of cord the remote controller.


1 Gas pipe connection
2 Liquid pipe connection Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
70 102 117

3 Service port Size 0.75~1.25 mm2


58

4 Earth terminal
Total length 500 m
5 5 Refrigerant piping intake
6 Power supply wiring intake
45 376 191 7 Transmission wiring intake
8 Drain outlet

61 62
Installation service space for outdoor unit (Unit: mm)

For RZR50-140MVM, RZR100-140MYM


1.RZR50/60/71MVM 2.RZR100-140MVM, RZR100-140MYM
MEMO
1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side

1) When the overhead space is open 1) When the overhead space is open
1 2
1. For single unit installation 1. For single
When there is an 1 2
unit installation
obstruction only
on the inlet side 0 mo
re
50 ore 0 or
or
m 50
re
mo 0 2. For multiple units installation (more than two units)
or 10 ore
50 m 10
or 0
mo or
When there are obstructions on 1 2 re 10
0
mo or
both sides re

1 2
25
0o
rm
ore
10 10 re
0o
rm 0o mo ore
ore rm or rm
re ore 00 0o
25 mo 10 10 10
0
0o r 0
rm 0o
0o
rm 10 ore
ore 10 ore or
m
2) When there is an obstruction in the overhead space
1. For single unit installation
2. For multiple units installation An obstruction
s
(more than two units) ss in the overhead les
10 o r le or
0 00 space 0
mo or 5 50

1000 or more
When there are re 10

1000 or more
0
mo or 1 2
re
obstructions on
both sides 10
00
or
mo
re

re
20 mo
0o
rm 0 or
ore 30 re re
mo mo
0 or or
50 0
50

2. For multiple units installation (more than two units)


ss
2) When there is an obstruction in the overhead space 0o
r le
ss
0o
r le
50 50
1 2

1000 or more
1. For single unit installation
1000 or more

10
0
mo or
re
When there is an obstruction on the inlet side
ss
r le
1000 or more

1 s 2 0o
r les 50 10
0o
or more

0
50 mo or
1000

re
25
An obstruction 0o
rm
in the overhead ore
An obstruction re
space ore in the overhead mo
o rm or
00 space 00
10 10
ore
rm 0
0o 10 ore
10 m
or
3 When there are obstructions on both
When there are obstructions on the inlet side and
both lateral sides
the inlet and outlet sides
An obstruction
in the overhead ss
(When the obstruction on the outlet side is higher than the
1000 or more

s
les r le
or 0o unit itself)
1000 or more

0 space 50
50
1 2
1) When the overhead space is open
(There is no limit to the height of the obstruction on the
outlet side.)
or 150 or 150
mo mo
re ore re 1. For single unit
rm or 150
0
15 ore 1 2
or 250 0o
mo
re
15 mo
re or
m
installation
H
L

2. For series installation (more than two units)


50 ore 0
10 ore
When there are obstructions on the inlet side and 0 or
m
or
m
0
both lateral sides 50 ore
m L H 50 ore
m
An obstruction or or
in the overhead
1 space 2 2. For series installation (more than two units)
1000 or more

s 10 ss
les 0 r le 10
mo or 0o 0
1000 or more

0o
r
re 50 1 2 mo or
50 re 10
0
mo or
re
10
0o
rm
L

1 1 ore
or 000 or 000
mo mo 25
re re 0o
or 250 rm
ore 0 0
mo ore 20 ore 30 ore
re rm m
0
20 ore 0o or or
m
or 250 m
2
or 00 30 00 00
mo or mo 10 ore 10 ore
re re or
m L H or
m

Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
63 64
MEMO

65 66

Potrebbero piacerti anche