C807 − 18
the mortar mixing procedure and the time a penetration of 10 13. Precision and Bias
mm is obtained is the time of setting.
13.1 The multilaboratory standard deviation has been found
10.4 Precautions—Maintain testing apparatus on a rigid to be 15.2 min. Therefore, the results of two properly con-
surface, free of vibration during the penetration test. Do not oil ducted tests from two different laboratories on samples of the
the plunger of the Vicat apparatus at any time, but keep the same cement should not differ by more than 43 min.
plunger and guide bearing clean at all times.
(See Note 1)
11. Calculation
13.2 No information can be presented on the bias of the
11.1 Calculate the time of setting to the nearest one minute procedure in this test method for measuring time of setting
as follows: because no material having an accepted reference value is
SS ~~ H 2 E!
C 2 D! D
3 ~ C 2 10! 1E D (1)
available.
NOTE 1—These numbers represent, respectively, the 1s and d2s limits
as defined in Practice C670.
where:
E = time in minutes of last penetration greater than 10 mm, 14. Keywords
H = time in minutes of first penetration less than 10 mm,
C = penetration reading at Time E, and 14.1 hydraulic-cement mortar; time of setting; Vicat needle,
D = penetration reading at Time H. expansive
12. Report
12.1 Report the time of setting in minutes, to the nearest one
minute.
SUMMARY OF CHANGES
Committee C01 has identified the location of selected changes to this standard since the last issue (C807 – 13)
that may impact the use of this standard. (Approved Oct. 1, 2018.)
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/
Copyright by ASTM Int'l (all rights reserved); Thu Nov 28 18:35:58 EST 2019
3
Downloaded/printed by
(UNOESTE) UNIVERSIDADE DO OESTE PAULISTA ((UNOESTE) UNIVERSIDADE DO OESTE PAULISTA) pursuant to License Agreement. No further reproductions authorize