Sei sulla pagina 1di 22

Up

Down
Enabling
Stage speed1
Stage speed 2

Public end 6

Public end 0
Fault
Running

Surge protector SIST

Added when surge protector is selected Note 1

Add wiring when provided with frequency converter brake unit


Note: Install mechanical chain lock between
Km1, KMU1 and KMD1, KMT1 and KMS1.
Install mechanical chain lock in India Subway
double drive KMS1’ and KMT1’

Dual drive mode circuit


Comb illumination
Independent lead-in i llumination PS

India Subway

Control power and illumination


*** Remove AC36 transformer when no special requirements
Fault display 1 (relay output) Input power

Fault display 2(relay output)

Fault display 3 (relay output)

Fault display 4 (relay output)

Fault display 5 (relay output)


Safe voltage

Elevator stops

Safety inspection
485 changed to CAN
communication plate

Running1 inspection

Running2 inspection

Band-type brake inspection

Main panel inspection pulse

Upper access photoelectricity

Lower access photoelectricity

Up inspection

Down inspection

Upper access Mode selection


photoelectr icity

Stop elevator by BAS remote


contrlol(firefighting)
India Subway

D own access
photoelectr icity
Double drive mode input circuit
India Subway

Double drive mode output circuit


XPI-U
SXI-D inspection socket SXI-U inspection socket XPI-D additional socket XIB socket XIB inspection operation handle

Inspection

Up startup

Down starup

India Subway

Inspection circuit
Handrail drive Right main drive Left main drive Up emergency stop Up right handrail in Up left handrail in Up right comb1 Up right comb2

For double-drive

Middle left skirt guard Middle right skirt guard Middle emergency right Middle emergency left Up cascade caving Up left de-bouncing Up left skirt guard Up right skirt guard Up left comb2 Up left comb1

Down forefront board Right drive thermal control Left drive thermal control
Upper box emergency stop Upper additional socket Up forefront board Lower additional socket Main box emergency stop Phase sequence relay

Upper inspection emergency stop

Lower inspection emergency stop

Down middle right skirt guard Down left comb2 Down left comb1 Down right comb2 Down right comb1 Down left handrail in Down right handrail in Lower emergency stop Left cascade chain Right cascade chain Ground protector

Down middle left skirt guard Down right skirt guard Down left skirt guard Left handrail Down right de-bouncing Down cascade caving Lower box emergency stop
Right handrail

India Subway

Safe circuit
Upper box
emergency stop

Middle emergency
stop right

Middle emergency
stop left

Wiring is used when


middle emergency stop
Upper left comb 1

Upper left comb 2 Right main drive

Upper right comb 1


Left main drive
Upper right comb 2

Upper left Handrail drive


skirt guard

Upper step
Upper right caving in
skirt guard

Upper
U pper middle emergency stop
left skirt guard

Upper left
de-bouncing
U pper middle
Fault collection board of upper machine room

righ t skirt guard


Main control cabinet
emergency stop
Upper left
handrail in

Upper right
handrail in

Left drive
thermal control

Right drive
thermal control

Phase sequence
relay

Leakage current
relay
India Subway

Upper fault collection


Lower box
emergency stop

Lower left comb 1

Lower left comb 2

Lower right comb 1

Lower right comb 2

Lower left skirt guardd

Lower right skirt guardd

Lower left
handrail IN

Lower right
handrail IN

Left s tep chain

Right s tep chain

Left handrail

Ritht handrail

Lower step caving


Fault collection board of lower machine room

Lower box
emergency stop

Lower right
de-bouncing

Lower step caving

Lower-middle-right
India Subway

skirt guard

Lower-middle-left
skirt guard
Lower fault collection
Additional brake
contactor

Additional brake
feedback

Upper machine
room cover board

For dual-drive
Lower machine
room cover board

Temperature
detection

Motor thermistor
Add dual-drive

brake wear

Lubricant level

Smoke detection

Add dual-additional brake


Water level alarm

Fire control alarm bell


and lamp output
India Subway

extended function
Auxiliary brake and
Fault collection panel Fault dispaly panel Fault dispaly panel Fault collection panel

Position:control cabinet Position:upper skirt guard Position:lower skirt guard Position:lower control box

Main control Dual-drive Function RS485 Parallel


board expansion board expansion board monitoring board monitoring board

Position: Position: Position: Position: Position:


control cabinet control cabinet control cabinet control cabinet control cabinet

Serial data
Parallel data

Monitoring room

India Subway

General drawing
of control system
India Subway

Contactor wiring table


Upper smart photoelectric wiring diagram Lower smart photoelectric wiring diagram

Metal wire Metal wire

Black wire Black wire

Blue wire Blue wire


Brown wire Brown wire

Metal wire Metal wire

Black wire Black wire

Blue wire Blue wire

Brown wire Brown wire

Note: one LT and one LR detectors are deemed as one group during India Subway
the installation and shall be installed on the same side.
Photoelectric sensing
Main engine speed
measurement signal 1
PCB power supply

Main engine speed


measurement signal 2

Upper step missing 1

Lower step missing 1

Handrail speed Fault display 1(relay output)


measurement signal 1

Fault display 2(relay output)


Handrail speed
measurement signal 2
Fault display 3(relay output)
Running signal
Fault display 4(relay output)

Up input signal Fault display 5(relay output)

Opticalcoupler output 1
Down input signal ( main board verification )

High speed
contactor detection

Additional contactor
detection

Additional brake
SW detection

Band-type brake
feedback detection 1

Band-type brake
feedback detection 2

Driving chain
SW detection

INSP signal

Fault reset signal


India Subway

Functional safety board


Small terminals in terminal box

Small terminals in lower box

India Subway

Terminals in t erminal b ox
Main control cabinet connecting cable 1
Car control panel
Connector No. Pin No. DWG line No. Cable line No. DWG line No. Remarks
Control cabinet socket : 171830-1

