Sei sulla pagina 1di 20

PROJECT - DOCUMENTATION

STATION PLANNING

COLTEL DWDM-ASBUILT
PELU - 2

Telefonica Colombia
December 2017
Table of Contents

1. Site Layout

2. Rack Layout

3. Slot Assignment

4. Cabling Plan

5. Electrical Cable Laying List

6. Distributor Assignment Signaling

7. Distributor Assignment - Optical Connection

© Coriant December 2017


1. Site Layout

© Coriant December 2017


2. Rack Layout

© Coriant December 2017


3. Slot Assignment
Line
NE Shelf type Shelf ID Slot Card Directio Work order
n
Pelu-2 ONN-X SRS-1 ETSI SR ID# 001 001 MCP4-1 1 Default Work Order
004 LALPC-1 1 Default Work Order
005 PL-1 1 Default Work Order
007 LALBC-1 1 Default Work Order
010 F09DR80-1 1 Default Work Order
013 F09MR80-1 1 Default Work Order
014 LASBC-1 1 Default Work Order
016 CCEP-2 1 Default Work Order
SRS-1 ETSI SR ID# 002 003 F09DR80-1 2 Default Work Order
006 F09MR80-1 2 Default Work Order
007 MCP4-1 2 Default Work Order
008 O03CP-1 All Default Work Order
011 LALPC-1 2 Default Work Order
012 PL-1 2 Default Work Order
014 LALBC-1 2 Default Work Order
015 LASBC-1 2 Default Work Order
016 CCSP-1 2 Default Work Order
SRS-1 ETSI SR ID# 003 002 F40-1/S 1 Default Work Order
004 F40-1/S 1 Default Work Order
005 I05AD10G-1 2 Default Work Order
006 I01T10G-1/LH 1 Default Work Order
007 LASBC-1 1 Default Work Order
008 I01T10G-1/LH 1 Default Work Order
009 I01T10G-1/LH 1 Default Work Order
011 F40-1/O 1 Default Work Order
013 I01T10G-1/LH 1 Default Work Order
014 I01T10G-1/LH 1 Default Work Order
015 I01T10G-1/LH 1 Default Work Order
016 CCSP-1 1 Default Work Order
SRS-1 ETSI SR ID# 004 002 F40-1/S 2 Default Work Order
004 F40-1/S 2 Default Work Order
006 I01T10G-1/LH 2 Default Work Order
007 I01T10G-1/LH 2 Default Work Order
008 I01T10G-1/LH 2 Default Work Order
009 I01T10G-1/LH 2 Default Work Order
010 I01T10G-1/LH 2 Default Work Order
011 I01T10G-1/LH 2 Default Work Order
012 I01T10G-1/LH 2 Default Work Order
013 I01T10G-1/LH 2 Default Work Order
014 O03CP-1 All Default Work Order
015 O03CP-1 All Default Work Order
016 CCSP-1 2 Default Work Order
SRS-1 ETSI SR ID# 005 001 I01T10G-1/LH 2 Default Work Order
002 I01T10G-1/LH 1 Default Work Order
003 I01T10G-1/LH 1 Default Work Order
004 I01T10G-1/LH 2 Default Work Order
005 I01T10G-1/LH 1 Default Work Order
006 I01T10G-1/LH 2 Default Work Order
007 I01T10G-1/LH 1 Default Work Order
008 I01T10G-1/LH 2 Default Work Order
009 I01T10G-1/LH 1 Default Work Order
010 I01T10G-1/LH 2 Default Work Order
011 I01T10G-1/LH 1 Default Work Order
012 I01T10G-1/LH 2 Default Work Order
013 I01T10G-1/LH 1 Default Work Order
014 I01T10G-1/LH 2 Default Work Order
015 I01T10G-1/LH 2 Default Work Order
016 CCSP-1 2 Default Work Order
SRS-1 ETSI SR ID# 006 001 I01T10G-1/LH 1 Default Work Order

© Coriant December 2017


Line
NE Shelf type Shelf ID Slot Card Directio Work order
n
002 I01T10G-1/LH 2 Default Work Order
003 I01T10G-1/LH 1 Default Work Order
004 I01T10G-1/LH 2 Default Work Order
005 I01T10G-1/LH 2 Default Work Order
007 I01T10G-1/LH 1 Default Work Order
008 I01T10G-1/LH 2 Default Work Order
011 I01T10G-1/LH 1 Default Work Order
012 I01T10G-1/LH 2 Default Work Order
013 I01T10G-1/LH 2 Default Work Order
014 I01T10G-1/LH 1 Default Work Order
015 O03CP-1 All Default Work Order
016 CCSP-1 2 Default Work Order
SRS-1 ETSI SR ID# 007 001 I01T10G-1/LH 1 Default Work Order
002 I01T10G-1/LH 2 Default Work Order
003 I01T10G-1/LH 1 Default Work Order
004 I01T10G-1/LH 2 Default Work Order
005 I01T10G-1/LH 2 Default Work Order
006 I01T10G-1/LH 1 Default Work Order
012 F40-1/O 1 Default Work Order
013 I01T10G-1/LH 1 Default Work Order
014 I01T10G-1/LH 2 Default Work Order
016 CCSP-1 2 Default Work Order
SRS-1 ETSI SR ID# 008 001 I01T10G-1/LH 1 Default Work Order
002 I01T10G-1/LH 2 Default Work Order
016 CCSP-1 2 Default Work Order
Transponder Port Frequenc Pluggabl Tributary interface Client Mode Part Number Work order
y e type
Module
I05AD10G-1 (shelf 3, Line 1 CID 41 XFP DWDM XFP C-tunable OTU2 V50017-U790- Default Work Order
slot 005) (194.10) APD K500
I05AD10G-1 (shelf 3, Line 2 CID 45 XFP DWDM XFP C-tunable OTU2 V50017-U790- Default Work Order
slot 005) (193.90) APD K500
I01T10G-1/LH (shelf 3, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 006) OPU1e) K500
I01T10G-1/LH (shelf 3, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 008) K500
I01T10G-1/LH (shelf 3, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 009) K500
I01T10G-1/LH (shelf 3, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 013) K500
I01T10G-1/LH (shelf 3, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 014) OPU1e) K500
I01T10G-1/LH (shelf 3, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 015) K500
I01T10G-1/LH (shelf 4, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 006) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 007) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 008) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 009) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 010) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 011) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 012) OPU1e) K500
I01T10G-1/LH (shelf 4, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 013) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 001) OPU1e) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 002) OPU1e) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 003) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 004) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 005) OPU1e) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 006) OPU1e) K500
I01T10G-1/LH (shelf 5, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 007) K500
I01T10G-1/LH (shelf 5, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 008) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 009) K500

