Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SYSTEM
The next-generation mandible
plating system
OVERVIEW BROCHURE
MatrixMANDIBLE PLATING SYSTEM
The next-generation mandible plating system
Introduction
The aim of surgical fracture treatment is to reconstruct the
bony anatomy and restore its function. According to the
AO,1 internal fixation is distinguished by anatomic reduction,
stable fixation, preservation of blood supply, and early,
active mobilization.2 Plate and screw osteosynthesis has
been established and clinically recognized for some time.
MatrixMANDIBLE System
x Comprehensive anatomic locking plate selection
x Flexibility in selecting best screw and plate combination
x Reduced inventory for hospitals without compromising
clinical solutions
x Simplified instrumentation compared to previous
DePuy Synthes Companies mandible sets
x Color-coding guides the user for correct implant
and instrument selection
Easily accessible
instruments
Organized
instrument
layout
Screws
x Matrix Family drive recess provides for screw/blade
retention and torque transmission for reduced cam-out
compared to previous DePuy Synthes Companies
drive recesses*
x Sizes of 2.0 mm, 2.4 mm, 2.7 mm emergency,
and 2.9 mm diameters with self-retaining drive recess
x All screw diameters work with all plates**
x Screw angulation of 10°–15° depending on plate size
x Off-axis screw insertion up to 15° (screw-to-blade axis)
10º–15°
x Standard screws have 1.0 mm pitch; fine pitch screws
have 0.5 mm pitch
x Made from titanium alloy (Ti-6Al-7Nb)
15º
2.7 mm
2.0 mm 2.4 mm Emergency 2.9 mm
Neutral thread
profile for lower
insertion torque
compared to previous
DePuy Synthes Companies
screws*
Plates
x Conical locking technology for reliable
1.0 mm, malleable
screw-to-plate security
x Made from pure titanium
x Multiple thicknesses to suit a variety of needs
1.0 mm
x Rounded plate profiles and edges
x Improved “angle plate” designs reduce stress
in critical areas*
1.25 mm
x Larger reconstruction plates available for
defect bridging
x Longer ramus section on reconstruction plates
for larger patient anatomy 1.5 mm
2.0 mm
2.5 mm
Rounded profiles
and edges
*Mechanical test data on file at DePuy Synthes Companies. Mechanical test results
are not necessarily indicative of clinical performance.
DePuy Synthes Companies MatrixMANDIBLE Plate DePuy Synthes Companies 2.0 mm MLP Plate
MatrixMANDIBLE Plates 1.0 Malleable 1.0 1.25 1.5 2.0 2.5 2.8
1.5
Microvascular
Recon
2.0
This is a general guideline for out-of-plane bending. Strengths may vary depending on cross section and plate orientation.
Note: The above images depict comparative Finite Element Analysis of comparable
plates subjected to identical simulated bending forces or moments, similar to those
experienced by a fractured mandible. Higher concentrations of stress (shown as
yellow regions) are noticeable in the 2.0 MLP where the plate transitions from the
bar section to the hole section. These stress concentrations are not present in the
Matrix Family plate.
*Data on file at DePuy Synthes Companies. Non-clinical test results are not
necessarily indicative of clinical performance.
Indications Contraindications
The DePuy Synthes CMF MatrixMANDIBLE Plating System is x Acute or chronic, local, or systemic infections
intended for oral, maxillofacial surgery: x Allergy to implant material
x Trauma x Insufficient bone quality to secure implant
x Reconstructive surgery
x Orthognathic surgery (surgical correction of
dentofacial deformities)
Plate thickness Plate type Primary clinical use Secondary clinical use
The Lambda plate 5 hole segment and For Trapezoidal Plate placement,
Strut plate 3 hole segment should be superior placement is limited by the
nearly parallel to the posterior border width of the condylar neck*
and aligned with the condylar head*
Plate thickness Plate type Primary clinical use Secondary clinical use
Plate thickness Plate type Primary clinical use Secondary clinical use
* Plate fractures are possible when any plate bears the entire functional load for
extended periods. Therefore the implantation of a bone graft immediately, or at
a later date, is necessary to support the construct.
Reference: J. Prein, ed. Manual of Internal Fixation in the Cranio-facial Skeleton.
Berlin: Springer. (1998).
