2/27/2020 Software History

Generator Set
Genset Control
GENERATOR CONTROLLER_1

582-5814-00 RELEASE NOTES


Notice
Service information will be available and may provide greater detail.

Miscellaneous Information
Required Service Tool

Cat® ET, release 2019 B or later

Related CPI Issue

435533

Replaces Part Number

518-8916-00

Software Changes
EMCP 4.1, v4.4.4L - Low End (English)
1. Removed 'Low Shutdown' selection from display when System Event is configured for Exhaust Temperature
2. Extended engine hours range on EMCP display to 596k hours
3. Added support for DTC occurrence count greater than 99
4. Integrated voltage regulator starting time and crank terminate rpm setpoint values are now retained across EMCP power cycle
5. Broadcast SPN96 when an analog input is configured as Fuel Level %
https://sisweb.cat.com/sisweb/servlet/cat.dcs.sis.controller.CSSISFileDownloadServlet?filerid=24175874&filetype=html 1/3
2/27/2020 Software History

6. Added support for additional engine events


7. Added 'Engine Speed Based Generator Frequency Calculation Enable' as an alternate method of calculating frequency based on engine speed and generator poles. This
selection will be available in Caterpillar ET 2019B.

CPI 435533
EMCP software is updated to detect tooth abutment and disengage starter pinion by aborting the start attempt. Starter will be reengaged for a subsequent attempt up to the
smaller of configured maximum number of attempts or 3 failed attempts. This strategy will be enabled by default in EMCP.

When 'Engine Operating State Input Configuration' is set to 'Hardwired Input', EMCP expects to have engine starter control and will execute tooth abutment strategy. If this
configuration is set incorrectly, this software will result in failed engine start attempts. EMCP display and Service Tool version 2019C will have the option to disable the tooth
abutment check.

518-8916-00 RELEASE NOTES


Miscellaneous Information
Required Service Tool

Cat® ET, release 2016 C or later

Replaced by Part Number

582-5814-00

Software Changes
EMCP 4.1, v4.4.2L - Low End (English)
1. Display software update to improve the liters to gallons conversion.
2. Updated fuel level #7 calculations to valid range and improve fuel sensor diagnostics.
3. Added support for EMCP hardware and software information over J1939 for Telematics device.
4. Improved MW and MVA rating resolution.
5. Software update to improve Phase Rotation check for 3PH 3W configuration.
6. Added 'Engine Not Running' selection to Digital Output Relay programmable options.
7. Software update to retain IVR (Integrated Voltage Regulator) starting time when programmed for less than 3.0 seconds.
8. Software update to retain Crank Terminate setpoint when programmed for less than 100 RPM.
9. Software update to include new Event text string for SPN 3516-2.

https://sisweb.cat.com/sisweb/servlet/cat.dcs.sis.controller.CSSISFileDownloadServlet?filerid=24175874&filetype=html 2/3
2/27/2020 Software History

© 2019 Caterpillar Inc. All rights reserved. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," as well as corporate and product identities used herein, are trademarks of Caterpillar and may not be used
without permission.

Caterpillar: Confidential Green

https://sisweb.cat.com/sisweb/servlet/cat.dcs.sis.controller.CSSISFileDownloadServlet?filerid=24175874&filetype=html 3/3

Potrebbero piacerti anche