46 -TG1Y (196)
SPLIT-SYSTEM
CONDENSING UNITS
10.00 SEER
HRA018 thru 060
(1.5 thru 5 Nominal Tons)
• PROTECTED COMPRESSOR - The compressor is inter- • LOW MAINTENANCE - Long life permanently lubricated
nally protected against high pressure and temperature. This motor- bearings need no annual servicing.
is accomplished by the simultaneous operation of high pres- • EASY SERVICE ACCESS - Fully exposed refrigerant con-
sure relief valve and a temperature sensor which protect the nections, a single panel covering the electrical controls and
compressor if undesirable operating conditions occur. A the molex plug in the control box connecting the condenser
liquid line filter-dryer further protects the compressor. fan, make for easy servicing of the unit.
• DURABLE FINISH - Cabinet is made of pre-painted steel. • SECURED SERVICE VALVES - Secured re-usable service
The pre-treated flat galvanized steel provides a better paint valves are provided on both the liquid and vapor sweat connec-
to steel bond, which resists corrosion and rust creep. Special tions for ease of evacuating and charging.
primer formulas and glossy earth tone finish insure less
fading when exposed to sunlight.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
TXV = Use 1TV0604 TXV kit (for 060 model start assist component not required, due to scroll compressor).
2
To meet Florida R=4.2 insulation code requirements, substitute N1FA for N2AH, N3FA for N4AH, G1FC for G3HC, F1FP for F1RP, and F1FC for F1RC
models. All ratings remain the same.
3
P2MP, P2MPV, and P2UR furnaces and F1RP / F1RC air handlers have B.O.D. standard. P1SP furnace requires B.O.D. accessory (2FD06700224).
— = Not Applicable.
SOUND RATINGS
SOUND
UNIT MODEL RATINGS
HRA BELS
H1RA UNIT
018 7.6
024 7.8 CERTIFICATION APPLIES ONLY
WHEN USED WITH PROPER
030 8.2 COMPONENTS AS LISTED WITH
ARI
036 8.2
042 8.2
048 8.2
060 8.0
COOLING PERFORMANCE
SUCT. T/P AIR TEMP ON CONDENSER SUCT. T/P AIR TEMP ON CONDENSER
MODEL @ COMPR. 75°F 95°F 115°F MODEL @ COMPR. 75°F 95°F 115°F
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
35 61.5 16.2 1.66 13.1 1.84 11.0 1.96 35 61.5 35.8 3.83 28.9 4.25 24.2 4.53
40 68.5 17.7 1.67 14.9 1.88 12.8 2.04 40 68.5 39.1 3.86 32.9 4.34 28.2 4.72
H1RA018 H1RA042
45 76.0 19.3 1.69 16.7 1.92 14.2 2.11 45 76.0 42.6 3.90 36.8 4.44 31.3 4.87
50 84.0 20.8 1.70 18.5 1.96 15.9 2.18 50 84.0 45.8 3.93 40.8 4.53 35.0 5.03
35 61.5 21.0 2.23 17.0 2.46 14.2 2.63 35 61.5 39.9 4.18 32.3 4.63 27.0 4.94
40 68.5 22.9 2.24 19.3 2.52 16.5 2.74 40 68.5 43.6 4.21 36.7 4.73 31.4 5.14
H1RA024 H1RA048
45 76.0 25.0 2.27 21.6 2.58 18.3 2.83 45 76.0 47.6 4.26 41.1 4.84 34.9 5.32
50 84.0 26.8 2.28 23.9 2.63 20.5 2.92 50 84.0 51.1 4.28 45.5 4.94 39.0 5.48
35 61.5 25.1 2.68 20.3 2.97 17.0 3.17 35 61.5 49.7 4.85 44.1 5.83 38.5 7.04
40 68.5 27.4 2.70 23.1 3.04 19.7 3.30 40 68.5 54.3 4.89 48.5 5.84 42.6 7.05
H1RA030 H1RA060
45 76.0 29.9 2.74 25.8 3.10 21.9 3.41 45 76.0 58.7 4.97 52.7 5.95 46.6 7.17
50 84.0 32.1 2.75 28.6 3.17 24.5 3.51 50 84.0 63.0 5.02 57.2 6.08 50.5 6.81
35 61.5 30.5 3.28 24.7 3.64 20.6 3.88
40 68.5 33.3 3.31 28.1 3.72 24.0 4.04
H1RA036
45 76.0 36.4 3.35 31.4 3.80 26.7 4.18
50 84.0 39.1 3.36 34.8 3.88 29.9 4.31
NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°.
Maximum recommended condensing temperature is 140°F.
DIMENSIONS
REFRIGERANT
UNIT DIMENSIONS CONNECTION
MODEL
LINE SIZE
HRA
A1 B C LIQUID VAPOR All dimensions are in inches. They are subject
018 17 35 23 5⁄ to change without notice. Certified dimensions
8 will be provided upon request.
024 17 35 23
030 17 35 23
036 19 35 23 3⁄ 3⁄
8 4
042 25 35 23
048 27 37 27 7⁄
8
060 29 37 27
1
B
Includes fan guard
C
TO FURNACE OR
18" SERVICE THERMOSTAT AIR HANDLER
ACCESS CLEARANCE TERMINAL BLOCK
60" OVERHEAD
CLEARANCE WEATHERPROOF
DISCONNECT
SWITCH NEC CLASS 1 WIRING
NEC CLASS 2 WIRING
ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
208/230-1-60 POWER
FURNACE OR AIR HANDLER CONTROL
TERMINAL BLOCK
24 VOLT FACTORY
CONTROL
C Y R G W
WIRING
CONTACTOR
TERMINALS
ACCESSORIES
Refer to Price Manual for specific model numbers. Hard Start Kit (Single Phase Units) - provides required start-
ing torque for used with thermal expansion valve.
Compressor Blanket - Designed to further reduce the normal
operating sound and is required to meet Canadian sound levels Outdoor Thermostat - 2TD06700124 - Consists of an adjust-
for units of three tons and below. able outdoor thermostat and relay in a vented enclosure. It
provides additional second stage control of the supplemental
Stub Adapters - Available to adapt sweat connect units to quick resistance heat. (balance point control)
connect coils or sweat connect coils to quick connect units.
Room Thermostats - One of the following thermostats may be
Precharged Line Sets - Available in 15, 25, 35 and 50 foot used with these systems.
lengths for connection of quick connect models. Outdoor liquid
ends have F-6 connectors, vapor ends have F-11 connectors. 2ET07700324 - Programmable electronic, One Stage Heat /
Indoor liquid ends have M-6 connectors, vapor ends have M-11 One Stage Cool, Manual change over.
connectors. All indoor vapor ends are provided with a 90° bend.
2TH07700124 - One Stage Heat / One Stage Cool, manual
A 30 foot line set with straight ends is available for splicing to
other lines for longer runs. All vapor lines are insulated with 1/2 changeover, non-programmable
sponge rubber.
Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
➀
UPFLOW
G1UA,
3 6
G3UA or
G2UT
1 4
2 5
➀
UPFLOW
M3UF
F1RP / F1RC
FAN COIL UNITS
➂
HORIZONTAL
M3HD
N1VS, N2AH
N4AH
or
N1FA, N3FA
BLOWER
➁ G3HC
DOWNFLOW or
G3CN G1FC
COIL
➃ UPFLOW ➃ UPFLOW
➅ HORIZONTAL ➄ DOWNFLOW
➁ ➅ HORIZONTAL
DOWNFLOW
G3CF