Ratcheting handle
allows plate to be
Designated pockets
held in place during
accommodate plate size for
bending. Can be
ease
retracted when
of bending
not needed
Ball registers
in plate hole
to hold the
plate securely Ratcheting handle
allows plate to be
held in place during
insertion. Can be
retracted when
Flat surface allows plate to
not needed
be placed against the bone
Integral deburring
rasp removes burrs
from cut plates
Ergonomic design
allows easy cutting
Integrated
deburring rasp
Plate holding wires hold the plate securely
during and after cutting
MatrixMANDIBLE Self-Retaining
Screwdriver Blades
03.503.070 Short
03.503.071 Medium
03.503.072 Long (shown)
*Also available
*Also available
Label Sheets
306.704 Label Sheet Small Plate Module
306.705 Label Sheet Screw Module
306.706 Label Sheet Large Plate Module
306.735 Label Sheet for 306.731
306.736 Label Sheet for 306.732
306.744 Label Sheet for 306.733
306.762 Strength Gradient Label Sheet
690.612 Screw Length Label Sheet for Calibrated
Drill Bits
2.0 Titanium MatriMANDIBLE Fine Pitch 306.714 Insert Tray for Bending Pliers
Screws (5/pkg.)* 306.745 Reconstruction Screw Caddy Insert Tray,
04.503.554.05 4 mm for MatrixMANDIBLE System
04.503.555.05 5 mm 306.746 2.8 mm Plate Insert Tray, for
04.503.556.05 6 mm MatrixMANDIBLE System
04.503.558.05 8 mm 306.747 2.0 mm and 2.5 mm Double Angle Plate
Insert Tray, for MatrixMANDIBLE System
04.503.761 Titanium MatrixMANDIBLE Plate, 1.25 mm 306.752 Mini IMF Screw Module
thick, 2 x 2 holes
306.755 Lag Screw Module
04.503.780 MatrixMANDIBLE Prebent Tension Band 306.757 Compact IMF Screw Module
Plate, right, 1.0 mm thick, 2 x 2 holes 306.760 IMF Screw Module, Full Size
04.503.781 MatrixMANDIBLE Prebent Tension Band 306.770 2.0 mm Screw Insert Tray
Plate, left, 1.0 mm thick, 2 x 2 holes 306.772 Generic MatrixMANDIBLE Screw Insert Tray,
for 2.0 mm, 2.4 mm and 2.9 mm screws
04.503.783 Titanium MatrixMANDIBLE Adaption Plate,
1.0 mm thick, 4 holes 306.778 Matrix Auxiliary Module, medium
04.503.784 Titanium MatrixMANDIBLE Adaption Plate, 306.781 Insert for 1.0 mm Malleable Plate
1.0 mm thick, 6 holes 306.782 Insert Tray for 1.0 mm plates
306.783 Insert Tray for 1.25 mm plates
04.503.830 Titanium MatrixMANDIBLE Subcondylar 306.784 Insert Tray for 1.5 mm plates
Plate, Lambda, right, 1.0 mm thick
306.785 Insert Tray for 2.0 mm plates
04.503.831 Titanium MatrixMANDIBLE Subcondylar
306.786 Matrix Auxiliary Insert Tray, medium
Plate, Lambda, left, 1.0 mm thick
306.787 Auxiliary Insert Tray, small
04.503.832 Titanium MatrixMANDIBLE Subcondylar
306.789 Insert Tray for Subcondylar Plates for
Plate, Strut, right, 1.0 mm thick
MatrixMANDIBLE
04.503.833 Titanium MatrixMANDIBLE Subcondylar
60.449.005 Module and Lid for Condylar Head Add-on
Plate, Strut, left, 1.0 mm thick
System, MaxtrixMANDIBLE
04.503.834 Titanium MatrixMANDIBLE Subcondylar
Plate, Trapezoidal, 1.0 mm thick
Other:
03.503.700 Bending Insert Holder for 03.503.080
Graphic Case Options
Graphic Case and Instrument Trays: 306.726 Finger Mat, for use with 306.702, medium
306.777 Graphic Case, medium 306.728 Calibrated Drill Bit Holder
306.702 Instrument Tray for Graphic Case, medium, 306.765 Label Sheet for IMF Module
for MatrixMANDIBLE Benders and Cutters 306.766 Label Sheet for Lag Screw Module
306.707 Instrument Tray for Graphic Case, medium, 306.767 Label Sheet for Subcondylar Tray for
MatrixMANDIBLE Trocar and Drivers MatrixMANDIBLE
306.774 Label Sheet for Screw Module
Modules / Insert Trays:
306.788 Label Sheet, Small Plate Insert
306.610 Auxiliary Module
306.82 Plastic Cup with Lid, for Elastomeric Inserts
306.624 Generic Module Lid
306.712 Insert Tray for Trocar Instruments
306.713 Insert Tray for Bending Instruments
www.depuysynthes.com