© Coriant December 2017


Line
NE Shelf type Shelf ID Slot Card Directio Work order
n
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 010) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 011) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 012) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 013) K500
I01T10G-1/LH (shelf 5, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 014) K500
I01T10G-1/LH (shelf 5, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 015) K500
I01T10G-1/LH (shelf 6, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 001) K500
I01T10G-1/LH (shelf 6, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 002) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 003) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 004) K500
I01T10G-1/LH (shelf 6, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 005) K500
I01T10G-1/LH (shelf 6, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 007) K500
I01T10G-1/LH (shelf 6, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 008) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 011) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 012) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 013) OPU1e) K500
I01T10G-1/LH (shelf 6, Client -- XFP 10GbE-S (0.3 km) 10GbE(Mapping: V50017-U773- Default Work Order
slot 014) OPU1e) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-S (0.3 km) 10GbE(Mapping: V50017-U773- Default Work Order
slot 001) OPU1e) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 002) OPU1e) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 003) OPU1e) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-L (10 km) 10GbE(Mapping: V50017-U770- Default Work Order
slot 004) OPU1e) K500
I01T10G-1/LH (shelf 7, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 005) K500
I01T10G-1/LH (shelf 7, Client -- XFP I-64.1 (2 km) STM-64 V50017-U770- Default Work Order
slot 006) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 013) K500
I01T10G-1/LH (shelf 7, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 014) K500
I01T10G-1/LH (shelf 8, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 001) K500
I01T10G-1/LH (shelf 8, Client -- XFP 10GbE-L (10 km) 10 GbE LAN V50017-U770- Default Work Order
slot 002) K500

