SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

HANGZHOU TDT TECHNOLOGIES CO., LTD.


Room 101, Building 3, No.12 Binwen Road
Binjiang District
Hangzhou, Zhejiang, 310051, People’s Republic of China
Bing Cai Phone: +86135-8806-0409

ELECTRICAL (EMC)

Valid To: March 31, 2021 Certificate Number: 4037.01

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following electromagnetic compatibility tests:

Test Technology: Test Method(s):

Emissions

Radiated and Conducted CFR 47, FCC Part 15 B (using ANSI C63.4:2014);
(unintentional radiators) CISPR 22; EN 55022; AS/NZS CISPR 22; GB 9254;
ICES-003; VCCI V-3 (up to 6 GHz); VCCI V-4;
CISPR 14-1 (only Radiated emissions measurements from
30 MHz to 1 GHz and conducted emissions measurements
on mains ports);
EN 55014-1 (only Radiated emissions measurements from
30 MHz to 1 GHz and conducted emissions measurements
on mains ports);
GB 4343.1 (only Radiated emissions measurements from
30 MHz to 1 GHz and conducted emissions measurements
on mains ports);
CISPR 32 (excluding CISPR 13);
EN 55032 (excluding CISPR 13);
VCCI-CISPR 32:2016; AS/NZS CISPR 32;
CISPR 15 (excluding Radiated emissions measurements
from 9 kHz to 30 MHz and insertion loss measurements);
EN 55015 (excluding Radiated emissions measurements
from 9 kHz to 30 MHz and insertion loss measurements);
GB 17743 (excluding Radiated emissions measurements
from 9 kHz to 30 MHz and insertion loss measurements)
ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-17;
CISPR 25 (excluding the whole vehicle);
GB/T 18655 (excluding the whole vehicle); GB/T 19286;
IEC 61000-6-3; EN 61000-6-3; GB 17799.3;
IEC 61000-6-4; EN 61000-6-4; GB 17799.4

(A2LA Cert. No. 4037.01) 08/13/2019 Page 1 of 4


Test Technology: Test Method(s):

Immunity

Harmonics and Flicker IEC 61000-3-2; EN 61000-3-2; GB 17625.1;


IEC 61000-3-3; EN 61000-3-3; GB 17625.2

Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; GB/T 17626.2;


CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
ISO 10605; GB/T 19951;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Continuous RF Electromagnetic IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3;


Field Disturbances CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286; ETSI EN 301 489-1;
ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Electrical Fast Transient / Burst IEC 61000-4-4; EN 61000-4-4; GB/T 17626.4;


(EFT) CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Surge Immunity IEC 61000-4-5; EN 61000-4-5; GB/T 17626.5;


CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

(A2LA Cert. No. 4037.01) 08/13/2019 Page 2 of 4


Test Technology: Test Method(s):

Immunity (cont.)

Continuous Induced RF Disturbances IEC 61000-4-6; EN 61000-4-6; GB/T 17626.6;


CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8; GB/T 17626.8;


CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Voltage Dips and Interruptions IEC 61000-4-11; EN 61000-4-11; GB/T 17626.11;


(DIP) IEC 61000-4-29; EN 61000-4-29; GB/T 17626.29;
CISPR 35; EN 55024; EN 55035; GB/T 17618;
ETSI EN 300 386; GB/T 19286;
ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 50130-4:2011+A1:2014;
IEC 61547; EN 61547; GB/T 18595;
IEC 61000-6-1; EN 61000-6-1; GB/T 17799.1;
IEC 61000-6-2; EN 61000-6-2; GB/T 17799.2

Radio ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502;
ETSI EN 300 220; ETSI EN 300 330; ETSI EN 300 440;

CFR 47, FCC Part 15, Subparts C, E


(using ANSI C63.10:2013, KDB 558074,
KDB 789033, and KDB 905462)

On the following types of equipment:


Information Technology, Multimedia and Electrical Lighting Equipment.

(A2LA Cert. No. 4037.01) 08/13/2019 Page 3 of 4


Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in
Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.1 1:

Rule Subpart/Technology Test Method Maximum


Frequency
Unintentional Radiators
Part 15B ANSI C63.4:2014 40000 MHz

Intentional Radiators
Part 15C ANSI C63.10:2013 40000 MHz

U-NII without DFS Intentional Radiators


Part 15E ANSI C63.10:2013 40000 MHz

U-NII with DFS Intentional Radiators


Part 15E FCC KDB 905462 D02 (v02) 40000 MHz

1
Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the
FCC website (https://apps.fcc.gov/oetcf/eas/) for a listing of FCC approved laboratories.

(A2LA Cert. No. 4037.01) 08/13/2019 Page 4 of 4


Accredited Laboratory
A2LA has accredited

HANGZHOU TDT TECHNOLOGIES CO., LTD.


Hangzhou, Zhejiang, People’s Republic of China
for technical competence in the field of

Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

Presented this 13th day of August 2019.

_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4037.01
Valid to March 31, 2021

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.