Sei sulla pagina 1di 14

Instruction manual for

iCC7

Rev 1.2
1 CONTENTS
1 Contents .................................................................................................................................. 1
2 iCC7 Touch Panel .................................................................................................................... 2
2.1 General Information .......................................................................................................... 2
2.2 Technical Specifications ................................................................................................... 2
3 User System ............................................................................................................................ 3
4 Screens ................................................................................................................................... 4
4.1 Main Screen: .................................................................................................................... 4
4.2 Trend Screen: ................................................................................................................... 6
4.3 User Menu Screen: ........................................................................................................... 7
4.4 Alarm Viewer Screen: ....................................................................................................... 9
4.5 Language Screen ........................................................................................................... 10
5 Multiple Generator Variants ................................................................................................... 11
6 Troubleshooting & Replacements .......................................................................................... 13
7 Document Revision ................................................................................................................ 13

® Vetaphone June 2018 Page 1 of 13


2 ICC7 TOUCH PANEL

2.1 GENERAL INFORMATION


The unit use resistive touch technology which makes it possible to operate it with gloves on or by
using the end of a pencil or an improvised stylus. The technology limits the iCC7 to only register
single touch.
Do not use a sharp or pointy object as a stylus. It can damage the touch screen.

2.2 TECHNICAL SPECIFICATIONS


The information in the table is only relevant for the iCC7 without the external option unless
otherwise stated.
Warranty 13 months from shipment
Housing material Plastic (PC+ABS)
Certifications CE, FCC, KCC, UL 61010-2-201
Backlight life time 20000 hours
Operating temperature Stand alone: -10°C to +50°C
External: -20°C to +40°C
Storage temperature -20° to +60°C
Humidity 5% – 85% non-condensed
Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65
Cut-out size Stand alone: 186 x 136mm
Screw dimensions for external mounting M4 Screw – Maximum length 10mm + bracket
thickness

® Vetaphone June 2018 Page 2 of 13


3 USER SYSTEM
The user security in the iCC7 is based on a two-level hierarchy. The purpose of the system is to
avoid uneducated changes to a running setup. After 15 minutes of inactivity the user will be logged
out to further ensure no unwanted changes. The different user level requirements will be indicated
in the screen descriptions. The first level is the daily user level, where no login is required. This will
allow the user to change core settings to the daily production such as the power or the density. The
next level is the Operator level. This is for the educated user. The operator level will make it
possible to change crucial parameters.

The password for the operator level:

User: Operator
Password: 246813

® Vetaphone June 2018 Page 3 of 13


4 SCREENS

4.1 MAIN SCREEN:

General information for the generator and the corresponding transformer and station. Designed to
give a quick overview. The screen will display the current Power and Density. If the generator is in
Power (Watt)-mode it will display the corresponding density calculated by:

ܹܽ‫ݐݐ‬
W · min/m² =
ܵ‫݀ݐ݅ݓ ݁݀݋ݎݐ݈ܿ݁ܧ ∗ ݀݁݁݌‬ℎ ∗ ܰ‫ݏ݁݀݋ݎݐ݈ܿ݁ܧ ݂݋ ݎܾ݁݉ݑ‬

If the generator is in Automatic (W·min/m²)-mode it will display the watt required and used.

8
1

2 9
3
4 10
5 11
14 15
6 12
7 13

® Vetaphone June 2018 Page 4 of 13


# Action User Level Description
1 Input Field None Displays the current selected power or density selected. Will
flash an error message if there an active alarm on the
generator. Click the number to directly input specific Power
or Density
2 Button None Start the Corona treatment
3 Button None Stop the Corona treatment
4 Button None Decrease Watt by 100, W·min/m² by 1, or W·min/ft² by 0.1.
5 Button None Increase Watt by 100, W·min/m² by 1, or W·min/ft² by 0.1.
6 Button None Open the associated electrode. In the open position state
the button will be white. (Optional)
7 Button None Display the alarm viewer screen or return to the main
screen in a multi generator variant.
8 Status Field None Displays operational information of all components. Green
indicates OK-signals from the individual components and
red indicates missing signals.
9 Status Field None Displays the web speed in the station.
10 Status Field None Displays the selected density in Automatic (W·min/m²)-
mode or the calculated density in Power (Watt)-mode. If
W·min/m²-mode is selected and this field does not coincide
with field #1, it is either caused by the web speed being too
fast or too slow compared to the associated setup.
11 Status Field None Displays the selected Watt in Power (Watt)-mode. In
Automatic (W·min/m²)-mode the field displays how much
power is needed to produce the selected density.
12 Button None Navigates to the Trend Screen.
13 Button None Navigates to the Menu Screen.
14 Button None Engage or disengage the nip roller. In the disengaged state
the button will be white. (Optional)
15 Button None Activate or deactivate the blower relay on the generator
manually. In the activated state the button is white.
(Optional)

® Vetaphone June 2018 Page 5 of 13


4.2 TREND SCREEN:

The trend screen will continuously present the last 10 minutes of data on power (Watt) or density
(W·min/m²) and is able to show a selected time range. The data will be logged with 1-minute
interval and the database will hold 2000 data entries. The data will only be recorded on change,
and the size of the database will ensure at least 24 hours of data history even if the data changes
consistently. If the limit is reached the oldest entries will be deleted first.