© Coriant December 2017


4. Cabling Plan
Connect one end of the fiber here Connect other end of the fiber here

# Shelf 1) Slo Card Connector Shelf 1) Slo Card Connector Use Attenuat
t t Length or
0 Barranquilla 01 LALBC-1 OUT 1 00 LALPC-1 IN
ONN-X 3 4 4
1 1 00 LALPC-1 To ISD 1 00 LALPC-1 From ISD 3.0m 4dB
4 4
2 1 00 LALPC-1 MonSo 1 00 MCP4-1 MonP1 3.0m 3dB
4 1
3 1 00 LALPC-1 OUT 1 01 F09DR80-1 RX-IN 3.0m
4 0
4 1 01 F09DR80-1 OUT1 1 01 LASBC-1 IN 3.0m 3dB
0 4
5 1 01 F09DR80-1 OUT2 3 00 LASBC-1 IN 3.0m 3dB
0 7
6 1 01 LASBC-1 OUT 3 00 F40-1/S COM 3.0m 4dB
4 2
7 3 00 LASBC-1 OUT 3 01 F40-1/O COM 3.0m 4dB
7 1
8 1 01 LASBC-1 MonSo 1 00 MCP4-1 MonP3 3.0m
4 1
9 3 00 LASBC-1 MonSo 1 00 MCP4-1 MonP4 3.0m
7 1
10 3 00 F40-1/S COM 1 01 F09MR80-1 IN1 3.0m
4 3
11 7 01 F40-1/O COM 1 01 F09MR80-1 IN2 6.0m
2 3
12 1 01 F09MR80-1 TX-OUT 1 00 LALBC-1 IN 3.0m 2dB
3 7
13 1 01 F09DR80-1 OUT3 2 00 F09MR80-1 IN3 3.0m
0 6
14 3 00 F40-1/S 194.6 5 00 I01T10G-1/LH Line Rx 6.0m
2 7
15 3 00 F40-1/S 195.9 6 01 I01T10G-1/LH Line Rx 10.0
2 4 m
16 3 00 F40-1/S 194.2 3 00 I01T10G-1/LH Line Rx 3.0m
2 8
17 3 00 F40-1/S 193.9 6 00 I01T10G-1/LH Line Rx 10.0
2 3 m
18 6 00 I01T10G-1/LH Client Tx 4 01 O03CP-1 Working 1 3.0m
3 4 IN
19 3 00 F40-1/S 194.1 3 00 I05AD10G-1 Line Rx 1 3.0m 5dB
2 5
20 3 00 F40-1/S 194.3 5 00 I01T10G-1/LH Line Rx 6.0m
2 3
21 5 00 I01T10G-1/LH Client Tx 4 01 O03CP-1 Working 2 3.0m
3 4 IN
22 3 00 F40-1/S 195.8 8 00 I01T10G-1/LH Line Rx 10.0
2 1 m
23 8 00 I01T10G-1/LH Client Tx 6 01 O03CP-1 Working 2 6.0m
1 5 IN
24 3 01 F40-1/O 195.75 3 00 I01T10G-1/LH Line Rx 3.0m
1 6
25 3 01 F40-1/O 195.85 5 00 I01T10G-1/LH Line Rx 6.0m
1 2
26 3 00 F40-1/S 194.0 3 00 I01T10G-1/LH Line Rx 3.0m
2 9
27 3 00 F40-1/S 193.1 5 01 I01T10G-1/LH Line Rx 6.0m
2 1
28 5 01 I01T10G-1/LH Client Tx 4 01 O03CP-1 Working 3 3.0m
1 4 IN
29 3 00 F40-1/S 192.8 3 01 I01T10G-1/LH Line Rx 3.0m
2 3
30 3 00 F40-1/S 195.6 7 00 I01T10G-1/LH Line Rx 6.0m
2 3
31 3 00 F40-1/S 192.9 7 01 I01T10G-1/LH Line Rx 6.0m
2 3
32 7 01 I01T10G-1/LH Client Tx 6 01 O03CP-1 Working 1 6.0m
3 5 IN
© Coriant December 2017
Connect one end of the fiber here Connect other end of the fiber here
33 3 00 F40-1/S 193.3 5 00 I01T10G-1/LH Line Rx 6.0m
2 9
34 5 00 I01T10G-1/LH Client Tx 4 01 O03CP-1 Working 1 3.0m
9 5 IN
35 3 00 F40-1/S 193.0 5 01 I01T10G-1/LH Line Rx 6.0m
2 3
36 5 01 I01T10G-1/LH Client Tx 4 01 O03CP-1 Working 2 3.0m
3 5 IN
37 3 00 F40-1/S 193.4 6 01 I01T10G-1/LH Line Rx 10.0
2 1 m
38 6 01 I01T10G-1/LH Client Tx 2 00 O03CP-1 Working 2 6.0m
1 8 IN
39 3 00 F40-1/S 195.7 7 00 I01T10G-1/LH Line Rx 6.0m
2 6
40 3 00 F40-1/S 194.4 5 00 I01T10G-1/LH Line Rx 6.0m
2 5
41 3 00 F40-1/S 195.1 6 00 I01T10G-1/LH Line Rx 10.0
2 1 m
42 3 00 F40-1/S 193.5 6 00 I01T10G-1/LH Line Rx 10.0
2 7 m
43 6 00 I01T10G-1/LH Client Tx 2 00 O03CP-1 Working 1 6.0m
7 8 IN
44 3 00 F40-1/S 196.0 7 00 I01T10G-1/LH Line Rx 6.0m
2 1
45 3 00 F40-1/S 193.8 3 01 I01T10G-1/LH Line Rx 3.0m
2 4
46 3 00 F40-1/S 193.2 3 01 I01T10G-1/LH Line Rx 3.0m
2 5
47 6 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 195.1 10.0
1 4 m
48 3 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.2 3.0m
5 4
49 3 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 194.0 3.0m
9 4
50 6 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 195.9 10.0
4 4 m
51 2 00 O03CP-1 Working 2 6 01 I01T10G-1/LH Client Rx 6.0m
8 OUT 1
52 6 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.4 10.0
1 4 m
53 7 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 195.6 6.0m
3 4
54 4 01 O03CP-1 Working 1 6 00 I01T10G-1/LH Client Rx 3.0m
4 OUT 3
55 6 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.9 10.0
3 4 m
56 7 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 195.7 6.0m
6 4
57 4 01 O03CP-1 Working 2 5 01 I01T10G-1/LH Client Rx 3.0m
5 OUT 3
58 5 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.0 6.0m
3 4
59 6 01 O03CP-1 Working 2 8 00 I01T10G-1/LH Client Rx 6.0m
5 OUT 1
60 8 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 195.8 10.0
1 4 m
61 4 01 O03CP-1 Working 2 5 00 I01T10G-1/LH Client Rx 3.0m
4 OUT 3
62 5 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 194.3 6.0m
3 4
63 4 01 O03CP-1 Working 3 5 01 I01T10G-1/LH Client Rx 3.0m
4 OUT 1
64 5 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.1 6.0m
1 4
65 5 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 194.6 6.0m
7 4
66 3 00 I01T10G-1/LH Line Tx 7 01 F40-1/O 195.75 6.0m
6 2
67 4 01 O03CP-1 Working 1 5 00 I01T10G-1/LH Client Rx 3.0m
5 OUT 9
68 5 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.3 6.0m
9 4
69 3 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 192.8 3.0m
3 4
70 2 00 O03CP-1 Working 1 6 00 I01T10G-1/LH Client Rx 6.0m
8 OUT 7
71 6 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.5 10.0

