Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
portability, its designed for hospital bedside & intra-hospital transfer/transport ventilation use
with ..Fast ‘safe-start’ ventilation buttons > Neonate > Infant > Adult
WAVEFORMCARE CAPNOGRAPHY
& TRANSPORT VENTILATION
All Patient use Capnography & Sp02 Optimised Power Fully Adjustable Oxygen
Adults to Infants Optional: Waveform EtC02 6hrs w/hot swap battery Adjustable 02 mixing
Opt {Neonate mode} Sp02 ,SpCO, SpHB +Docking station charging 21 to 100% +HiFlow 02
Robust & Lightweight 8.4 inch Touch Screen Independent Air Supply Patient Data Transfer
Rugged design, compact Configurable display, loops Integrated air turbine Transfer capability for
& portable ~5.7 kg alarms, curves & trends patient data, events
Ventilation can be performed in both pressure and volume controlled modes. Basic ventilation modes can
be combined with additional options, such as PRVC lung protective Volume regulated, PSV plus ETT tube
compensation and advanced CPAP modes ensure optimal patient ventilation. Oxygen measurement is via an
electrochemical oxygen sensor.
EVE Technical Specifications for: EVE-IN2 base & IN3, IN4, IN5, IN6, IN7, IN8
General Parameters
Patient group: ADULT & INFANT, [Optional Pre-term NEONATE] Loops: V(P), V’(V), V’(P)
Classification: IIb According to 93/42 EWG Trend display: 28 trends adjustable
Dimensions: 390 x 340 x 140 [w x h x d] Trend duration: 1hr, 6hr, 12hr, 24hr, 72hr
INTENSIVE CARE TRANSPORT VENTILATION
Weight: ~5.7 kg Curve display: P(t), V(t), V’(t), Optional C02 (t), Plethysmography
Power Supply: Mains to 24VDC Power supply Unit Pplat, Ppeak, Pmean, PEEP, VTe, VTespon, Vtleak
MVe, MVespon, ftotal, fspon, Tinsp, Texsp, V’max,
Mains: 100 - 240 V AC, 50 - 60 Hz Measured values:
V’min, I:E, Resistance (R), Compliance (C)
Battery: 24 V DC, 8 hours RSB, Fi02/02 (EVE-IN), 02 (EVE-TR)
Optional values: EtCo2, Sp02, Pulse, PI, PVI, Spmet, SpHB, SpC0
Battery life: 12 hours with Hot swap battery back-up
Respiratory rate: 1 to 150 bpm
Recharge time: Battery packs from empty 1 to 2 hours
Tinsp: Inspiration time 0.2 to 30 seconds
Ready to Ventilate: EVE is ready to ventilate from power-on and
completion of compliance self-tests in ~60 secs Texp: Expiration time 0.2 to 30 seconds
Optional Charging/ Docking station, Trolley Mount/Stand Tidal volume: 20 to 2000 ml [Infant 3kg to Adults 200+kg]
Docking Stations: Vehicle mount EVE-TR [24 V DC] Optional {Neonate Mode 2ml to 50ml}
Aircraft/Helicopter mount EVE-TR [12-28 V DC] IE Ratio: 1:150 ... 150:1
Gas Supply Air: Integrated turbine [Peak flow > 230 l/min] PEEP: 0 to 25 mbar
02: 2.7 to 6 bar + 0.5 bar, Oxygen 93 compatible Pinsp: 6 to 55 mbar
Device Self-Tests: Automatic device self-tests at ‘each’ power-on to r Psupp: 1 to 55 mbar
ensure full compliance incl 02 cell calibration.
Ramp time: 0.06 to 30 seconds
Ventiltaion Modes: Invasive and Non-invasive ventilation
Trigger Flow: 0.2 to 15 l/min
Pressure & Volume & NIV
Expiratory Trigger: From 5 to 70% of inspiratory flow
PC-CMV, PC-SIMV, PC-ACV, {PC-ACV+}1, CPAP,
CPAP backup, DUOPAP, nCPAP, nPC-CMV, Apnoea: Apnoea duration 1 to 60 seconds
nPC-SIMV, nDUOPAP, VC-CMV, VC-SIMV
High Flow 02: 02 therapy 2 to 60 l/min [Neonates to Adults]
{Optional}
1
MEDACX LIMITED • ALEXANDER HOUSE • 60-62 STATION ROAD • HAYLING ISLAND • HAMPSHIRE • PO11 0EL
02392 469737
info@medacx.co.uk
www.medacx.co.uk