Kalkulasi Katodik Pipa Casing

a. Surface Area Calculation

S/A = π X OD X L

S/A :Surface Area, m2


OD :Outside Diameter of Pipe, mm 0,406
L :Length of Pipe, m 18
π :Phi 3,14

m
S/A = : 22,97 ²

b. Current Demand

I = S/A x DCD

I :Current demand, A
S/A :Surface Area, m2
DCD :Design Current Density on coated line, mA/m2

For the 16" OD underground casing pipe at River Crossing 9


I :0,0125

c. Anode quantity based on total weigth requirement

WL Total weight in lifetime


I Current requirement (A) 0,01
t Lifetime (20 years) 20
Anode capacity (1100 Amp.
AC Hr/Kg) 1100
U Utility factor (0.8) 0,8

WL = 45,73 kg

Jumlah Magnesium Anode 4

Standard Referensi : ISO 15589


Sumber Dari Design Current Density

DCD = 0,0125

Berdasarkan Tabel 3 Typical Design Curent Density

Hal 23 ISO 15589