© Coriant December 2017


Connect one end of the fiber here Connect other end of the fiber here
7 4 m
72 7 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 196.0 6.0m
1 4
73 5 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 194.4 6.0m
5 4
74 3 00 I05AD10G-1 Line Tx 1 3 00 F40-1/S 194.1 3.0m
5 4
75 6 01 O03CP-1 Working 1 7 01 I01T10G-1/LH Client Rx 6.0m
5 OUT 3
76 7 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 192.9 6.0m
3 4
77 3 01 I01T10G-1/LH Line Tx 3 00 F40-1/S 193.8 3.0m
4 4
78 3 00 I01T10G-1/LH Line Tx 3 00 F40-1/S 194.2 3.0m
8 4
79 5 00 I01T10G-1/LH Line Tx 7 01 F40-1/O 195.85 6.0m
2 2
80 3 01 F40-1/O 194.15 Pelu ONN-I 00 I01T10G-1/LH Client Rx
1 3 3
81 Pelu ONN-I 3 00 I01T10G-1/LH Client Tx 7 01 F40-1/O 194.15
3 2
82 1 00 LALBC-1 To ISD 1 00 LALBC-1 From ISD 3.0m 4dB
7 7
83 1 00 PL-1 PUMP_OUT 1 00 LALBC-1 PUMP_IN 3.0m
5 7
84 1 00 LALBC-1 MonSo 1 00 MCP4-1 MonP2 3.0m 6dB
7 1
85 1 00 LALBC-1 OUT Barranquill 01 LALPC-1 IN 7dB
7 a ONN-X 3 1
86 Barranquilla 00 LALBC-1 OUT 2 01 LALPC-1 IN
ONN-X 4 6 1
87 2 01 LALPC-1 To ISD 2 01 LALPC-1 From ISD 3.0m 4dB
1 1
88 2 01 LALPC-1 MonSo 2 00 MCP4-1 MonP3 3.0m 3dB
1 7
89 2 01 LALPC-1 OUT 2 00 F09DR80-1 RX-IN 3.0m
1 3
90 2 00 F09DR80-1 OUT1 2 01 LASBC-1 IN 3.0m 3dB
3 5
91 2 01 LASBC-1 OUT 4 00 F40-1/S COM 6.0m 4dB
5 2
92 2 01 LASBC-1 MonSo 2 00 MCP4-1 MonP1 3.0m
5 7
93 4 00 F40-1/S COM 2 00 F09MR80-1 IN1 6.0m
4 6
94 2 00 F09MR80-1 TX-OUT 2 01 LALBC-1 IN 3.0m 2dB
6 4
95 2 00 F09DR80-1 OUT3 1 01 F09MR80-1 IN3 3.0m
3 3
96 4 00 F40-1/S 194.6 5 00 I01T10G-1/LH Line Rx 3.0m
2 1
97 4 00 F40-1/S 195.6 6 01 I01T10G-1/LH Line Rx 3.0m
2 3
98 4 00 F40-1/S 194.3 5 00 I01T10G-1/LH Line Rx 3.0m
2 4
99 5 00 I01T10G-1/LH Client Tx 4 01 O03CP-1 Protection 3.0m
4 4 2 IN
10 4 00 F40-1/S 194.1 4 00 I01T10G-1/LH Line Rx 3.0m
0 2 8
10 4 00 F40-1/S 194.2 6 01 I01T10G-1/LH Line Rx 3.0m
1 2 2
10 6 01 I01T10G-1/LH Client Tx 2 00 O03CP-1 Protection 6.0m
2 2 8 2 IN
10 4 00 F40-1/S 194.8 4 01 I01T10G-1/LH Line Rx 3.0m
3 2 2
10 4 00 F40-1/S 195.5 7 00 I01T10G-1/LH Line Rx 6.0m
4 2 4
10 4 00 F40-1/S 194.9 5 00 I01T10G-1/LH Line Rx 3.0m
5 2 8
10 4 00 F40-1/S 193.7 4 00 I01T10G-1/LH Line Rx 3.0m
6 2 9
10 4 00 F40-1/S 195.3 7 00 I01T10G-1/LH Line Rx 6.0m
7 2 2
10 4 00 F40-1/S 192.1 4 01 I01T10G-1/LH Line Rx 3.0m
8 2 0
10 4 00 F40-1/S 194.7 6 00 I01T10G-1/LH Line Rx 3.0m
9 2 2

© Coriant December 2017


Connect one end of the fiber here Connect other end of the fiber here
11 4 00 F40-1/S 193.8 5 01 I01T10G-1/LH Line Rx 3.0m
0 2 0
11 5 01 I01T10G-1/LH Client Tx 4 01 O03CP-1 Protection 3.0m
1 0 5 1 IN
11 4 00 F40-1/S 192.3 4 01 I01T10G-1/LH Line Rx 3.0m
2 2 1
11 4 00 F40-1/S 193.9 3 00 I05AD10G-1 Line Rx 2 6.0m 5dB
3 2 5
11 4 00 F40-1/S 192.7 5 00 I01T10G-1/LH Line Rx 3.0m
4 2 6
11 4 00 F40-1/S 194.0 6 00 I01T10G-1/LH Line Rx 3.0m
5 2 5
11 4 00 F40-1/S 192.8 4 00 I01T10G-1/LH Line Rx 3.0m
6 2 6
11 4 00 F40-1/S 193.2 4 01 I01T10G-1/LH Line Rx 3.0m
7 2 3
11 4 00 F40-1/S 195.0 4 00 I01T10G-1/LH Line Rx 3.0m
8 2 7
11 4 00 F40-1/S 195.7 7 00 I01T10G-1/LH Line Rx 6.0m
9 2 5
12 4 00 F40-1/S 193.1 5 01 I01T10G-1/LH Line Rx 3.0m
0 2 2
12 5 01 I01T10G-1/LH Client Tx 4 01 O03CP-1 Protection 3.0m
1 2 4 3 IN
12 4 00 F40-1/S 193.4 5 01 I01T10G-1/LH Line Rx 3.0m
2 2 5
12 4 00 F40-1/S 193.0 5 01 I01T10G-1/LH Line Rx 3.0m
3 2 4
12 5 01 I01T10G-1/LH Client Tx 4 01 O03CP-1 Protection 3.0m
4 4 5 2 IN
12 4 00 F40-1/S 193.3 7 01 I01T10G-1/LH Line Rx 6.0m
5 2 4
12 7 01 I01T10G-1/LH Client Tx 6 01 O03CP-1 Protection 6.0m
6 4 5 1 IN
12 4 00 F40-1/S 192.9 6 00 I01T10G-1/LH Line Rx 3.0m
7 2 4
12 6 00 I01T10G-1/LH Client Tx 4 01 O03CP-1 Protection 3.0m
8 4 4 1 IN
12 4 00 F40-1/S 194.4 6 00 I01T10G-1/LH Line Rx 3.0m
9 2 8
13 6 00 I01T10G-1/LH Client Tx 2 00 O03CP-1 Protection 6.0m
0 8 8 1 IN
13 4 00 F40-1/S 195.8 8 00 I01T10G-1/LH Line Rx 6.0m
1 2 2
13 8 00 I01T10G-1/LH Client Tx 6 01 O03CP-1 Protection 6.0m
2 2 5 2 IN
13 4 01 O03CP-1 Protection 5 01 I01T10G-1/LH Client Rx 3.0m
3 5 2 OUT 4
13 5 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.0 3.0m
4 4 4
13 4 01 O03CP-1 Protection 5 00 I01T10G-1/LH Client Rx 3.0m
5 4 2 OUT 4
13 5 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.3 3.0m
6 4 4
13 2 00 O03CP-1 Protection 6 00 I01T10G-1/LH Client Rx 6.0m
7 8 1 OUT 8
13 6 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.4 3.0m
8 8 4
13 6 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.7 3.0m
9 2 4
14 4 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 192.8 3.0m
0 6 4
14 4 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.2 3.0m
1 3 4
14 5 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.9 3.0m
2 8 4
14 5 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 192.7 3.0m
3 6 4
14 4 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.0 3.0m
4 7 4
14 6 01 O03CP-1 Protection 8 00 I01T10G-1/LH Client Rx 6.0m
5 5 2 OUT 2
14 8 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.8 6.0m
6 2 4
14 4 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 192.1 3.0m
7 0 4
14 6 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.0 3.0m

