MAGLUMI 800

Chemiluminescence Immunoassay (CLIA) System


OUTSTANDING TECHNOLOGY
POWER OF MAGLUMI
Chemiluminescence Immunoassay (CLIA) System
CLIA uses two important technologies, one is labeling technology which determines reaction mode; and the other is
separation technology which determines the sensitivity, accuracy and precision of the reagents.

Labeling Technology Separation Technology

Two types of labeling technologies are commonly used. Maglumi uses Magnetic Microbeads. As separation
One is enzyme label and the other is non-enzyme samll technology, it has been widely used in the field of CLIA.
molecule label. Enzyme label reagents are not so stable Compared with traditional separation technology, it has
and are easily effected by the change of storage the following advantages:
conditions. Maglumi system applies ABEI labels. ABEI ƔShortening the reaction time by enlarging the reaction
is a non-enzyme samll molecule with special molecular
formula to enhance stability in acid and alkaline solution. Ɣarea of antigens and antibodies.
As fast chemiluminescence, ABEI chemical reaction ƔEnhancing the sensitivity by better and faster capture
with sodium hydroxide (NaOH) and Hyperoxide (H2O2) of antigens and antibodies.
finishes the process in 3 seconds. ƔReducing inter or intra-assay discrepancies
significantly by mixing the reagents thoroughly in a
liquid separation platform.
ƔEnhancing the accuracy by absorbing antigens and
antibodies through chemical reaction.
ADVANTAGE
OF MAGLUMI 800

Ɣ)RUVPDOODQGPLGGOHVL]HODEVRUKRVSLWDOV
Ɣ6LPSOH6PDUW+XPDQL]DWLRQGHVLJQHGPRGHO
Ɣ 0RUH WKDQ HQRXJK WHVW PHQX WR PHHW WKH GLIIHUHQW
needs and it is enlarging according to your requirement
Ɣ)UHH4XDOLW\&RQWURODQGFDOLEUDWRUKHOSVWRUHGXFHWKH
Cost Per Test
56cm
Ɣ 4XDOLW\ JXDUDQWHH E\ WKH 7KLUG SDUW\ TXDOLW\ FRQWURO
DQG([WHUQDO4XDOLW\$VVHVVPHQW (4$
Ɣ.H\WHFKQRORJ\$%(,DQG1DQRPDJQHWLFPLFUREHDG
enhances stability and sensitivity of MAGLUMI reagents
102cm 72cm
MAGLUMI 800
Ɣ,QWHJUDWHGGHVLJQDQGKXPDQL]HGDSSHDUDQFH
Ɣ6LPSOHDQGVPDUWRSHUDWLRQ
Ɣ&RPSDFWVL]HDQGZHLJKW

Chamber
Pipettor Ɣ+LJKVHQVLWLYLW\DQGORZQRLVH307
Ɣ$VSLUDWHUHDJHQWVDPSOHZLWKKLJKVSHHG
Ɣ&XYHWWHVGHWHFWLRQDQGDQWLRYHUIORZ
Ɣ7LWDQLXPQHHGOHIRUFUXVKSURRI
Ɣ&ORWGHWHFWLRQ OLTXLGOHYHOGHWHFWLRQ
Ɣ&RDWHGZLWK7()/21WRSUHYHQWFDUU\RYHU
Ɣ,QQHU H[WHUQDOZDVKLQJ

Washer
Ɣ6WURQJPDJQHWLFILHOGKHOSVEHWWHU
separation
Ɣ7KUHHSDLUVRIZDVKLQJQHHGOHVZLWK
anti-overflow function

Automated cuvette loader


ƔUp to 40 modules of 240 tests
ƔContinuous loading

Reagent area
Ɣ8SWRUHDJHQWVRQERDUGZLWK5),'
Ɣ5),'ODEHOVWRULQJUHDJHQWLQIRUPDWLRQ
Ɣ(DV\DQGIDVWIRUDGGLQJDQGXSGDWLQJ
Ɣ5),'WDJKLJKUHOLDELOLW\

Sample area Incubator


Ɣ8SWRVDPSOHRQERDUGZLWKEDUFRGH Ɣ,QFXEDWHVORWV WHVWVDWWKHVDPHWLPH 
Ɣ&RQWLQXRXVORDGLQJ FRROLQJIXQFWLRQ Ɣ7KHWHPSHUDWXUHLV℃±0.5℃
OPERATION SOFTWARE

Comprehensive software Maintenance Guide


Ɣ8VHUIULHQGO\,QWHUIDFH Ɣ'DLO\ZHHNO\DQGPRQWKO\PDLQWHQDQFH
Ɣ5HDOWLPHVWDWXVPRQLWRULQJIRUHDFKWHVW guide for analytical unit
Ɣ0RQLWRULQJUHDJHQWDQGFRQVXPDEOHVWDWXV ƔEnsure performance reliability and reduce
Ɣ,QWHOOLJHQWDODUPIXQFWLRQ unnecessary service calls

