V E N R kW = ABSORBED LOAD(kVA) * COSp / EFFICIENC kVAr = kW * TANp
I S O E POWER kW = ABSORBED LOAD(HP) * 0,746 / EFFICIENCY T S N S EFFICIENCY FACTOR A E - T (PF) EQUIPMENT DESCRIPTION L N E A ABSORBED NON- MOTOR MOTOR LOAD AT LOAD AT LOAD NO. T S R LOAD RATING RATING FACTOR FACTOR FACTOR CONTINUOUS INTERMITTENT STAND - BY REMARKS I S T AND SPARES A E I L N N T G kVA or HP kVA HP kW kVAr kW kVAr kW kVAr 1 XXX-YY-1 LOAD 1 X 40.50 45.00 0.90 0.90 0.90 40.50 19.62 2 XXX-YY-2 LOAD 2 X 9.49 10.55 0.90 0.90 0.85 8.96 5.55 3 XXX-YY-3 LOAD 3 X 18.00 20.00 0.90 0.90 0.88 17.60 9.50 4 XXX-YY-4 LOAD 4 X 18.00 20.00 0.90 0.88 0.88 15.25 8.23 5 XXX-YY-5 LOAD 5 X 54.00 60.00 0.90 0.90 0.90 44.74 21.67 6 XXX-YY-6 LOAD 6 X 112.50 125.00 0.90 0.93 0.93 90.21 35.65 7 XXX-YY-7 LOAD 7 X 112.50 125.00 0.90 0.93 0.93 90.21 35.65 8 XXX-YY-8 LOAD 8 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 9 XXX-YY-9 LOAD 9 X 9.00 10.00 0.90 0.90 0.85 7.46 4.62 10 XXX-YY-10 LOAD 10 X 9.00 10.00 0.90 0.88 0.85 7.63 4.73 11 XXX-YY-11 LOAD 11 X 135.00 150.00 0.90 0.93 0.93 108.25 42.78 12 XXX-YY-12 LOAD 12 X 135.00 150.00 0.90 0.93 0.93 108.25 42.78 13 XXX-YY-13 LOAD 13 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 14 XXX-YY-14 LOAD 14 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 15 XXX-YY-15 LOAD 15 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 16 XXX-YY-16 LOAD 16 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 17 XXX-YY-17 LOAD 17 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 18 XXX-YY-18 LOAD 18 X 4.50 5.00 0.90 0.85 0.85 3.95 2.45 19 XXX-YY-19 LOAD 19 X 9.00 10.00 0.90 0.88 0.85 7.63 4.73 20 XXX-YY-20 LOAD 20 X 9.00 10.00 0.90 0.88 0.85 7.63 4.73 21 XXX-YY-21 LOAD 21 X 18.00 20.00 0.90 0.88 0.85 15.25 9.45 22 XXX-YY-22 LOAD 22 X 9.00 10.00 0.90 0.88 0.85 7.63 4.73 23 XXX-YY-23 LOAD 23 X 9.00 10.00 0.90 0.88 0.85 7.63 4.73 24 XXX-YY-24 LOAD 24 X 13.50 15.00 0.90 0.88 0.90 10.30 4.99 25 XXX-YY-25 LOAD 25 X 112.50 125.00 0.90 0.93 0.93 90.21 35.65 26 XXX-YY-26 LOAD 26 X 22.50 25.00 0.90 0.90 0.93 23.25 9.19 MAX NORM RUNNING PLANT LOAD: PEAK LOAD: PF W/O COMPENSATION ( COSp ): 0.91 ( X * CONTINOUS LOAD + Y * INTERMITTENT LOAD ) ( X * CONTINOUS LOAD + Y * INTERMITTENT LOAD + Z * STAN-BY AND SPARES LOAD ) TOTAL 364.41 165.99 150.44 67.50 221.33 92.61 482.88 kVA 439.64 kW 506.88 kVA 461.77 kW PF W/ COMPENSATION ( COSpd1 ): 0.91 199.74 kVAr 209.00 kVAr kW; kVAr; kVA =(kW2 + kVAr2)1/2 kW; kVAr; kVA =(kW 2 + kVAr2)1/2 kVA =(kW2 + kVAr2)1/2 400.44 164.89 239.93 REQUIRED CAPACITOR RATING : 0 COINCIDENCE FACTORS X,Y AND Z SHALL EQUAL 1, 0.5, 0.1 RESPECTIVELY. kVAr = kW * (TANp - TANpd1 ) NOTES: A) ABSORBED LOADS: B) CONSUMED LOADS: "STAND - BY AND SPARES": LOADS REQUIRED - FOR PUMPS, SHAFT LOAD ON DUTY POINT; "CONTINUOUS": ALL LOADS THAT MAY CONTINUOUSLY IN EMERGENCIES, SUCH AS FIRE - WATER - FOR INSTRUMENT., COMPUTERS, COM., AIR COND., BE REQUIRED FOR NORMAL OPERATION, INCLUDING PUMPS. STAND-BY ELECTRIC MOTORS FOR THE REQ'D LOAD DURING FULL OPER. OF PLANT; LIGHTING AND AIR-CONDITIONING. TURBINE-DRIVEN EQUIPMENT. ALL SPARE - FOR LIGHTING DURING DARK HOURS; " INTERMITTENT " THE LOADS REQUIRED FOR ELECTRIC MOTORS. - FOR WORKSHOPS, THE AVERAGE TOTAL LOAD INTERMEDIATE PUMPING, STORAGE, LOADING, ETC. AND IN NORMAL FULL OPERATION. CONVENIENCE RECEPTACLES AND WORKSHOP LOADS. CONTR. JOB NO. PROJECT TITLE: PRINCIPLE: CONSIGNEE: FIRST ISSUE REV. LETTER 0 1 2 3 4 0 UTILITY DATA - ELECTRICAL DATE DOCUMENT No. SHEET No REV.
Assessment of Spinach Seedling Health Status and Chlorophyll Content by Multivariate Data Analysis and Multiple Linear Regression of Leaf Image Features