© Coriant December 2017


Connect one end of the fiber here Connect other end of the fiber here
8 5 4
14 2 00 O03CP-1 Protection 6 01 I01T10G-1/LH Client Rx 6.0m
9 8 2 OUT 2
15 6 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.2 3.0m
0 2 4
15 4 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.8 3.0m
1 2 4
15 6 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.6 3.0m
2 3 4
15 4 01 O03CP-1 Protection 5 01 I01T10G-1/LH Client Rx 3.0m
3 5 1 OUT 0
15 5 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.8 3.0m
4 0 4
15 6 01 O03CP-1 Protection 7 01 I01T10G-1/LH Client Rx 6.0m
5 5 1 OUT 4
15 7 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.3 6.0m
6 4 4
15 5 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.6 3.0m
7 1 4
15 4 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 192.3 3.0m
8 1 4
15 4 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.7 3.0m
9 9 4
16 3 00 I05AD10G-1 Line Tx 2 4 00 F40-1/S 193.9 6.0m
0 5 4
16 4 01 O03CP-1 Protection 6 00 I01T10G-1/LH Client Rx 3.0m
1 4 1 OUT 4
16 6 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 192.9 3.0m
2 4 4
16 7 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.7 6.0m
3 5 4
16 7 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.5 6.0m
4 4 4
16 4 01 O03CP-1 Protection 5 01 I01T10G-1/LH Client Rx 3.0m
5 4 3 OUT 2
16 5 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.1 3.0m
6 2 4
16 7 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 195.3 6.0m
7 2 4
16 5 01 I01T10G-1/LH Line Tx 4 00 F40-1/S 193.4 3.0m
8 5 4
16 4 00 I01T10G-1/LH Line Tx 4 00 F40-1/S 194.1 3.0m
9 8 4
17 2 01 LALBC-1 To ISD 2 01 LALBC-1 From ISD 3.0m 4dB
0 4 4
17 2 01 PL-1 PUMP_OUT 2 01 LALBC-1 PUMP_IN 3.0m
1 2 4
17 2 01 LALBC-1 MonSo 2 00 MCP4-1 MonP4 3.0m 6dB
2 4 7
17 2 01 LALBC-1 OUT Barranquill 00 LALPC-1 IN 8dB
3 4 a ONN-X 4 4

Note: Cells with green color represent a card from a different Site.
Note: Cells with yellow color represent a card from a different Node within the same Site.
1) Connections to/from different Sites/Nodes are prefixed with the Site/Node name and NE Type.

© Coriant December 2017


5. Electrical Cable Laying List
Type Port Destination
Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          
S01 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S02 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S02 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S03 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S03 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S04 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S04 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S05 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S05 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S06 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S06 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S07 / ILAN1

Internal LAN shelf connection C39195-Z75-A1 RJ45 Cable 1:1          


S07 /116/ILAN2 ILAN 10/100BaseT, RJ45   HIT7300 ETSI S08 / ILAN1

TIF Port V42255-Z1001-A5 S-09YS(St)CY 8x2x0,6/1,2          


S01   Telemetry Interface COPA (TIF) TIF MDF 1 / 01_02
 
EOW Port V42255-Z1001-A5 S-09YS(St)CY 3x2x0,6/1,2          
S01   EOW (MSI) COPA (EOW) EOW MDF 1 / 3

© Coriant December 2017


6. Distributor Assignment Signaling
Distributo Pi Colour/ Connected Cable Colour/ Con. Port Equipment
r n Con.
/ 1 a 1a WH/BU TIF - S-09YS(St)CY 8x2x0.6/1.2 1a WH/BU TIFIN1 (1) CP-TIF-in HIT7300 / S01
01 ETSI
    b 1b WH/BU   1b WH/BU TIFIN2 (2)    
  2 a 2a WH/BU   2a WH/BU TIFIN3 (3)    
    b 2b WH/YE   2b WH/YE TIFIN4 (4)    
  3 a 3a WH/BU   3a WH/BU TIFIN5 (5)    
    b 3b WH/GN   3b WH/GN TIFIN6 (6)    
  4 a 4a WH/BU   4a WH/BU TIFIN7 (7)    
    b 4b WH/BN   4b WH/BN TIFIN8 (8)    
  5 a 5a WH/BU   5a WH/BU TIFIN9 (9)    
    b 5b WH/BK   5b WH/BK TIFIN10 (10)    
  6 a 6a WH/YE   6a WH/YE TIFIN11 (11)    
    b 6b WH/BU   6b WH/BU TIFIN12 (12)    
  7 a 7a WH/YE   7a WH/YE TIFIN13 (13)    
    b 7b WH/YE   7b WH/YE TIFIN14 (14)    
  8 a 8a WH/YE   8a WH/YE TIFIN15 (15)    
    b 8b WH/GN   8b WH/GN TIFIN16 (16)    
 
/ 1 a 9a WH/YE TIF - S-09YS(St)CY 8x2x0.6/1.2 9a WH/YE TIFCOMIN1 (17) CP-TIF-IN (cont) HIT7300 / S01
02 ETSI
    b 9b WH/BN   9b WH/BN TIFCOMIN2 (18)    
  2 a 10a WH/YE   10a WH/YE      
    b 10b WH/BK   10b      
WH/BK
  3 a 11a WH/GN   11a NUBAT (21)    
WH/GN
    b 11b WH/BU   11b      
WH/BU
  4 a 12a WH/GN   12a GND (23)    
WH/GN
    b 12b WH/YE   12b WH/YE GND (24)    
  5 a 1a WH/BU   1a WH/BU TIFO1 (1) CP-TIF-OUT  
    b 1b WH/BU   1b WH/BU TIFO2 (2)    
  6 a 2a WH/BU   2a WH/BU TIFO3 (3)    
    b 2b WH/YE   2b WH/YE TIFO4 (4)    
  7 a 3a WH/BU   3a WH/BU TIFO5 (5)    
    b 3b WH/GN   3b WH/GN TIFO6 (6)    
  8 a 4a WH/BU   4a WH/BU TIFO7 (7)    
    b 4b WH/BN   4b WH/BN TIFO8 (8)    
 
