# Site Information IRAQ_WIRELESS HARDWARE ACCEPTANCE CHECK LIST_V1

Comments
1 SITE A ID
2 SITE B ID
Back
3 LINK TYPE :
Edge ✘ Termi
4 SITE A NAME
bone
5 SITE B NAME nal
6 Site topology (GF/RT) site
7 Site Type (ID/OD)
8 Site category
9 Region
10 Area
11 Company
12 Inspection Date Conditio
13 Vendor Representative : Conditio
14 BeeCable Inspection : nally Reject
Task Description Accept nally Reject
#
accepte ed Status Comments
1
ed
Cabinet has no external or internal damage
accepte ed i
2 Cabinet is sealed and weatherd proof i
3 d
Cabinet is fixed and bolted to concert foundation by 4 screws j i
4 Cabinet door can open without obstacle j i
5 Cabinet without internal Alarms j i
6 Cabinet without External alarms j ir
7 Cabinet Bulbar connect with Main Busbar with labels j ir
8 check Door coolant system j ir
9 All boards are plugged in correctly and secured. Racks configuration is according to site configuration . j ir
10 cabinet configuration is verified with configuration data sheet. j ir
11 All Cables entered in correct hole j ir
12 No scratches and damage in the Batteries (for new Batteries only ) j ir
13 Batteries Properly installed (write number of battery set and capacity ) , battery test j ir
14 Batteries pip & Sensor & cover installed j ir
15 Batteries cables systemized with labeled both ends with shrink j ir
16 internal Alarm cabling is wired and labeled correctly in both sides j ir
17 All external alarms connected to the SLPU, labeled and Systemized j ir
18 BBU grounded j ir
j ir
j
19 BBU Main and Standby Power connected to 06 port in DCDU1 and DCDU2 with labels and Systemization
20 BBU fixed by 4 screws
j ir
21 All Fibers connected with BBU with Good Systemization & Labels ir
22 DCDU grounded j ir
23 DCDU cables systemized with labels bootless and shrink j ir
24 DCDU fixed by 4 screws j ir
25 All RRU cables connected with DCDU with Good Systemization & Labels & shrink j ir
26 All Cables in the Rectifier with Bootless j ir
27 All Cables in the Rectifier installed in the CB of LLVD & BLVD according to Huawei Design j ir
j ir
j
28 AC cable with bootless at both ends (Rectifier & MDB)
ir
j
29 GPS installed properly
ir
j
30 GPS Arrester grounded
ir
j
31 GPS Cable covered by shielded flexible PIP
ir
j
32 GPS Cable weatherproofed
ir
j
33 DC Cables & Fiber Systemized from the cabinet till base of tower without cross
ir
j
34 DC Cables Systemized in the tower without cross by clamps each 1.5m
ir
j
35 DC Cable Grounded from RRU Side
ir
j
36 RRU Installation according to Huawei Standard
ir
37 RRU DC power cable grounded by earth kit
j ir
38 RRU Grounding & Labeled from RRU Side & BusBar
j ir
39 Fiber Loop inside tray box with color Labels not less than 3m loop
j ir
40 Tray and loop Box installed properly
j ir
41 RET is connected and waterproofed
j ir
42 RET is fixed and labeled
j ir
43 Optical cables systemization and labels from both ends
j ir
44 Optical cables fixing and clamped on tower & without cross
j ir
45 Jumpers weatherproofed & Labeled from RRU Side & Antenna Side
j ir
46 Antenna directions and tilt angles and height according RF design
j ir
47 Antenna fittings tightened and Antenna without damage
j ir
48 Maximum VSWR is less than 1.3
j ir
49 No Rubbish after swap installation
j ir
50 No Dismantle Materials on site
j ir
51 All ground cables connected without Daisy chain
j ir
52 Key and IT cable available on site
j ir
53 All new installed Busbar should be installed/isolated properly
j ir
54 No potential security hazard.
j ir
55 Site secured. Doors are locked tight.
j ir
56 clear alarm from NMC & SO EM
j ir
57 Antenna Mechanical Tilt installation (Mechanical tilt =0)
j ir
58 all link budget, RF design ,Huawei standard to be handed over to O&M on site j
j mrrAzimuth (Degree)
Antenna height
# Sector ID Leg No. M -Tilt (Degree)
(from ground)
r
1 Sector 1 r
2 Sector 2 r
3 Sector 3
4 Sector 4
# EXTERNAL ALARM DESCRIPTION. Status Comments
1 SHELTER DOOR OPEN (for indoor only) i
i
2 HIGH ROOM TEMPERATURE 32°C (for indoor only)
j i
3 AIRCON (1) FAILURE  (for indoor only)
j i
4 AIRCON (2) FAILURE  (for indoor only)
j i
5 GENERATOR 1 FAILURE
j ir
6 GENERATOR 2 FAILURE
j ir
7 GENERATOR LOW FUEL ALARM
j ir
8 AVIATION LIGHT FAILURE
j ir
9 AC MAINS FAILURE
j ir
10 RECTIFIER FAULT ALARM
j ir
11 RECTIFIER MAJOR
j ir
12 RECTIFIER MINOR
j ir
13 DC LOW VOLTAGE ALARM
j ir
14 FIRE ALARM (for indoor only)
j r
j r