Sei sulla pagina 1di 3

K=1

Le = kL = 1(5100)
Le=5100

= 5100/200
=25.5
F’c=0.3E/SR2 = 0.3(9180)/25.52
=
4.23 MPa

CHECK FOR ALLOWABLE CAPACITY


P=F’c x A
= 4.23 x 200x200
=169.2 kN
=169.2kN> 89.64kN,,,,,,,, SAFE…

USE 200mmx200mm YAKAL FOR COLUMN


Design of Footing

I.Materials:
Compressive Strength of Concrete, f’c = 21.7MPa
Yield Strength of Steel, fy = 280MPa
Concrete Density = 23.5kN/m3
Soil Bearing Capacity, SBC = 100kPa
Concrete Cover, cc = 0.075m
Shear Reduction Factor,∅ = 0.75
Soil Depth Above Footing = 1m
Column Dimension = 0.4mx0.4m
Depth of Footing = 0.5m
Footing Bar Diameter, db = 16mm

Analysis
Area of Footing Required= Pu/ Soil Bearing Capacity,
Pu=1.2(89.64)
=107.57kN

Area of footing = 107.57kN/100KPa


=1.07m2
DIMENSION OF FOOTING= 1.5mx 1.5m
Effective Depth, ds = d - db/2 –cc
= 0.5- 0.016/2 – 0.075