3.1.3.1 BTS3911B
The BTS3911B is equipped with internal antennas. This topic describes its appearance,
dimensions, ports, and indicators.

Appearance

Dimensions
Ports

Table 1 Port description

No. Port Description

1 Micro SD Used for housing a MicroSD card. This is used for deployment.

2 Mini USB Used for testing clock output.

3 Micro SIM Used for housing a micro SIM card. This is reserved for EAP-AKA
authentication.

4 PoE Used for power supply and data transmission.

5 RGPS Used for clock synchronization.


Table 1 Port description

No. Port Description

6 Used for anti-theft of the BTS3911B. Anti-theft locks are not provided
with the BTS3911B, and can be supplied by customers if required.

Indicators

Table 2 Indicators

Silkscreen Meaning Status Description

3GPP Cellular Blinking white (on for 0.125s The cellular processing unit's high-
processing unit and off for 0.125s) level software is being loaded.
status
Blinking white (on for 1s and off The cellular processing unit cell is
for 1s) starting up.

Steady white All cellular processing unit cells are set


up successfully. S1 links and O&M
links are functional.

White is off The cellular processing unit is not


powered on.

Blinking orange (on for 0.125s An upgrade using a MicroSD card has
and off for 0.125s) failed.
This is a reserved status.

Blinking orange (on for 1s and IKE negotiation has failed for the
off for 1s) cellular processing unit.

Steady orange The cellular processing unit is faulty.


Replace the BTS3911B.

Alternating orange and white An upgrade using a MicroSD card is in


(on for 0.125s and off for progress.
0.125s) This is a reserved status.

Orange is off No hardware-related alarm is generated


on the cellular processing unit.

ETH ETH status Blinking white Data transmission over the Ethernet
port is normal.
Table 2 Indicators

Silkscreen Meaning Status Description

Steady white An Ethernet cable is correctly


connected to the Ethernet port.

Steady off An Ethernet cable is incorrectly


connected to the Ethernet port.

WIFI Wi-Fi Blinking white (on for 0.125s The Wi-Fi processing unit is being
processing unit and off for 0.125s) powered on and software is being
status loaded.

Blinking white (on for 1s and off The Wi-Fi processing unit is starting
for 1s) up.

Steady white The Wi-Fi processing unit is providing


services properly and the O&M link is
functional.

White is off The Wi-Fi processing unit is not


powered on.

Steady orange The Wi-Fi processing unit is faulty.


Replace the BTS3911B.

Orange is off No hardware-related alarm is generated


on the Wi-Fi processing unit.

LINK Link status Steady white The CAPWAP link is normal.

Steady orange The CAPWAP tunnel is disconnected.

Steady off The Wi-Fi processing unit does not


obtain an IP address.

Parent topic: Product Introduction

3.1.3.2 Auxiliary Devices


This section describes the appearance, dimensions, ports, and indicators of the PSE, and the PSE
specifications.
The PSE supplies power to a BTS3911B through an Ethernet cable in PoE mode.
Appearance and Dimensions
Figure 1 shows the appearance and dimensions of the PSE.
Figure 1 Appearance and dimensions of the PSE

Ports and Indicators


Figure 2 shows the ports and indicators on the PSE.
Figure 2 PSE ports and indicators

Table 1 describes PSE ports.


Table 1 PSE ports

No. Label Meaning

1 - Power supply port used for PSE power supply

4 DATA Data input port connecting to a transmission device

5 PoE PoE output port connecting to the BTS3911B

Table 2 describes PSE indicators.

Table 2 PSE indicators

No. Label Status Description

2 AC Steady green The power supply is normal.

Steady off There is no power input or the PSE is faulty.

3 PORT Steady green The connection to the BTS3911B is normal.

Steady off The connection to the BTS3911B is abnormal


or the PSE is faulty.

Specifications
Table 3 lists PSE specifications.

Table 3 PSE specifications

Item Specifications

Input voltage 90 V AC to 264 V AC

Input voltage frequency 47 Hz to 63 Hz

Output voltage -56 V DC

Parent topic: Product Introduction

3.1.4 Installation Scenarios


This topic concerns installation scenarios.

Installation Installation Requirement Installation Diagram


Scenario Mode

Wall Drilling holes  The wall can bear a load at least


mounting four times the weight of a BTS3911B.
 If screws are tightened with a
torque of 1.5 N·m, the screws work
properly and the wall keeps intact.

Using a plate  The wall can bear a load at least


four times the weight of a BTS3911B.
 The wall is 45 mm thick at most.

NOTE:
 When the wall is not able to bear four times the weight of the BTS3911B (this includes
weak walls, such as EPS or MDF walls, and walls that cannot be drilled), add an attachment
plate. Follow the above installation instructions to secure the BTS3911B onto the attachment
plate. Attachment plates are prepared by customers.
 The BTS3911B weights 2 kg or less.

Ceiling Drilling holes  The ceiling can bear a load at least


mounting four times the weight of a BTS3911B.
Concrete ceilings are typically able to
bear the required load.
 If screws are tightened with a
torque of 1.5 N·m, the screws work
properly and the ceiling keeps intact.

Using a plate  The ceiling can bear a load at least


four times the weight of a BTS3911B.
Concrete ceilings are typically able to
bear the required load.
 The ceiling is 45 mm thick at
most.
Installation Installation Requirement Installation Diagram
Scenario Mode

Using a keel  The keel can bear a load at least


four times the weight of a BTS3911B.
 The BTS3911B can be installed
on a U-shaped, T-shaped, or H-shaped
keel. The suitability of keels of other 1. Plate
shapes is determined based on site 2. U-shaped keel
requirements.

Using steel  The steel hangers can bear a load


hangers at least four times the weight of a
BTS3911B.
 M6 and M8 steel hangers are
allowed.
 Steel hangers are prepared by
customers.

Pole mounting The pole diameter ranges from 60 mm to


114 mm or from 114 mm to 381 mm.

Parent topic: BTS3911B Installation Guide

3.1.5 Clearance Requirements


This topic covers clearance requirements for installation of the BTS3911B and PSE.

BTS3911B
PSE

Parent topic: BTS3911B Installation Guide