Polyurethane, waterproofing and protective traffic-deck coating system

Description Primary uses


Mastertop®1332 is a UV stable polyurethane based • Car park decks (exposed and intermediate)
multi-component car park decking system for • Ramps
exposed and intermediate traffic decks where crack • Heavy duty turning areas
bridging and waterproofing properties are required.

Packaging
Mastertop®1332 has been tested for crack bridging in
Mastertop®Primer2 12.4kg
accordance with ASTM C836.
Mastertop®SRA No3 25kg
• Mastertop®Primer2 - Is a high grade, low- Mastertop®Membrane23 30kg
viscosity, two-component epoxy resin primer and Mastertop®TC458 35kg
substrate sealer. Mastertop®TC44 LM 18 litres

• Mastertop®SRA No3 - A graded, high purity


quartz aggregate with a particle size in the range Coverage
0.3–0.9mm. Used as a multi action mechanical Mastertop®Primer 2 0.15-0.30kg/m² depending on
surface texture and porosity.
key, wear enhancer and to provide skid Mastertop®SRA No3 Total coverage from 1.6kg/m²
resistance, it’s use is the means by which Mastertop®Membrane 23 from 0.5kg/m²
thickness is attained with economy for the Mastertop®TC 458 0.8-1.2kg/m² (anti-slip) in 2-3
coats
various wearing conditions such as: in traffic
lanes, ramps and turning areas.
Typical properties∗
• Mastertop®Membrane23 – is a two component Mastertop®Primer 2
solvent-free polyurethane membrane suitable for Cured at 7 days @20°C
use in trafficked coating systems that require Pot Life: 25°C 20 mins
crack bridging capability. When used in car park Density: 1.09
Bonding strength Greater than cohesive strength of
decking systems it will bridge dynamic cracks. typical good quality concrete
• Mastertop®TC458 - Is a single component Application time approx. 20 mins. at approx. 25°C
polyurethane coating designed for application as Application temperature 10°C to 40°C substrate temp
a topcoat on traffic deck systems. It provides a Recoatable after approx. 6 hours at 30°C
approx. 12 hours at 20°C
UV-resistant, hard-elastic surface resistant to
approx. 24 hours at 10°C
general and vehicle related chemical spillage and
abrasion. Mastertop®Membrane23 – Physical properties
• Mastertop®TC44LM – A tough, surface applied Mix ratio A:B 4:1 by weight
pigmented line marking coating. Mixed density 1.18gm/cm³
Pot Life at 20°C - 30kg unit 45 minutes
Tensile strength DIN 53504 6N/mm²
Elongation at break DIN 53504 100%
Shore A Hardness Approx. 80
Mastertop®1332
Mastertop®TC458 - Typical properties
Weak or damaged concrete must be removed, and
Mixed density 1.30-1.40gm/cm³ depending on
colour replaced with a suitable repair compound from the
Curing at 20°C and 60% rel. Capable of bearing loads at 48 Emaco or Concresive range of products. Surface
atm. hum. hours
defects should be repaired using Concresive 2200 or
tack free approx. 30 mins.
to be walked on approx. 2 hours other suitable repair compounds from the Concresive
Reaction temperatures from +5°C to +40°C or Emaco range.
Rel. atm. humidity 40-90%
Tensile strength DIN 53504 approx. 4.5N/mm²
Priming
Breaking elongation DIN approx. 200%
53504 Mix and apply Mastertop®Primer2 surface
Water vapour diffusion approx. 3000 conditioner to the prepared, dust-free surface at
resistance factor DIN 52615
approximately 0.15-0.30kg/m². Into the wet primer,
Fire classification Swiss Fire Class, Fume Class 1
Resistant to flying fire and heat scatter 0.6kg/m² Mastertop®SRA No3.
radiation in accordance with
DIN 4102-B2
Slip resistance BS 7976-2 : Mixing and application
2002 TRL 96 Mixing for Mastertop Membrane 23:
4S 66 Mix the A and B components of the

Properties listed are only for guidance and are not a Mastertop®Membrane23 together using a slow speed
guarantee of performance
(400 rpm) drill with a spiral mixing head. Work the
mixer round the mixing pail to ensure it scrapes the
Standards
side and bottom of the pail. Pour mixed material into
Complies to ASTM C957 : 1993 when tested in
a clean pail and mix for a further 30 seconds
accordance with:
ASTM C501 : 1990
Pour the mixed material onto the floor and spread at
ASTM C794 : 1993
the required coverage (minimum 0.5kg/m²) using pin
screed or trowel. Into the wet
Guide to application
Mastertop®Membrane23, broadcast aggregate
Application temperature:
Mastertop®SRA No3 to excess (from 1.0kg/m²).
The quality of the final coating is dependent on the
Allow to cure for 24 hours at 25°C. Remove excess
substrate and the material temperatures; we
aggregate by sweeping or vacuuming.
recommend a substrate temperature of min. +12°C
and max. +35°C.
Topcoat
Apply Mastertop®TC458 at a minimum of 0.4kg/m²
Surface preparation and priming
per coat (two coats minimum).
The surface to be coated must be clean, dry, free of
laitance, oil, grease or any substance that may
Chemical resistance
impair adhesion. The preferred methods of surface
Contact the BASF Construction Chemicals SA
preparation are captive blasting, surface grinding or
Technical Department
similar.
Mastertop®1332
Storage Note
Store under cover, out of direct sunlight and protect Field service, where provided, does not constitute
from extremes of temperatures. supervisory responsibility. For additional information
contact your local BASF Construction Chemicals SA
Failure to comply with the recommended storage representative. BASF Construction Chemicals SA.
conditions may result in premature deterioration of reserves the right to have the true cause of any
the product or packaging. For specific storage difficulty determined by accepted test methods
advice consult BASF Construction Chemicals SA’s
Technical Services Department. Quality and care
All products originating from BASF Construction
Chemicals’ SA facility are manufactured under a
Safety precautions
management system independently certified to
As with all chemical products, care should be taken
conform to the requirements of the quality,
during use and storage to avoid contact with eyes
environmental and occupational health & safety
mouth, skin and foodstuffs (which can also be
standards ISO 9001:2000.
tainted with vapour until product is fully cured or
dried). Treat splashes to eyes and skin
immediately. If accidentally ingested, seek
immediate medical attention. Keep away from
children and animals. Reseal containers after use.

Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is given or
implied with any recommendations made by us, our representatives or distributors, as the conditions of use and the competence of any
labour involved in the application are beyond our control.
As all BASF’s technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.
BASF Construction Chemicals South Africa (Pty) Ltd
P.O. Box 420, Westonaria, 1780 852 Sixteenth Road, Midrand
11 Pullinger Street, Westonaria, 1779 PO Box 2801, Halfway House, 1685
Tel: +27 11 203 2405
Tel: +27 11 754 1343
Fax: +27 11 754 1105 Website : basf-cc.co.za