/ 1 a 5a WH/BU TIF - S-09YS(St)CY 8x2x0.6/1.2 5a WH/BU CRITAU_TIFO9_NO (9) CP-TIF-OUT (cont) HIT7300 / S01
03 ETSI
    b 5b WH/BK   5b WH/BK CRITAU_NC (10)    
  2 a 6a WH/YE   6a WH/YE MAJAU_TIFO10_NO    
(11)
    b 6b WH/BU   6b WH/BU MAJAU_NC (12)    
  3 a 7a WH/YE   7a WH/YE MINAU_TIFO11_NO    
(13)
    b 7b WH/YE   7b WH/YE MINAU_NC (14)    
  4 a 8a WH/YE   8a WH/YE TIFCOMOUT1 (15)    
    b 8b WH/GN   8b WH/GN CRITVI_TIFO12_NO    
(16)
  5 a 9a WH/YE   9a WH/YE CRITVI_NC (17)    
    b 9b WH/BN   9b WH/BN MAJVI_TIFO13_NO    
(18)
  6 a 10a WH/YE   10a WH/YE MAJVI_NC (19)    
    b 10b WH/BK   10b MINVI_TIFO14_NO    
WH/BK (20)
  7 a 11a WH/GN   11a MINVI_NC (21)    
WH/GN
    b 11b WH/BU   11b PWF_NO (22)    
WH/BU
  8 a 12a WH/GN   12a PWF_NC (23)    
WH/GN
    b 12b WH/YE   12b WH/YE ALCOM (24)    

© Coriant December 2017


 
/ 1 a 1a WH/BU EOW - S-09YS(St)CY 1a WH/BU EOW_1_PI (3) CP-EOW HIT7300 / S01
04 3x2x0.6/1.2 ETSI
    b 1b WH/BU   1b WH/BU EOW_1_NI (7)    
  2 a 2a WH/BU   2a WH/BU EOW_1_PO (5)    
    b 2b WH/YE   2b WH/YE EOW_1_NO (9)    
  3 a SHIELD   SHIELD GND (1)    

© Coriant December 2017


7.Distributor Assignment - Optical Connection
Distribut
Location Pin   Connected Cable    Equipment Direction
or

ODF FILA E2 PEL TX Optical Connection o Client S0 /115_I01T10G-


1 BAR2 (193.20)
01 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /115_I01T10G-
2 BAR2 (193.20)
01 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /113_I01T10G-
3 BAR2 (193.20)
01 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /113_I01T10G-
4 BAR2 (193.20)
01 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /115_I01T10G-
5 BORT (193.40)
01 RACK 7 2 PtoX Cable pt Tx 5 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /115_I01T10G-
6 BORT (193.40)
01 RACK 7 2 PtoX Cable pt Rx 5 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /105_I01T10G-
7 BORT (194.00)
01 RACK 7 2 PtoX Cable pt Tx 6 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /105_I01T10G-
8 BORT (194.00)
01 RACK 7 2 PtoX Cable pt Rx 6 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /113_I01T10G-
9 CAR2 (192.80)
01 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /113_I01T10G-
CAR2 (192.80)
01 0 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /108_I01T10G-
CAR2 (194.20)
01 1 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /108_I01T10G-
CAR2 (194.20)
01 2 RACK 7 2 PtoX Cable pt Rx 2 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client 7 S2 BOCE (W194.60-P192.20) W 5
/001_OSM2S
01 3 RACK 7 6 PtoX Cable pt Tx 0 101
ODF 1 FILA E2 PEL RX Optical Connection o Client 7 S2 BOCE (W194.60-P192.20) P 5 -
/001_OSM2S
01 4 RACK 7 6 PtoX Cable pt Rx 0 102
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /106_I01T10G-
BUCA (192.80)
01 5 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /106_I01T10G-
BUCA (192.80)
01 6 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /109_I01T10G-
TOLU (194.00)
01 7 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /109_I01T10G-
TOLU (194.00)
01 8 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /108_I01T10G-
BAR2 (194.10)
01 9 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF 2 FILA E2 PEL RX Optical Connection o Client S0 /108_I01T10G-
BAR2 (194.10)
01 0 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF 2 FILA E2 PEL TX Optical Connection o Client 1 S0 BOCE (W194.40-P192.70) W 5
/106_O03CP-1
01 1 RACK 7 2 PtoX Cable pt Tx 6 - 105
ODF 2 FILA E2 PEL RX Optical Connection o Client 1 S0 BOCE (W194.40-P192.70) P 5 -
/106_O03CP-1
01 2 RACK 7 2 PtoX Cable pt Rx 6 106
ODF 2 FILA E2 PEL TX Optical Connection o Client S0 /114_I01T10G-
BAR2 (193.80)
01 3 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 2 FILA E2 PEL RX Optical Connection o Client S0 /114_I01T10G-
BAR2 (193.80)
01 4 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF FILA E2 PEL TX Optical Connection o S2
1 15 Tx /003_OSM2S BOR6 (W195.10-P194.70)
02 RACK 7 6 PtoX Cable pt 0
ODF 2 FILA E2 PEL RX Optical Connection o 15 Rx S2 /003_OSM2S BOR6 (W195.10-P194.70)

