DESIGN OF STRUCTURE

FOR
60MX16M HANGAR GATE

FABRIC HOIST UP DOOR

&SIDE COLUMN
DOCUMENT NO. HC-1814-01-R6

DEC, 2018

CLIENT:-
CPWD, NEW DLEHI

CONTRACTOR:
TEMPCON ENGINEERS
4, CENTRAL LANE BENGALI MARKET
NEW DELHI 110001
STRUCTURAL CONSULTANT:

DESIGNED BY: SUDHANSHU SHEKHAR CHECK BY: S.L.MAHAJAN

HC/ TEMPCON File: 466884463.xlsx - Sheet: Cover Status: 03/27/2020


HC/ TEMPCON File: 466884463.xlsx - Sheet: Cover Status: 03/27/2020
INTRODUCTION/ DESIGN CRITERIA Page:3 of 7

Design Criteria Designing, structure, assembling


of fabric hoist up door & side column

BMA/ ABCI/ NF Rly. File: 466884463.xlsx - Sheet: DSGN-CRIT Status: 03/27/2020


INTRODUCTION/ DESIGN CRITERIA Page:4 of 7

1.0   Codes And Standards

The structural design will basically conform to the latest revision of codes
and recommendation of INDIAN STANDARDS specifications.

For manufactured items the recommendations of manufacturer for


PROPRIETORY ITEMS regarding the use, design criteria, installation
instructions and properties will be adopted with appropriate guarantees for
performance.

  The following are the various Design Codes that shall be followed for the
structural design of the various components of structure. These shall be
supplemented, wherever required, by guidelines from various international
1.1            
codes and literature issued by different Government of India Undertakings.

Book Design of steel structures By Prof. S.Ramamrutham, published by-Dhanpat


rai publishing company

IS: 875-1987 Code of practice for Structural safety of building and loading

IS: 875(3)-2015 Code of practice for Design Loads for buildings and structures

IS: 1893; Criteria for Earthquake Resistant design of structures (Part-I).


(Part-I)-2002

IS: 456-2000 Code of practice for plain and reinforced concrete.

The following are the various Design Codes that shall be followed for
1.2  the material specification.

IS: 269-1989 Ordinary Grade Portland Cement.

IS: 2062-2006 Hot rolled Low, Medium & High tenile Structural Steel
IS: 1148-(Latest) Hot rolled steel river bar (upto 40mm dia.) for structural purpose
+A76

BMA/ ABCI/ NF Rly. File: 466884463.xlsx - Sheet: DSGN-CRIT Status: 03/27/2020


INTRODUCTION/ DESIGN CRITERIA Page:5 of 7

IS:1929-1961 Rivets for general purpose (12mm to 48mm dia.)

Rivets for general purpose ( upto 12mm dia.)


IS:2155-(Latest)
IS:814 Covered electrodes for Manual Metal Arc welding.

IS :816 Code of Practice for use of Metal Arc Welding for General Construction in
Mild Steel

IS:9103-1979 Admixture for concrete

IS:102-1962 Ready mixed paint, brushing, red lead, non-setting priming

IS:2502-1963 Code of practice for bending and fixing of bars for concrete reinforcement

IS: 9595 - 1980 Indian Standard Recommendations for Metal Arc Welding of Carbon
Manganese Steels

IS: 7215-1974 Tolerances for Fabrication of Steel Structure

IS:10262 Concrete Mix Design.

IS:800-2007 Code of practice for general construction in steel

IS:13920-2016 Code of practice for Ductile detailing of reinforced concrete structures

IS:4923-1997 Specifications of hollow steel sections for structural use

IS:4091-1979 Code of practice for design and construction of foundations for transmission
line towers and poles.

2.0  Design Standards

The following is a summary of the various Design Standards that will be


adopted for the various structural components of bridges
Design Loading
Dead Loads As per IRS Bridge Rules
Live Loads As per Door manufacturer recommended

BMA/ ABCI/ NF Rly. File: 466884463.xlsx - Sheet: DSGN-CRIT Status: 03/27/2020


INTRODUCTION/ DESIGN CRITERIA Page:6 of 7

Wind Loads. Wind pressure effect on the structure as per clause wind pressure as per IS-
875-1987.

Earthquake As per IS: 1893-2002 (Zone-IV )


Loads

Load Considered :-
Following loads have been considered while designing the structural
drawing for the Hangar Door
1. Hangar Door Weight
2. Self contained weight (weight of steel structure)
3. Wind Load
4. Temperature Rise & Fall

Material Specification:
Steel:
Structural Steel As per IS: 2062 Quality 'B' Grade designation E250 (Fe 410 W) fully
killed & normalised/ controlled cooled.

3. Welding Rod shall be used of reputed make


(Advani / Mangalam or equivalent)

4. The steel members / Plates shall be strictly as per grades


mentioned in design report. The make of Steel Shall be ISI.

5. In case the makes approved by CPWD is not available / delayed delivery


then similar make as per IS Standard (Tata Structra, APL Apollo,
Jindal, Surya etc.), duly approve by competent authority shall be used.

6. Door manufacturer recommended for 2x3 leg system structure as


per sketch attached. When the door is closed, wind load will be very
high causing appreciable foundation size. Due to large size of foundation,
it is required to keen the columns away from the existing wall and also
necessary to cover the space between door columns and existing
structure to make it waterproof and bird/ rat free, providing extra
structure to comply the requirements.
The structure designed is with 4 No column on either side without

BMA/ ABCI/ NF Rly. File: 466884463.xlsx - Sheet: DSGN-CRIT Status: 03/27/2020


INTRODUCTION/ DESIGN CRITERIA Page:7 of 7

which is may not be possible due to below mentioned reason:-


(i)   High Uplift/ downward force due to wind load on closed door;
(ii)   Proper Load transfer;
(iii)   Existing structure foundation overlapping with main load
bearing column;
(iv) Availability of space and adhering to the dimensions of door
manufacturer.
x-x-x