Sei sulla pagina 1di 4

I dont think that someone has configured the rsc console port on the nodes V890 by defeault

Try following user/password combination -> admin / siemens!

If not working configure the rsc interface:

rsc interface configuration:

Following packages should be installed on Server:


pkgadd -d . SUNWrsc SUNWrscd SUNWrscj

Location of scripts:

# pwd
/usr/platform/SUNW,Sun-Fire-V890/rsc
# ls
rsc-config rsc-initscript rscadm

Configuration of rsc interface:

./rsc-config

Continue with RSC setup (y|n): y

Set RSC date/time now (y|n|?) [y]:


Server Hostname [b2b-app4]:
Edit customer info field (y|n|?) [n]:
Enable RSC Ethernet Interface (y|n|s|?) [y]:
RSC IP Mode (config|dhcp|?) [config]:
RSC IP Address [10.2.2.157]:
RSC IP Netmask [255.255.255.0]:
RSC IP Gateway [10.2.2.1]:
Enable RSC Alerts (y|n|s|?) [y]:
Enable Email Alerts (y|n) [n]:
Enable Pager Alerts (y|n) [n]:
Enable RSC Modem Interface (y|n|s|?) [n]:
Enable RSC Serial Port Interface (y|n|s|?) [y]:
Serial port baud rate (9600|19200|38400|57600|115200) [9600]:
Serial port data bits (7|8) [8]:
Serial port parity (even|odd|none) [none]:
Serial port stop bits (1|2) [1]:
Setup RSC User Account (y|n|?) [n]: y
Username [root]:
User Permissions (c,u,a,r|none|?) [bacher01]: cuar

--------------------
Verifying Selections
--------------------

General Setup
-------------
Set RSC date now = y
Server Hostname = b2b-app4
Set Customer Info = n

Is this correct (y|n): y

Ethernet Setup
--------------
IP Mode = config
IP Address = 10.2.2.157
IP Netmask = 255.255.255.0
IP Gateway = 10.2.2.1

Is this correct (y|n): y

Alert Setup
-----------
Email Enabled = n
Paging Enabled = n

Is this correct (y|n): y

Modem Setup
-----------
- Modem disabled, ppp disabled

Is this correct (y|n): y

Serial Port Setup


-----------------
Serial Port Baud = 9600
Serial Port Data Bits = 8
Serial Port Parity = none
Serial Port Stop Bits = 1

Is this correct (y|n): y

User Setup
----------
User Name = root
User Permissions = cuar

Is this correct (y|n): y

This script will now update RSC, continue? (y|n): y


Updating flash, this takes a few minutes
........................................
........................................
........................................
........................................
........................................
........................................
........................................
...........................
Download completed successfully

Resetting RSC (takes about 90 seconds): DONE


Setting up server to update RSC date on boot: DONE
Setting up server hostname: DONE
Setting up ethernet interface: DONE
Disabling e-mail alerts: DONE
Disabling pager alerts: DONE
Disabling modem interface: DONE
Setting up serial port interface: DONE
Adding user to RSC:

A valid password is between 6 and 8 characters, has at least


two alphabetic characters, and at least one numeric or special
character. The password must differ from the user's login name
and any reverse or circular shift of that login name.
Setting User Password Now ...

Password:
Re-enter Password:
User has been added to RSC
Resetting RSC (takes about 90 seconds):
Are you sure you want to reboot RSC (y/n)? y

DONE
Setting up RSC date: DONE

*******************************
RSC has been successfully setup
*******************************

Change OPB Settings for output device

im OBP mode:
ok setenv diag-out-console true
ok setenv input-device rsc-console
ok setenv output-device rsc-console

Running Solaris:
# eeprom “diag-out-console=true”
# eeprom “input-device=rsc-console”
# eeprom “output-device=rsc-console”

Hope that will work

mfg
Herbert

Von: Kashif Islam (Siemens) [mailto:kashif.islam-se@telenor.com.pk]


Gesendet: Freitag, 12. Oktober 2007 07:25
An: Bojtos, Gergely Krisztian; Rohonczy, Markus; Ungersboeck, Herbert
Cc: IN-NSN; Hajira Saquib (Siemens)
Betreff: rsc passwords + NET MGT access
Wichtigkeit: Hoch

Dear SX Collegues

Can you please provide us rsc password for SX machines

i.e
xcx1
xlogin-node1
xlogin-node2
TMD 1 , 2 ,3
XBonus 1,2,3

For x5chris I have created it its admin , admin123

Most of time whenever there is an emergency (which is more often these days due to power
problems) we are unable to logon to mchine

Using serial MGT port.


Also for our V240 Sun machines we assign their MGT port an IP so we can bring that machine
up through this if networks daemon are not running.

Can we do the same for our V890 MACHINES? If yes can you please send us the procedure?

Best Regards

Kashif Islam

IN Implementation Engineer

Nokia Siemens Networks Pakistan (Private) Ltd.

Telenor Project

Building 5-A, 2nd & 3rd floor


F-7 Markaz, Jinnah Super Market
Islamabad-44000, Pakistan.
Mobile: +92 302 854 1168

Mailto:kashif.islam-se@telenor.com.pk

Internet: www.nokiasiemensnetworks.com

Potrebbero piacerti anche