© Coriant December 2017


02 RACK 7 6 PtoX Cable pt 0
ODF FILA E2 PEL
3
02 RACK 7 U
ODF FILA E2 PEL
4
02 RACK 7 U
ODF FILA E2 PEL TX Optical Connection o Client 1 S0 BAR2 (W193.90-P192.90) W 6
5 /114_O03CP-1
02 RACK 7 2 PtoX Cable pt Tx 4 - 103
ODF FILA E2 PEL RX Optical Connection o Client 1 S0 BAR2 (W193.90-P192.90) P 6 -
6 /114_O03CP-1
02 RACK 7 2 PtoX Cable pt Tx 4 104
ODF FILA E2 PEL TX Optical Connection o Client 3 S0 BAR2 (W193.10-P193.10) W 5
7 /114_O03CP-1
02 RACK 7 2 PtoX Cable pt Tx 4 - 111
ODF FILA E2 PEL RX Optical Connection o Client 3 S0 BAR2 (W193.10-P193.10) P 5 -
8 /114_O03CP-1
02 RACK 7 2 PtoX Cable pt Rx 4 112
ODF FILA E2 PEL TX Optical Connection o Client 2 S0 BAR2 (W193.00-P193.00) W 5
9 /115_O03CP-1
02 RACK 7 2 PtoX Cable pt Tx 4 - 113
ODF 1 FILA E2 PEL RX Optical Connection o Client 2 S0 BAR2 (W193.00-P193.00) P 5 -
/115_O03CP-1
02 0 RACK 7 2 PtoX Cable pt Rx 4 114
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /106_I01T10G-
SMAR (192.30)
02 1 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /106_I01T10G-
SMAR (192.30)
02 2 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /109_I01T10G-
BAR2 (193.70)
02 3 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /109_I01T10G-
BAR2 (193.70)
02 4 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /110_I01T10G-
BAR2 (192.10)
02 5 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /110_I01T10G-
BAR2 (192.10)
02 6 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /111_I01T10G-
BAR2 (192.30)
02 7 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF 1 FILA E2 PEL RX Optical Connection o Client S0 /111_I01T10G-
BAR2 (192.30)
02 8 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF 1 FILA E2 PEL TX Optical Connection o Client S0 /110_I01T10G-
BAR2 (192.90)
02 9 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 2 FILA E2 PEL RX Optical Connection o Client S0 /110_I01T10G-
BAR2 (192.90)
02 0 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF 2 FILA E2 PEL TX Optical Connection o Client S0 /112_I01T10G-
BAR2 (192.50)
02 1 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 2 FILA E2 PEL RX Optical Connection o Client S0 /112_I01T10G-
BAR2 (192.50)
02 2 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF 2 FILA E2 PEL TX Optical Connection o Client S0 /107_I01T10G-
BAR2 (193.70)
02 3 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF 2 FILA E2 PEL RX Optical Connection o Client S0 /107_I01T10G-
BAR2 (193.70)
02 4 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /111_I01T10G-
1 BAR2 (193.60)
03 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /111_I01T10G-
2 BAR2 (193.60)
03 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /107_I01T10G-
3 EWBP (195.00)
03 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /107_I01T10G-
4 EWBP (195.00)
03 RACK 7 2 PtoX Cable pt Rx 4 1/LH
ODF FILA E2 PEL TX Optical Connection o Client S0 /112_I01T10G-
5 SMAR (194.80)
03 RACK 7 2 PtoX Cable pt Tx 4 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /112_I01T10G-
6 SMAR (194.80)
03 RACK 7 2 PtoX Cable pt Rx 4 1/LH
/
ODF FILA E2 PEL TX Optical Connection o Client 1 S0
7 105_I05AD10G- PAST (W194.10-P193.90)
03 RACK 7 2 PtoX Cable pt Tx 3
1
ODF 8 FILA E2 PEL RX Optical Connection o Client 1 S0 / PAST (W194.10-P193.90)
03 RACK 7 2 PtoX Cable pt Rx 3 105_I05AD10G-