Cable plug: 171364-1

India Subway

Main control cabinet


connecting cable 1
Main control cabinet connecting cable 2
Car control panel
Connector No. Pin No. DWG line No. Cable line No. DWG line No. Remarks
Control cabinet socket : 171830-1

Cable plug: 171364-1

India Subway

Main control cabinet


connecting cable 2
Main control cabinet connecting cable 3
Car control panel
Connector No. Pin No. DWG line No. Cable line No. DWG line No. Remarks
Control cabinet socket : 171830-1

Cable plug: 171364-1

India Subway

Main control cabinet


connecting cable 3
Main control cabinet connecting cable 4
Car control panel
Connector No. Pin No. DWG line No. Cable line No. DWG line No. Remarks
Control cabinet socket : 171830-1

Cable plug: 171364-1

India Subway

Main control cabinet


connecting cable 4
Upper and lower
connecting cables 1

Twisted pair shield


India Subway

Upper and lower


connecting cables
connecting cables 2
Upper and lower

India Subway

Upper and lower


connecting cables
Comp. Code Comp. Def. Model & specs Placement Remarks Comp. Code Comp. Def. Model & specs Placement Remarks
Main PS SW Main control cabinet Vary with power Upper machine room cover board Upper machine room
Running contactor Main control cabinet Vary with power Lower machine room cover board Lower machine room
Up contactor Main control cabinet Vary with power Inspection socket Upper control cabinet
Down contactor Main control cabinet Vary with power Inspection socket Lower control cabinet
Phase sequence relay Main control cabinet Upper step illumination Upper truss
Termal protection for motor Main control cabinet Lower step illumination Lower truss
Upper machine room Vary with power Step speed measurement Drive chain wheel
Brake Three-phase Ac220 photoelectricity A
Upper machine room Step speed measurement Drive chain wheel
Traction machine Three-phase AC380 photoelectricity B
Upper machine room Step speed measurement Drive chain wheel
Traction machine Three-phase AC380 photoelectricity C
Star running contactor Step speed measurement Drive chain wheel
Main control cabinet photoelectricity D
Triangle running contactor Main control cabinet Handrail speed measurement A Lower metal wheel
Star running contactor Main control cabinet Handrail speed measurement B Lower metal wheel
Triangle running contactor Main control cabinet Escalator stopping skirt guard
Stand-by PS PS Main control cabinet Band-type brake SW 1 Upper machine room
Buzzer Main control cabinet Band-type brake SW 2 Upper machine room
Converter YASKAWA Main control cabinet Vary with power Upper access photoelectricity Access skirt guard
Braking resistance Main control cabinet Vary with power Lower access photoelectricity Access skirt guard
Running 1 contactor Main control cabinet Mode select switch Upper skirt guard
Running 2 contactor Main control cabinet Upper direction light / green Upper Handrail end
Up contactor detection Main control cabinet Upper direction light / red Upper Handrail end
Down contactor detection Main control cabinet Lower direction light / green Lower Handrail end
Running 1 detection contactor Main control cabinet Lower direction light / red Lower Handrail end
Star running contactor Main control cabinet Inspection box upward button Inspection box device
Triangle running contactor Main control cabinet Inspection box downward button Inspection box device
Star running contactor Main control cabinet Inspection box running button Inspection box device
Triangle running contactor Main control cabinet Inspection box EMER stop button Inspection box device
Safety circuit contactor Main control cabinet Inspection operating handle Inspection box device
Band-type brake detection contactor Main control cabinet Water level detection relay Lower machine room
Transformer Temperature detector Machine room &
Main control cabinet main control cabinet
Three-pole socket panel Lower control cabinet Smoke detector Machine room &
main control cabinet
Three-pole socket panel Upper control cabinet Electronic arc extinguisher Main control cabinet

India Subway

Details of components
Comp. Code Comp. Def. Model & specs Placement Remarks Comp. Code Comp. Def. Model & specs Placement Remarks
Upper end key switch Upper skirt guard Lower emergency stop Truss
Lower end key switch Lower skirt guard Lower right handrail in Handrail access
Fuse ( Fuse core 2A ) Upper control cabinet Lower left handrail in Handrail access
Fuse ( Fuse core 10A ) Upper control cabinet Lower right comb Comb plate
Fuse ( Fuse core 2A ) Upper control cabinet Lower left comb Comb plate
Fuse ( Fuse core 10A ) Upper control cabinet Lower right comb Skirt guard
Handwheel open Upper machine room Lower left comb Skirt guard
Handrail drive Truss Right handrail Truss
Right handrail drive Truss Left handrail Truss
Left handrail drive Truss Upper de-bouncing Truss
Right main drive Driving chain Upper step caving Truss
Left main drive Driving chain Lower box emergency stop Lower machine room
Upper emergency stop Truss
Additional brake contactor Main control cabinet
Upper right handrail in Handrail access
Upper left handrail in Handrail access Additional brake feedback Truss
Upper right comb Comb plate
Upper left comb Comb plate
Upper right skirt guard Comb plate
Upper left skirt guard Comb plate
Upper de-bouncing Truss
Upper step caving Truss
Middle emergency stop Handrail
Middle right skirt guard Comb plate
Middle left skirt guard Comb plate
Upper box emergency stop Main control cabinet
Right drive thermal control Main control cabinet
Left drive thermal control Main control cabinet
leakage current relay Upper control cabinet
Right cascade chain Lower machine room
Left cascade chain Lower machine room
Brake wear Upper machine room

India Subway

Details of components

Potrebbero piacerti anche