Sei sulla pagina 1di 4

Contrast Penetrant Testing

NORD-TEST Cleaner U 87

Environmentally safe cleaner/remover for pre-


cleaning and removing excess surface
penetrant from an inspection area.

This class 2 non-halogenated solvent remover


can be used on a wide range of different
surfaces to remove contaminants prior to
penetrant inspection. U 87 evaporates quickly
without any residues.

Features
• AMS 2644 Class 2 non-halogenated cleaner/remover
• Available in spray cans (aerosol) or bulk
• Dries fast without leaving any residue

www.helling.de
info@helling.de
+49 (0) 4122-922-0
Specification Compliance
The NORD-TEST penetrant system has been tested and approved in accordance with

• EN ISO 3452-2
• KTA

and meets the requirements of

• Lloyd's Register of Shipping


• Bureau Veritas
• Bureau Central Hollandais
• Germanischer Lloyd
• MIL-I-25135/QPL-25135
• AMS 2644
• ASME Boiler and Pressure Vessel
• ASTM E165 und ASTM E1417

The low content of sulfur and halogens was ascertained and confirmed according to

• ASTM E 165-02 and ASTM D 516-02

as well as to requirements of

• KWU and EN ISO 3452-2

Applications
• The NORD-TEST Cleaner U 87 is being used for surface precleaning prior to
penetrant testing
• Intermediate cleaning and removal of excess penetrant
• Cleaning after penetrant inspection
• NORD-TEST Cleaner U 87 is commonly used in a variety of industries such as
general metalworking, automotive industry, shipbuilding and pressure vessels.

www.helling.de
info@helling.de
+49 (0) 4122-922-0
Further applications are:

• Welds
• Castings
• Forgings
• Pipes and tubes

Properties
Appearance Colorless liquid
Flash point in closed cup 12°C
Corrosive performance For Aluminum alloy AW 7075,
Magnesium alloy AZ-31B,
Steel 30CrMo4: No stains, pitting, signs of corrosion (at
10-fold magnification)
Sulphur content 10 ppm
Halogen content 20 ppm

User Guideline
Method Visible (red/white) penetrant testing
Usage temperature -5°C to +50°C
Penetrant NORD TEST U 88, NORD TEST Rot 3000
Developer NORD TEST U 89
Recommended test panel ASME V (part no. 127.100.000)

Directions for use


For NDT pre-cleaning:

1. Spray the surfaces to be cleaned liberally with the cleaner then either wipe off or
allow to air dry, or soak a clean cloth with the cleaner and wipe the part clean.
2. Allow the part to dry thoroughly before applying the penetrant.

www.helling.de
info@helling.de
+49 (0) 4122-922-0
To remove excess surface penetrant:

1. Apply U 87 to a cloth, wipe test surface an repeat as needed.


2. Do not spray SKC-S directly on the part because penetrant indications may be
removed.

Packaging

Spray can 500 ml Part no.121.300.101

Can 1 L Part no.121.300.102

Can 10 L Part no.121.300.103

Drum 200 L Part no.121.300.104

www.helling.de
info@helling.de
+49 (0) 4122-922-0

Potrebbero piacerti anche