Sei sulla pagina 1di 2

Service Bulletin Page 1 of 2

¿ SB-No. SB-6803 Issue Date 23.09.2004


Subject Firmware upgrade (Measures against communication error etc.)

Model Fax System (B), Fax System (C), Fax System (F), Fax System
(G), Fax System (H)

Affected Models: Fax System (B): KM-1530/2030 Fax System (C)/(F): KM-2530/3530/4030
Fax System (H): KM-C2630/C2630D Fax System (G): KM-C850/C850D

[Software List]
Program File Name Check Access
Type
No. (After uncompressing) SUM Time
FAX System (B) Ver.2.28
E833/
IC 1, ROM CONTROL 2AW6801F 2AW6801.FR EAA3
100ns Special tool ROM
7411/
IC 2, ROM CONTROL 2AW6802F 2AW6802.FR 230B
100ns Special tool ROM

Remote software 2AW2931F R2AWV228.HEX -------- -------- FAX data for using PC remote

FAX System (C) Ver.0.95


3CF8/
ROM FAX 1 3CM68016 3CM6801.6G 231B
100ns Special tool ROM / Special tool CF data
4C78/
ROM FAX 2 3CM68026 3CM6802.6G 0ABE
100ns Special tool ROM / Special tool CF data

Remote software R2BHV095 R2BHV095.HEX -------- -------- FAX data for using PC remote

FAX System (F) Ver.1.14


935C/
ROM FAX 1 3DB68017 3DB6801.7H 287A
100ns Special tool ROM / Special tool CF data
FBB0/
ROM FAX 2 3DB68027 3DB6802.7H 8538
100ns Special tool ROM / Special tool CF data
9DCD/
ROM FAX 3 3DB68037 3DB6803.7H B2B2
100ns Special tool ROM / Special tool CF data
0000/
ROM FAX 4 3DB68047 3DB6804.7H 0000
100ns Special tool ROM / Special tool CF data

Remote software R3DBV114 R3DBV114.HEX -------- -------- FAX data for using PC remote

FAX System (G)/(H) Ver.0.43


SOFTWARE CONTEROL 3HZ68064 P3HZ6806.4E4 A659 -------- CF data

Remote software R3HZV043 R3HZV043.HEX -------- -------- FAX data for using PC remote
When upgrading firmware, please upgrade each type of firmware to the newest version at the same time.

Field Measure: If the problem arises, please upgrade firmware.

Affected Machine Serial Nos.: Fax System (B)


Fax System (C)
Fax System (E) From the production in August, 2004 on (Plan)
Fax System (F)
Fax System (G)
Fax System (H)
(CHUNGHO spec. machine is affected.)

Kyocera Mita ESC-QA / Service Division

SB-6803
Service Bulletin Page 2 of 2

Firmware is upgraded as follows.

[Contents of changes]
Item Remarks Ver.
1 Correcting the communication error At ECM reception under certain particular conditions (* 1), even if the 2AW-148

at ECM reception (U00910 or same frame is sent again and again from a transmitter, it is not possible to 3C2-019

U01118) receive the frame. Then communication error might occur. Therefore the 3CM-063
3DB-048
communication error is corrected.
(* 1) In the case that one page is divided into multiple partial pages and
the last page is composed of 1 frame and the size is 256-byte or less.

2 Changing the setting value of The default of software switch [Timeout 1 and 2 against echo] is changed. 2AW-149

timeout against echo as measures SSW 136 Timeout 1 against echo 0FH → 25H 1.5s → 3.7s 3C2-021

against the communication error Bit7-0: 0000 1111 → 0010 0101 3CM-065

U01114 SSW 137 Timeout 2 against echo 0FH → 25H 1.5s → 3.7s 3DB-049

Bit7-0: 0000 1111 → 0010 0101

3 Measures against the error of The change is made so that the error of communication with specific models 2AW-150
(Murata f330, Easy FAX) does not occur.
communication with specific models 3C2-022
(On the above specific models, the interval between DCS and TCF is secured 3CM-066
400ms or more. For that reason, when communicating with the above specific 3DB-050
models, timeout might occur. Therefore the change is made so that the timeout
does not occur.)

4 Correcting the problem that, if We found that there is some kind of problem in judgment process at TCF 3CM-064

signal/noise level is high at V.17 reception. This problem is corrected. 3C2-020

reception, the error code U01143 [Phenomenon]


might be displayed and the The process is performed in the order of TCF reception, judgment, signal
disconnection and the notification of judgment result. However, if noise
reception might result in
level is high, it is not possible to detect signal disconnection and to notify
communication error
the result of judgment.
[Change]
The change is made so that the result of judgment is notified even if the
signal is not disconnected within a certain time.

5 Correcting the problem that, in When the machine status is in sleep mode, even if the machine receives 3DB-047

sleep mode for energy save, the the ringer from a transmitter, there is the possibility that the machine
status of machine does not return might be locked without returning from the sleep mode. Therefore the
from the sleep mode even if the problem is corrected. (This change had been made to the other model.
machine receives the ringer from a This time it is introduced to FAX System (B)/(C)/(E)/(F)/(G)/(H).)
transmitter (The above change is effective by changing the PCB. Regarding the
change of PCB, we will inform later.)

[Note] The above change No.1 to No.3 affects all models.