© Coriant December 2017


1
/
ODF FILA E2 PEL TX Optical Connection o Client 2 S0
9 105_I05AD10G- PAST (W193.90-P194.10)
03 RACK 7 2 PtoX Cable pt Tx 3
1
/
ODF 1 FILA E2 PEL RX Optical Connection o Client 2 S0
105_I05AD10G- PAST (W193.90-P194.10)
03 0 RACK 7 2 PtoX Cable pt Rx 3
1
ODF 1 FILA E2 PEL TX Optical Connection o S2
1 Tx /001_OSM2S TOL6 (W192.35-P193.00)
03 1 RACK 7 6 PtoX Cable pt 0
ODF 1 FILA E2 PEL RX Optical Connection o S2
1 Rx /001_OSM2S TOL6 (W192.35-P193.00)
03 2 RACK 7 6 PtoX Cable pt 0
ODF 1 FILA E2 PEL TX Optical Connection o Client 2 S0 BAR2 (W194.30-P194.30) W 5
/114_O03CP-1
03 3 RACK 7 2 PtoX Cable pt Tx 4 - 103
ODF 1 FILA E2 PEL RX Optical Connection o Client 2 S0 BARR2(W194.30-P194.30) P 5
/114_O03CP-1
03 4 RACK 7 2 PtoX Cable pt Rx 4 - 104
ODF 1 FILA E2 PEL TX Optical Connection o Client 1 S0 BAR2 (W193.30-P193.80) W 5
/115_O03CP-1
03 5 RACK 7 2 PtoX Cable pt Tx 4 - 109
ODF 1 FILA E2 PEL RX Optical Connection o Client 1 S0 BAR2 (W193.30-P193.80) P 5 -
/115_O03CP-1
03 6 RACK 7 2 PtoX Cable pt Rx 4 110
ODF 1 FILA E2 PEL TX Optical Connection o Client 1 S0 TABO (W194.00-P193.20) W 2
/105_O03CP-1
03 7 RACK 7 U PtoX Cable pt Tx 2 - 103
ODF 1 FILA E2 PEL RX Optical Connection o Client 1 S0 TABO (W194.00-P193.20) P 2
/105_O03CP-1
03 8 RACK 7 U PtoX Cable pt Rx 2 - 104
ODF 1 FILA E2 PEL TX Optical Connection o Client 2 S0 BAR2 (W193.40-P194.20) W 6
/108_O03CP-1
03 9 RACK 7 2 PtoX Cable pt Tx 2 - 111
ODF 2 FILA E2 PEL RX Optical Connection o Client 2 S0 BAR2 (W193.40-P194.20) P 6 -
/108_O03CP-1
03 0 RACK 7 2 PtoX Cable pt Rx 2 112
ODF 2 FILA E2 PEL TX Optical Connection o S2
9 Tx /003_OSM2S BOR6 (W196.00-195.30)
03 1 RACK 7 6 PtoX Cable pt 0
ODF 2 FILA E2 PEL RX Optical Connection o S2
9 Rx /003_OSM2S BOR6 (W196.00-195.30)
03 2 RACK 7 6 PtoX Cable pt 0
ODF 2 FILA E2 PEL TX Optical Connection o Client 4 S2 BOR3 (W195.60-P195.90) W -
/001_OSM2S
03 3 RACK 7 6 PtoX Cable pt Tx 0 6 - 113
ODF 2 FILA E2 PEL RX Optical Connection o Client 4 S2 BOR3 (W195.60-P195.90) P - 6
/001_OSM2S
03 4 RACK 7 6 PtoX Cable pt Rx 0 - 114
ODF FILA E2 PEL TX Optical Connection o S2
1 12 Tx /003_OSM2S BOR6 (W195.60-P195.50)
04 RACK 7 6 PtoX Cable pt 0
ODF FILA E2 PEL RX Optical Connection o S2
2 12 Rx /003_OSM2S BOR6 (W195.60-P195.50)
04 RACK 7 6 PtoX Cable pt 0
ODF FILA E2 PEL TX Optical Connection o Client 1 S0 BAR2 (W193.50-P194.40) W 6
3 /108_O03CP-1
04 RACK 7 2 PtoX Cable pt Tx 2 - 107
ODF FILA E2 PEL RX Optical Connection o Client 1 S0 BAR2 (W193.50-P194.40) P 6
4 /108_O03CP-1
04 RACK 7 2 PtoX Cable pt Rx 2 -108
ODF FILA E2 PEL TX Optical Connection o S2
5 18 Tx /003_OSM2S BOR6(W195.70-P195.70)
04 RACK 7 6 PtoX Cable pt 0
ODF FILA E2 PEL RX Optical Connection o S2
6 18 Rx /003_OSM2S BOR6(W195.70-P195.70)
04 RACK 7 6 PtoX Cable pt 0
ODF FILA E2 PEL TX Optical Connection o Client 3 S2
7 /003_OSM2S TABO (W193.90-P194.10)
04 RACK 7 6 PtoX Cable pt Tx 0
ODF FILA E2 PEL RX Optical Connection o Client 3 S2
8 /003_OSM2S TABO (W193.90-P194.10)
04 RACK 7 6 PtoX Cable pt Rx 0
ODF FILA E2 PEL TX Optical Connection o Client 6 S2
9 /003_OSM2S TABO (W193.80-P194.30)
04 RACK 7 6 PtoX Cable pt Tx 0
ODF 1 FILA E2 PEL RX Optical Connection o Client 6 S2
/003_OSM2S TABO (W193.80-P194.30)
04 0 RACK 7 6 PtoX Cable pt Rx 0
ODF 1 FILA E2 PEL TX Optical Connection o Client 1 S0
/115_O03CP-1 BAR2 (W192.90-P193.30)
04 1 RACK 7 6 PtoX Cable pt Tx 6
ODF 1 FILA E2 PEL RX Optical Connection o Client 1 S0
/115_O03CP-1 BAR2 (W192.90-P193.30)
04 2 RACK 7 6 PtoX Cable pt Tx 6
ODF 1 FILA E2 PEL TX Optical Connection o Client 2 S0 PEL2 (W195.80-P195.80) W 8-
/115_O03CP-1
04 3 RACK 7 2 PtoX Cable pt Tx 6 101
ODF 1 FILA E2 PEL RX Optical Connection o Client 2 S0 /115_O03CP-1 PEL2 (W195.80-P195.80) P 8 -

© Coriant December 2017


04 4 RACK 7 2 PtoX Cable pt Rx 6 102
ODF 1 FILA E2
04 5 RACK 7
ODF 1 FILA E2
04 6 RACK 7
ODF 1 FILA E2
04 7 RACK 7
ODF 1 FILA E2
04 8 RACK 7
ODF 1 FILA E2
04 9 RACK 7
ODF 2 FILA E2
04 0 RACK 7
ODF 2 FILA E2
04 1 RACK 7
ODF 2 FILA E2
04 2 RACK 7
ODF 2 FILA E2
04 3 RACK 7
ODF 2 FILA E2
04 4 RACK 7
ODF FILA E2 PEL TX Optical Connection o Client S0 /112_I01T10G-
1 CHA6 (193.70)
05 RACK 7 2 PtoX Cable pt Tx 3 1/LH
ODF FILA E2 PEL RX Optical Connection o Client S0 /112_I01T10G-
2 CHA6 (193.70)
05 RACK 7 2 PtoX Cable pt Rx 3 1/LH
ODF FILA E2
3
05 RACK 7
ODF FILA E2
4
05 RACK 7
ODF FILA E2
5
05 RACK 7
ODF FILA E2
6
05 RACK 7
ODF FILA E2
7
05 RACK 7
ODF FILA E2
8
05 RACK 7
ODF FILA E2
9
05 RACK 7
ODF 1 FILA E2
05 0 RACK 7
ODF 1 FILA E2
05 1 RACK 7
ODF 1 FILA E2
05 2 RACK 7
ODF 1 FILA E2
05 3 RACK 7
ODF 1 FILA E2
05 4 RACK 7
ODF 1 FILA E2
05 5 RACK 7
ODF 1 FILA E2
05 6 RACK 7
ODF 1 FILA E2
05 7 RACK 7
ODF 1 FILA E2
05 8 RACK 7
ODF 1 FILA E2
05 9 RACK 7
ODF 2 FILA E2
05 0 RACK 7
ODF 2 FILA E2

© Coriant December 2017


05 1 RACK 7
ODF 2 FILA E2
05 2 RACK 7
ODF 2 FILA E2
05 3 RACK 7
ODF 2 FILA E2
05 4 RACK 7

© Coriant December 2017