2
3

# Action User level Description


1 Button None Change the display from Watt to W·min/m².
2 Button None Display legend to describe the curves.
3 Button None Select time range to view.
4 Button None Navigate back to previous screen.
5 Status Field None Displays the logged data of either Watt or W·min/m² from the
generator. Click on the Graph to return from historical mode
to live view.

® Vetaphone June 2018 Page 6 of 13


4.3 USER MENU SCREEN:

The Setup screen is intended to do corrections by initiated personnel. The information is read only
until the operator has logged in. The information and settings should not be changed during
production so it is primarily designed to give a quick overview.

7
8
9
10
11
1
12
2 13
3
4 14
5 15

# Action User level Description


1 Button None Activate or deactivate the HA-Switch. The active state is
indicated by a white button. (Optional)
2 Button Operator Navigate to the language / unit screen.
3 Button Operator Activate or deactivate wetstart. The active state is indicated
by a white button. (Optional)
4 Button Operator Navigate to the Main Screen.
5 Button None Navigate to the Alarm Viewer.
6 Status Field None Display the current version of the program running on the
iCC7.
7 Dropdown Box Operator Change the associated Generator from Power (Watt)-mode
to Automatic (W·min/m²)-mode.
8 Dropdown Box Operator Change the rotation control mode.
9 Dropdown Box Operator Change the overruling unit for the connected generator.
10 Input Field Operator Change the minimum speed required to start the generator
when the generator is in Auto or On rotational control mode.
11 Input Field Operator Change the width of the electrode.

® Vetaphone June 2018 Page 7 of 13


12 Button None Activate or deactivate HP-Switch A and HP-Switch B. The
active state is indicated by a white button. (Optional)
13 Button Operator Navigate to the Skip screen. (Optional)
14 Button None Navigate to the login screen or log out the current user.
15 Button Operator Change the time and date settings.

® Vetaphone June 2018 Page 8 of 13


4.4 ALARM VIEWER SCREEN:

The Alarm Viewer Screen will display the history of alarms and errors from the generators. It will
display the error code, timestamp and which generator had the error. Only an operator can clear
the list of alarms or get a description of the alarm.

1 3
4

# Action User Level Description


1 Status Field None Shows history of both active alarms and past alarms.
2 Button None Returns to Setup Screen.
3 Button Operator Clears history of alarms.
4 Button Operator Open a screen with a detailed description of the selected
alarm.

® Vetaphone June 2018 Page 9 of 13


4.5 LANGUAGE SCREEN
The language screen offers the possibility to change language and the units of measure. The units
of measure will change on the main screens.

# Action User Level Description


1 Dropdown Operator Change the language of the iCC7
2 Dropdown Operator Change the units of measure between imperial and metric
3 Button None Close the popup.

® Vetaphone June 2018 Page 10 of 13


5 MULTIPLE GENERATOR VARIANTS
The main screen will change if the iCC7 is used to operate multiple generators. Instead of viewing
information of a single generator it will present the most necessary things for daily operation. The
generators are separated by the gap in the middle of the screen and the identical buttons perform
identical tasks on their associated generator.

# Action User level Description


1 Button None Stop the Corona treatment. Removes errors on the
associated generator.
2 Button None Start the Corona treatment.
3 Button None Increase the Watt by 100, W·min/m² by 1, or W·min/ft² by 0.1.
4 Button None Decrease the Watt by 100, W·min/m² by 1, or W·min/ft² by
0.1.
5 Input Field None Displays the current selected power or density selected. Will
flash an error message if there an active alarm on the
generator. Click the number to directly input specific Power or
Density.
6 Button None Opens the entire station.
7 Button None Navigates to Generator 1 information Screen.
8 Button None Navigates to the Setup Screen.
9 Button None Navigates to Generator 2 information Screen.

® Vetaphone June 2018 Page 11 of 13


The user menu will display the user settings in a corresponding fashion. Otherwise the buttons
have the same functionality.

® Vetaphone June 2018 Page 12 of 13


6 TROUBLESHOOTING & REPLACEMENTS
• In case of communication error between the iCC7 and generators or other equipment, try to
power cycle every component on the communication bus. The error is diagnosed by a
warning on the screen identifying which address the iCC7 cannot get in contact with. If the
error persists through multiple power cycles contact Vetaphone Support at
Support@vetaphone.com
• In the case of the backlight failing contact Vetaphone Support. This could be diagnosed by
the blue LED shining, beeps from screen when pressing it, but nothing visible on the
screen.
• If the protective foil is damaged or otherwise obstructing the daily use, it is possible to get a
replacement from Vetaphone.
• If physically damaged and in need of replacement please contact our spare parts
department at spareparts@vetaphone.com

7 DOCUMENT REVISION
Document Revision Nr. Revision Changes
V1.0 Original Document
V1.1 V1.1 of iCC7 Software changes covered.
- Double sided variant added.
V1.2 V1.3 of iCC7 Software changes covered.
- Changes to User Menu.

® Vetaphone June 2018 Page 13 of 13