Quality control Test Summary Function

4& Ɣ:HVWJDUGUXOHVDQG/HYH\-HQQLQJVFKDUWIRU
both internal and external quality control
ƔTest summary including system test, calibration,
4&VWDWLVWLFVRIVDPSOHVYDOLGWHVWVDQGUHUXQWHVWV
ƔSearch and review test information conveniently

Pre or post defined dilution Function Connect to LIS ( bidirection )


ƔPre or post defined dilution flexibly if high Ɣ%LGLUHFWLRQ/LVFDQFRQQHFWE\RQOLQHDQG
concentration is met ASTM
TEST MENU

Tumor Markers Fertility Hepatic Fibrosis Drug Monitoring

)HUULWLQ )6+ HA Cyclosporine A


$)3 LH PIIIP N-P 7DFUROLPXV).
CEA +&*ȕ±+&* C IV 'LJR[LQ
Total PSA PRL Laminin
f-PSA Estradiol Cholyglycine
Cardiac
CA 125 free Estriol
CA 15-3 Progesterone &.0%
&$ Testosterone TORCH Troponin I
PAP free Testosterone Toxo lgG Myoglobin
CA 50 '+($6 Toxo lgM NT-proBNP
&<)5$ *AMH Rubella lgG Aldosterone
CA 242 17-OH Progesterone Rubella lgM Angiotensin I
CA 72-4 CMV lgG Angiotensin II
NSE Thyroid CMV lgM ''LPHU
S-100 +69OJ* 'LUHFW5HQLQ
TSH
SCCA HSV-2 lgG LP-PLA2
T4
TPA-snibe +69OJ0 hs-cTnl
T3
Pepsinogen I
)7
Pepsinogen II
)7 Infectious Disease
Gastrin-17 EBV
TG HBsAg
H.pylori IgG
TGA EBV EA lgG Anti-HBs
TRAb EBV EA lgA HBeAg
TMA EBV VCA lgG Anti-HBe
Anti-TPO EBV VCA lgM Anti-HBc
Bone Metabolism Rev T3 EBV VCA lgA Anti-HCV
Intact PTH EBV NA lgG Syphilis
Prenatal Screening Chagas
Calcitonin
Osteocalcin +7/9,,,
F$)3
2+9LWDPLQ' Immunoglobulin Anti-HAV
IUHHȕ±+&*
HAV IgM
PAPP-A lgM
HIV A b
lgA
Inflammation HIV p24 Ag
Glyco Metabolism lgE
Monitoring +,9$E$JFRPEL
lgG
C-Peptide
Insulin CRP
ICA
Others
PCT
Anemia
IAA GH
Proinsulin Kidney Function Vitamin B12 ,*),
*$' ȕ0* )HUULWLQ Cortisol
IA-2 Albumin )$ ACTH

*In Red Available Soon


MAGLUMI 800
Chemiluminescence Immunoassay (CLIA) System
Technical Specifications

)ODVKFKHPLOXPLQHVFHQFHODEHO$%(,ZLWKKLJKVHQVLWLYLW\DQGORQJVWDELOLW\
5HDJHQW)HDWXUH Nano magnetic microbeads separation,fast and efficient

7KURXJKSXWXSWRWHVWVKRXU
0DLQ)HDWXUHV 24 hours ready to use
Time to first result: 17 minutes

Modes of Operation Random,Batch and STAT

Up to 40 sample tubes
Continuous loading,STAT available
Sample Loading Barcode reader recognition or analyzer auto numbered
LIS connection,auto read sample info
Refrigerated sample area with independent power supply

UHDJHQWVRQERDUG
Continuous loading
Reagent Loading 5),'UHDGLQJDOOLQIRRIUHDJHQW
Refrigerated reagent area

Ready-to-use, no pretreatment required


Including calibrators
Reagent Integral 5),'WDJVWRULQJDOOLQIRRIUHDJHQW
5),'WDJZLWKEXLOWLQPDVWHUFXUYH
2-point calibration to adjust master curve
Calibration stability: Max 4 weeks

Clot detection
Liquid level detection
2WKHU)HDWXUHV
Auto and optional ratio for high sample dilution
Constant 37°C incubation

Windows 7
Operation System '(//FRPSDWLEOH('XDOFRUH&38)
Color touch screen

Interconnection Bi-communication with LIS via ASTM protocol

,QSXW$&9+]0D[:
'LPHQVLRQV:HLJKW
'LPHQVLRQDQG:HLJKW  FPNJ

Shenzhen New Industries Biomedical Engineering Co., Ltd.(Snibe)