Wall thickness measurement report


Pipe system: MPD SYSTEM SAP task No:

xxx Inspector's name: NDT Certificate Report No.: Enclosure No.:

Drawing number: Material specification: Nominal outside diameter Yield strength: Ultimate strength:
xxx ASTM A106 GR. B 168,3 mm 241 N/mm2 414 N/mm2
ASTM A234 WPB 168,3 mm 483 N/mm2 621 N/mm2
AISI 4130 ALLOY STEEL
;;;;;klk
Design temperature: Max. working pressure: Permissible stress Min. reqd. wall thickness: Total pages:
90 °C 1440 PSI 138 N/mm2 As per TML mm
203 N/mm2
1
Ultrasonic thickness gauge, type/no.: Calibrated sound velocity: m/sec.

Key location Nominal Minimum required 1st measurement 2nd measurement 3rd measurement 4th measurement
thickness, mm thickness, mm
TML Date: Date: Date: Date:
MPD001 21,95 4,48
MPD002 21,95 4,48
MPD003 21,95 4,48
MPD004 21,95 6,24
MPD005 21,95 6,24
MPD006 21,95 6,24
MPD007 21,95 6,24
MPD008 21,95 6,24
MPD009 21,95 7,53
MPD010 21,95 7,53
MPD011 21,95 7,53
MPD012 21,95 7,53
MPD013 21,95 5,17
MPD014 21,95 6,24
MPD015 21,95 6,24
MPD016 21,95 6,24
MPD017 21,95 5,17
MPD018 21,95 5,17
MPD019 21,95 6,24
MPD020 21,95 6,24
MPD021 21,95 6,24
MPD022 21,95 6,24
MPD023 21,95 5,88
MPD024 21,95 7,53

Wall thickness readings below minimum required wall thickness will be marked as "Fault "
Location inaccessibility codes: A = External surface restrictions B = No scaffold C = Other restrictions

NDT-OPERATOR OWNER'S REPRESENTATIVE CLASS AUTHORITY


Name: Name: Name: