Specifications
Issue/Rev. 0.4 (11/00) Bulletin SS06030

The Smith MeterTM AccuLoad® III-S is a microprocessor-


based electronic instrument that can be programmed to be
either a single arm or dual arm device depending on the
firmware package that is installed in the unit. The single
arm unit is capable of loading a straight product, up to four
products as a sequential blender, or two products as a
ratio blender. The dual arm unit is capable of loading two
straight products, up to four products as a sequential
blender, and a straight product or two, four-product se-
quential blends, depending on I/O usage.

Features
One or Two Arm Operation
Straight Product and/or Sequential Blending or Ratio
Blending
Up to 50 Recipes Applications
User Configurable Inputs and Outputs
Block Valve Control and Feedback (Sequential Applications include batch loading of alcohols, gasolines,
Blending) antifreeze, lube oils, fuel oils, solvents, fertilizers, LPGs,
LNGs, and chemicals. The system is ideal for truck, barge,
Controls Additive Systems (Either via Pulse or
or rail car loading at loading racks, bulk plants, shipping
Communications)
docks, processing installations, and tank farms where
Four Communication Ports straight products, as well as blended products, must be
Programmable Pulse Outputs loaded.
Configurable Load Ticket/BOL Emulation Printing
Continuous Monitoring of Critical Functions Standard Features
Two-Way Data Communication; Built-in Communication
Analyzer
Straight Product (ALS1 or ALD1 Firmware)
Automatic Temperature and Pressure Compensation
and Density Correction The AccuLoad III is designed to handle either single arm,
straight product loading (ALS1) or dual arm, straight prod-
Meter Factor Calculation
uct loading (ALD1). Using the ALD1 dual arm firmware, both
Five Levels of Security products can be loaded simultaneously.
Automatic Adjustment of Final Trip Point
Sequential Blending (ALS1 or ALD1 Firmware)
Automatic Flow Control with Recovery
The AccuLoad III is designed to sequentially control the
API Tables From LPG to Crude Oil
loading of up to four petroleum or chemical products
GPA Tables TP-15 and TP-16 through a single loading arm (ALS1) or through two
Explosion-Proof loading arms (ALD1). The single arm software package
Programmable Languages/Messages (ALS1) controls the loading of up to four products se-
quentially through a single metering system and loading
LCD Graphics Display with Backlight arm. The dual arm software package (ALD1) controls
Turbine Meter Diagnostics the loading of up to four products sequentially through a
Boolean/Algebraic Processing single metering system and a straight product through a
Event Logging second metering system and loading arm. Another op-
tion using the ALD1 firmware is to have two, two product
Stand-Alone Operation sequential blending load arms each with up to four prod-
Grounding and Overfill Protection (Optional) ucts flowing through a metering postition and loading arm.

The Most Trusted Name In Measurement


Ratio Blending (ALS1 Firmware) the additive volume based on confirmation signals and a
The AccuLoad III is designed to control the blending of two programmable volume per cycle. The totalized volume will
petroleum or chemical products through a single loading print on the emulated load ticket printed on the shared
arm (ALS1) simultaneously. Both products flow through a printer output.
metering system, are co-mingled downstream of the me- For Smart additives, the firmware has also been designed
tering system and flow through a single loading arm into a with a Master/Slave type of communications, with the
transport. AccuLoad being the master and the Additive Injector Sys-
tem being the slave. The AccuLoad constantly interro-
Temperature Compensation gates the Additive Injector System for a change in status.
The temperature compensation option provides the cus- The AccuLoad can be operated with communications con-
tomer with the capability of compensating for the vari- trol over the Smart Additive Injecctor System or with com-
ance in temperature from a reference temperature. This munication/pulse control. When the AccuLoad has com-
option is used with an RTD input or a temperature trans- munication control over the Additive System, it will con-
ducer and, excluding the accuracy of the fluid tempera- stantly monitor the Additive System for its status, poll the
ture measurement, will exactly match the proper volume additive totals, and signal the system when to inject the
correction factor of ASTM-D-1250 (Sept. 1980) over the additive - all through the communications line.
fluid temperature range of -40°F to 572°F (-40°C to The AccuLoad communications package has also been
300°C). The following API tables can be programmed in designed with a pass-through communications mode.
the AccuLoad II: 5A, 5B, 5D, 6A, 6B, 6C, 6D, 23A, 23B, In this mode of operation the supervisory computer can
23D, 24, 24A, 24B, 24D, 53A, 53B, 53D, 54, 54A, 54B, talk to the Additive Injector System through the commu-
54C, and 54D. nication lines that have been run to the AccuLoad and
from the AccuLoad to the Additive Injector System(s).
Pressure Compensation
The pressure compensation option provides the cus- Dual Pulse Security
tomer with the capability of compensating the volume of This option provides continuous monitoring, error indi-
product delivered at varying pressures per API Tables cation alarm, and correction of the pulse transmission
11.2.1 and 11.2.2, using a 4-20 mA pressure transducer for each preset position per API Petroleum Measure-
input per preset position. This option also contains real- ment Standard, Chapter 5.5, Level A, and Institute of
time control functions for maintaining system pressures Petroleum Standard, IP 252/76, Part XIII, Section 1,
at the meter to a minimally-acceptable, user-definable Level A (PPS High-Security Pulse Transmitter is not
level (pressure transducer not included). This option is included). The PPS High-Security Transmitter provides
particularly useful for light products, such as LPG, where four signals: “A,” “A inverted,” “B,” and “B inverted.” The
the compressibility factor varies a great deal with differ- “A” and “B” signals are 90 electrical degrees out-of-
ent pressures. phase and used for dual-pulse security. The “A” and “A
inverted,” and “B” and“B inverted” signals are 180 elec-
Density Correction trical degrees out-of-phase and are used for transmitter
The density correction option provides the customer power sensing. If power sensing is not required, only “A”
with the capability of correcting the volume of product and “B” are used for dual-pulse security.
delivered at varying densities. This can be either a fre-
quency input or a 4-20 mA input. Automated Proving Mode
The AccuLoad III firmware provides an automated prov-
Metered Injectors, Piston Injectors and Smart ing mode of operation. When the automated proving
Additives mode is activated the AccuLoad will calculate the meter
AccuLoad III has been designed to provide maximum factor for a proving run based on information that is
flexibility when it comes to additive control. The unit is obtained during the prove. The operator can select the
capable of handling metered injectors, piston injectors flow rate and meter factor that is being proved through
and smart additives simultaneously. the keypad of the AccuLoad. After the prove is com-
The AccuLoad is capable of controlling two additive in- plete the operator enters the prover volume and prover
jector metered systems. (See Hardware Options for ad- temperature and the AccuLoad will calculate the new
ditional injector systems.) The AccuLoad controls the meter factor and the operator has the choice of down-
additive solenoids to precisely inject the additive into the loading it to the program or to ignore it. The AccuLoad
main product. It monitors the pulses of the additive meter also has the capability of providing an average meter
and controls the amount of additive, based on the incom- factor over a maximum of six proves. This feature
ing pulses from the additive meter and the main product allows the operator to prove the meter on all four prod-
meter. ucts, and four meter factors and associated flow rates
Additive monitoring and smart additives provide the ca- for each product without having to enter the program
mode for each product and meter factor.
pability for the AccuLoad to monitor the feedback from
the piston injectors of the additive products. The AccuLoad Boolean and Algebraic Processing
monitors the injector feedback switches for a change of
state and counts the errors and alarms if no change is The AccuLoad III provides the customer the flexibility to
set up inputs and outputs for tasks that are not standard in
detected within the cycle or a period of time, depending on
the unit. Through Boolean processing, relays can be turned
how the unit is programmed. The AccuLoad will totalize

Page 2 • SS06030 Issue/Rev. 0.4 (11/00)


on and off through equations and events set up by the Stability: 0.1°F (0.06°C)/year.
customer. For example, a relay is required to close at the Flow Totalizing: Within one pulse of input frequency.
first trip point of the load. This can be set up using Boolean
processing and does not require special software from Electrical Inputs
Smith. AC Instrument Power:
Algebraic processing is also an area that the customer Universal input 100 to 240 Vac, 58W maximum, 48 to
can use to do simple mathematical calculations that are 63 Hz. The AC circuitry is fuse-protected.
not in the unit. These calculations can then be used on Surge Current: 28A maximum for less than 0.1
the configurable reports for the current batch being run seconds.
by the unit.
Power Interruption Tolerance: Interruption of power
greater than .05 seconds (typical) will cause an or-
Hardware Options derly shut-down of the AccuLoad and the control valve
will be immediately signaled to close.
AccuLoad Interface Control Board Note: A constant voltage transformer (CVT) is recommended if the
available ac power is suspected not to comply with these
The AccuLoad Interface Control Board provides additional specifications.
flexibility to the AccuLoad's standard features. The op- Pulse Input:
tional AICB Board provides ten additional metered additive Type: High-speed, edge-triggered, optically isolated pulse
injector systems. With the optional AICB Board, the transmitter input. The input pulse must rise above V
AccuLoad III with ALS1 and ALD1 firmware has the capa- (high min.) for a period of time and then fall below V
bility of handling up to twelve metered injectors, twelve (low) to be recognized as a pulse by AccuLoad II.
meter inputs, twelve solenoid valve outputs, and twelve
additive pump outputs. The AICB Board is designed to V (High): 5 Vdc minimum to 28 Vdc maximum.
either be mounted in the AccuLoad III housing or in a V (Low): 1 Vdc maximum.
standalone enclosure. One of the AccuLoad III's four Input Impedance: 1.8 KΩ.
commmunication ports is required to communicate with
Pulse Resolution: 1 pulse/unit minimum, 9,999 pulses/
the AICB Board.
unit maximum.
Civacon Overfill and Grounding Board Frequency Range: 0 to 10.0 kHz.
The Civacon Overfill and Grounding Board provides an Response: Within one pulse to a step change in flow
automatic overfill protection system designed to protect rate.
and streamline the loading operation. When integrated into Mode: Single, dual, dual with power sensing, density.
the AccuLoad III, it provides an efficient and reliable moni-
Duty Cycle: 35/65 to 65/35 (on/off).
toring system that will eliminate the need for costly, explo-
sion-proof electrical boxes; automatically recognize an Temperature Probe:
overfill with either optic or thermistor sensors; automati- Type: four-wire, 100 Ω Platinum Resistance Tempera-
cally verify the grounding connection; automatically shut ture Detector (PRTD).
down and display a message on either an overfill or loss of Temperature Coefficient: @ 32°F: 0.00214 Ω/Ω/°F
grounding; and enable the master AccuLoad to communi- (0.00385 Ω/Ω/°C).
cate with the slave AccuLoads on that lane. The Civacon Temperature Range: -148°F to 572°F (-100°C to
Overfill and Grounding Board is designed to either be 300°C).
mounted in the AccuLoad III housing or in a standalone
enclosure. One of the AccuLoad III's four communication Offset: Temperature probe offset is program-adjust-
ports is required to communicate with the Overfill and able through the AccuLoad keypad in ±0.1 degree
Grounding Board. increments in the unit of temperature measurement
used.
Self calibrating: Lead length compensation that
Specifications (AccuLoad III) requires no resistance balancing of leads.
Analog (4-20 mA):
Accuracy Type: Two-wire, 4-20 mA current loop receiver, iso-
Calculated Accuracy: The gross at standard temperature lated from ground, programmable as to function.
to gross volume ratio, excluding the accuracy of fluid Span Adjustment: Program-adjustable through the
temperature measurement, will exactly match the proper AccuLoad keypad or communication in tenths of the
volume correction factor of ASTM-D-1250 (Sept. 1980) unit used.
over the fluid temperature range of -40°F to 572°F Input Burden: 50 Ω.
(-40°C to 300°C).
Accuracy: ±0.025% of range.
Temperature Measurement Accuracy: Fluid tempera-
ture is measured to within ±0.72°F (±0.4°C) over the Resolution: One part in 65,536.
fluid temperature range of -148°F to 572°F (-100°C to Voltage Drop: 2 Volts maximum.
300°C). Fluid temperature is measured to within ±0.45°F Sampling Rate: One sample/300 mSec minimum.
(±0.25°C) over the fluid temperature range of 32°F to
572°F (0°C to 300°C).

Issue/Rev. 0.4 (11/00) SS06030 • Page 3


Analog (1-5 Vdc): Analog (4-20 mA):
Type: Two-wire, 1-5 Vdc voltage loop receiver, iso- Type: Two-wire, 4-20 mA current loop transmitter, iso-
lated from ground, programmable as to function. lated from ground, programmable as to function.
Span Adjustment: Program-adjustable through the Span Adjustment: Program adjustable through the
AccuLoad keypad or communications in tenths of the AccuLoad keypad or through communications.
unit used. Accuracy: ±0.025% of range.
Input Burden: 1 m Ω. Resolution: One part in 65,536.
Accuracy: ±0.025% of range Voltage Burden: 4 volts maximum.
Resolution: One part in 65,536. Analog (1-5 Vdc):
Sampling Rate: One sample/300 mSec minimum. Type: Two-wire, 1-5 Vdc voltage loop transmitter, iso-
AC Inputs: lated from ground, programmable as to function.
Type: Optically-isolated, solid-state voltage sensor. Span Adjustment: Program adjustable through the
Input Voltage Range: 90 to 280 Vac. AccuLoad keypad or through communications.
Pickup Voltage: 90 Vac minimum. Accuracy: ±0.025% of range.
Drop-out Voltage: 30 Vac maximum. Resolution: One part in 65,536.
Current at Maximum Voltage: 20 mA maximum. Pulse Output:
Type: Optically-isolated solid state output. Pulser out-
Input Resistance: 44,000 Ω typical.
put units are program-selectable through the AccuLoad
DC Inputs: keypad or communications.
Type: Optically-isolated solid state voltage sensors Polarity: Programmable (normally open or normally
Input Voltage Range: 5 to 28 Vdc. closed).
Pickup Voltage: 5 Vdc minimum. Switch Blocking Voltage (Switch Off): 30 Vdc maximum.
Drop-out Voltage: Less than 1 volt. Load Current (Switch On): 10 mA with 0.6 volts drop.
Current at Maximum Voltage: 20 mA maximum. Frequency Range: 0 to 3000 Hz.
Input Level Duration: 120 mSec minimum. Duty Cycle: 50/50 (on/off).
Keypad: Environment
Type: Metal encapsulated, one-piece, sealed, no mov-
Ambient Operating Temperature
ing parts, piezoelectric design. Protected against the
-40oF to 140oF (-40oC to 60oC).
environment.
Humidity:
Display:
5 to 95% with condensation.
The Graphics Display is a 240 by 64 pixel graphic
Liquid Crystal Display (LCD) modules with LED back- Enclosure:
lighting. Explosion-proof (NEMA 7, Class I, Groups C and D)
and watertight (NEMA 4X), IP65.
Electrical Outputs Approvals
DC Power: UL/CUL
24 Vdc ±10%, 1 A maximum, short circuit protected. Class I, Division 1, Groups C & D; Class II, Groups
AC Outputs: E, F & G, UNL-UL Enclosure 4X, CNL-CSA Enclo-
Type: Optically-isolated, AC, solid-state relays. User- sure 4.
programmable as to function. Class I, Zone 1, Group IIB, IP65.
Load Voltage Range: 90 to 280 Vac (rms), 48 to 63 Hz. Class I, Zone 1, AEx d IIB T6, IP65.
Steady-State Load Current Range: 0.05A (rms) mini- UL/CUL File E23545 (N).
mum to 1.0A (rms) maximum into an inductive load.
CENELEC
Leakage Current at Maximum Voltage Rating: 5.2 mA EEx d IIB T6, IP65.
(rms) maximum @ 240 Vac.
DEMKO A/S Certificate No. 99.E.125227.
On-State Voltage Drop: 2 Vac at maximum load. Notes: AccuLoad III does not contain intrinsically-safe circuitry; there-
DC Outputs: fore, all peripheral equipment must be suitable for the area in which it is
Type: Optically-isolated solid state output. User-pro- installed.
grammable as to function. When supplied with the optional Civacon Overfill and Grounding Board
the AccuLoad III contains intrinsically safe circuitry. Only the equipment
Polarity: Programmable (normally open or normally connected to the circuit is intrinsically safe.
closed).*
Switch Blocking Voltage: 30 Vdc maximum. Weight: 50 lb (22.7 kg).
Load Current: 150 mA maximum with 0.6 volt drop.
Note: *Power-down normally open.

Page 4 • SS06030 Issue/Rev. 0.4 (11/00)


Electromagnetic Compatibility EIA-485 (1 dedicated, 2 programmable)
Type: Interfaceable with EIA-485 data communication stan-
Designed to meet the requirements of EMC directive dards.
89/336/EEC.
Typical Application: Communications with Product Man-
EN 50081-1: Generic Emission Standard, Residen- agement Automation Systems.
tial, Commercial and Light Industry.
Number of Units per Communication Line: Up to 32
EN 55022: Conducted (Class B) AccuLoads can be connected onto the same transmit
EN 55022: Radiated (Class B). and receive data lines.
IEC 61000-3-2: Limits for Harmonic Current Emissions.
IEC 61000-3-3: Limits of Voltage Fluctuations and
Flicker in L-V Supply Systems (Pend- Specifications (AICB Board - Optional)
ing).
EN-50082-2: Generic Immunity Standards, Indus- Electrical Inputs
trial Environment. DC Instrument Power:
IEC 1000-4-2: Electrostatic Discharge (Severity Level 4). 24 Vdc ±10%, 1 watt maximum
IEC 1000-4-3: Radiated, RF, Electromagnetic Field Pulse Input:
Immunity (Severity Level 3). Type: High-speed, edge-triggered, optically isolated,
IEC 1000-4-4: Electrical Fast Transient/Burst Immu- compatible with contact closure, open collector or volt-
nity Test (Severity Level 4). age sink/source pulse transmitter input. The input pulse
must rise above V (high min.) for a period of time and
IEC 1000-4-5: Surge Immunity Test (Class 3). then fall below V (low) to be recognized as a pulse.
IEC 1000-4-6: Immunity to Conducted Disturbances,
V (High): 10 Vdc minimum to 24 Vdc maximum.
Induced by RF Fields.
IEC 1000-4-8: Power Frequency Magnetic Field Im- V (Low): 8 Vdc maximum.
munity Test. Pulse Resolution: 1 pulse/unit minimum, 9,999 pulses/
IEC 1000-4-11: Voltage Disp, Short Interruptions and unit maximum.
Voltage Variations Immunity Tests. Frequency Range: 0 to 5 kHz.
Response: Within one pulse to a step change in flow
rate.
Communications
Minimum Pulse Width: 50 uS.
General Electrical Outputs
Number of Ports: Four. AC Outputs:
Configuration: Multi-drop network. Up to 32 AccuLoad Type: Optically-isolated, AC, solid-state relays. User-
IIIs can be connected onto the same transmit and re- programmable by the host as to function.
ceive data lines. Load Voltage Range: 90 to 275 Vac (rms), 48 to 63 Hz.
Data Rate: Keypad-selectable to asynchronous data rates Steady-State Load Current Range: 0.05A (rms) mini-
of 1,200, 2,400, 3,600, 4,800, 7,200, 9,600, 19,200, or mum to 0.5A (rms) maximum into an inductive load.
38,400 bps.
Leakage Current at Maximum Voltage Rating: 0.1mA
Data Format: Programmable one start bit, programmable (rms) maximum at 240 Vac.
seven or eight data bits - even, odd, or no parity, one
stop bit. On-State Voltage Drop: 1.5 Vac at maximum load.
Line Protocol: Half-duplex, full-duplex, no character echo. Environment
Data Structure: ASCII character-oriented, modeled after Ambient Operating Temperature
ISO Standard 1155. -40oF to 140oF (-40oC to 60oC).
Protocol: Smith ASCII LRC, Smith ASCII CR, Smith ASCII Humidity:
binary, Modbus. 5 to 95% with condensation.
AccuLoad II Style: Terminal Mode, Minicomputer Mode. Remote Enclosure:
Explosion-proof (NEMA 7, Class I, Groups C and D)
EIA-232 (1 dedicated, 2 programmable) and watertight (NEMA 4X), IP65
Type: Interfaceable with EIA-232 data communication Approvals
standards. Data transmitters are tri-state design. UL/CUL:
Typical Applications: Product receipt ticket printing (used Class I, Division 1, Groups C and D; Class II, Groups
with a stand-alone ASCII printer or as a backup in the E, F and G, UNL-UL Enclosure 4X, CNL-CSA Enclo-
standby mode with automation for BOL emulation) or sure 4.
communications with Product Management Automation Class I, Zone 1, AEx d IIB T6, IP65.
Systems. Up to 16 AccuLoads can be connected onto the CENELEC (DEMKO):
same transmit and receive data lines. EEx d IIB T6, IP65
Class I, Zone 1, Ex d IIB T6.

Issue/Rev. 0.4 (11/00) SS06030 • Page 5


Specifications Ground Relay Bypass Switch
(Civacon Microrack® Monitor) Type: No contact
Voltage: 120 Vac/24 Vdc
Electrical Inputs Current: 5A
DC Instrument Power: Overfill Bypass Switch
24 Vdc ±10%, 36 W maximum Type: No contact
Bypass Switch Voltage: 120 Vac/24 Vdc
No contact, 12 Vdc 50mA Current: 5A
Sensor Inputs Environment
Thermistor
Ambient Operating Temperature
200/2000 W -40°F to 140°F (-40°C to 60°C)
9 Vdc 1.8 W maximum Humidity
Optic 5 to 95% with condensation
5-wire and 2-wire Quickstart® Remote Enclosure
9 Vdc 1.8 W maximum Explosion-proof (NEMA 7, Class I, Groups C and D)
Electric Outputs and watertight (NEMA 4X), IP65
Overfill Relay Contact Approvals
Type: 1 form C (SPDT) UL/CUL (Pending):
Class I, Division I, Groups C and D; Class II, Groups E,
Voltage: 20 Vac/24 Vdc F, and G, UNL-UL Enclosure 4X, CNL-CSA Enclosure
Current: 5A 4.
Ground Relay Contact Class I, Zone I, AEx d [ia] IIB T6, IP65
Type: 1 form C (SPDT) CENELEC (DEMKO) (Pending):
Voltage: 120 Vac/24 Vdc EEx d [ia] IIB T6, IP65
Current: 5A Class I, Zone 1, Ex d [ia] IIB T6.

Page 6 • SS06030 Issue/Rev. 0.4 (11/00)


Modeling (AccuLoad III) 1

ALIII ⎯ S ⎯ XP ⎯ ALS1 ⎯ A00000 ⎯

Hardware Option
Hardware Model Designation Blank - None
ALIII - S A - AICB Board
C - Civacon Grounding Board

Analog Modules2
DIGIT 1 - # of RTDs
Housing DIGIT 2 - # of 4-20 mA inputs
DIGIT 3 - # of 4-20 mA outputs
XP - UL/CUL, EEx d IIB, IP65
DEMKO A/S DIGIT 4 - # of 5 Vdc inputs
DIGIT 5 - # of 1-5 Vdc outputs

Firmware
ALS1 - Single arm, straight product,
sequential and ratio blending
ALD1 - Dual arm, straight product,
sequential blending

Modeling (AICB/Civacon Board Remote Mount)

REM - XP - A

Model Designation Hardware Option

A = AICB Board
C = Civacon Board

Housing

XP - Explosion Proof

1 A complete model number is required when ordering the AccuLoad III.


2 Maximum of 6 Analog Modules.

Issue/Rev. 0.4 (11/00) SS06030 • Page 7


Input/Output Worksheet3
This worksheet is provided to aid in determining the number of inputs and outputs required for a given application. Circle
the number of inputs/outputs required, add the circled numbers together, and check the answer making sure that it does
not exceed the totals listed below.

DC Inputs Circle Number Required AC Outputs Circle Number Required


Block Valve Feedback 0 1 2 3 4 5 6 Block Valves 0 1 2 3 4 5 6 7 8
Permissives 0 1 2 Pump 0 1 2
Security 0 1 2 Upstream Solenoid 0 1 2
First/Second High Flow 0 1 Downstream Solenoid 0 1 2
Remote Start 0 1 Alarm Relay 0 1 2
Remote Stop 0 1 Additive Pump 0 1 2 3 4 5 6 7 8 9 10 11
Transaction Reset 0 1 Piston Injector 0 1 2 3 4 5 6 7 8 9 10 11
Piston Injector Feedback 0 1 2 3 4 5 6 Metered Injector Solenoid 0 1 2
General Purpose 0 1 2 3 4 5 6 General Purpose Output 0 1 2 3 4 5 6 7 8 9 10 11
Total 6 or less Total 11 or less

AC Inputs Pulse Inputs


Block Valve Feedback 0 1 2 3 4 5 Product Meter
Permissives 0 1 2 Single Pulse 0 1 2
Security 0 1 2 Dual Pulse/Power Sensing 0 1 2 3 4 5 6
First/Second High Flow 0 1 Additive Meter 0 1 2
Remote Start 0 1 Densitometer 0 1
Remote Stop 0 1 Total 6 or less
Transaction Reset 0 1
Piston Injector Feedback 0 1 2 3 4 5
General Purpose 0 1 2 3 4 5
Total 5 or less

DC Outputs Analog Inputs/Outputs (Optional)


Block Valves 0 1 2 3 4-20 mA Inputs 0 1 2 3 4 5 6
Pump 0 1 2 4-20 mA Output 0 12 3 4
Upstream Solenoid 0 1 2 1-5 Vdc Input 0 1 2 3 4 5 6
Downstream Solenoid 0 1 2 1-5 Vdc Output 0 1 2 3 4
Alarm Relay 0 1 2 RTD 0 1 2
Additive Pump 0 1 2 3 Total 6 or less
Piston Injector 0 1 2 3
Metered Injector Solenoid 0 1 2
General Purpose Output 0 1 2 3
Total 3 or less

Pulse Outputs Communication Ports


Pulse Outputs 0 1 2 RS-232 0 1 2 3
Total 2 or less RS-485 0 1 2 3
Total 4 or less

Optional - AICB Board


Pulse Inputs AC Outputs

Additive Meter 0 1 2 3 4 5 6 7 8 9 10 Additive Pump 0 1 2 3 4 5 6 7 8 9 10


Total 10 or less Metered Injector Solenoid 0 1 2 3 4 5 6 7 8 9 10
Total 20 or less

3 This worksheet is provided to ensure the number of Inputs/Outputs required for the application are available. Totals indicate the number available in
the AccuLoad III and are included except for the Analog Inputs/Outputs which are optional.

Page 8 • SS06030 Issue/Rev. 0.4 (11/00)


2

A12

Issue/Rev. 0.4 (11/00)


Arm 1
Flow Rate Switch

A1 through
A6
A7 through
A1 through A12
A12
Smart Additives
Valve Stem Switch VSW (S)
Digital Control Valve DCS (S)
Density Transmitter (S) DT
Pressure (S) PT
Temperature Probe (S) TE
Pump (S) P
Flow Transmitter (S) FT
Security Switch 1
Security Switch 2

Arm 2
Flow Rate Switch

A12

SS06030 • Page 9
Smart Computer
Additive AccuLoad III

Printer

Pump Digital
Control
Strainer Valve

Additive
Meter

Figure 1 – Single Arm/Single Product

Computer TAS
Control
Power

Pump AccuLoad III


Output BOL Printer
Control
Relay

BV Printer
Feedback
Typ. (4)

Block Valve1

CK 1
Pump 1
Block Valve 2

Pump 2 CK 2

Block Valve 3 PRIME Digital


Control
Strainer Meter
CK 3 Valve
Pump 3 Typ. (Up to 12)
Block Valve 4
Meter Pulse
Pump 4 CK 4 Solenoid
AccuTroller (1 Unit 6 Additives, 2x = 12)

Mono
Block

Figure 2 – Single Arm/Four Product Sequential Blender

Page 10 • SS06030 Issue/Rev. 0.4 (11/00)


Computer TAS

Pump AccuLoad III

Control Output BOL Printer


Relay

Printer

Pump 1

Pump 2 PRIME Digital


Meter Control
Strainer
Valve

Meter Pulse
Mono
Block Solenoid

AccuTroller (1 Unit 6 Additives, 2x = 12)


Typ. (6) each Arm

Figure 3 – Single Arm/2 Product Ratio Blender

Smart Computer
Additive AccuLoad III

Printer

Pump Digital
Control
Strainer Valve

Additive
Meter

Figure 4 – Dual Arm/Dual Product

Issue/Rev. 0.4 (11/00) SS06030 • Page 11


Computer TAS
Control
Power

Pump AccuLoad III

Control Output BOL Printer


Relay

BV Printer
Feedback
Typ. of 3

Block Valve1

CK 1
Pump 1
Block Valve 2 PRIME Digital
Meter Control
CK 2 Strainer
Valve
Pump 2 Typ. (Up to 12)
Block Valve 3
Meter Pulse

CK 3 Solenoid
Pump 3 AccuTroller (1 Unit 6 Additives, 2x = 12)
Mono
Block

Pump 4

Figure 5 – Dual Arm/Three Product Sequential Blender, One Straight Product

Control Computer TAS


Power

Pump AccuLoad III

Control Output BOL Printer


Relay

BV Printer
Feedback
Typ. of 2

Block Valve1

CK 1
Pump 1
Block Valve 2 PRIME Digital
Meter Control
CK 2 Strainer
Valve
Pump 2 Typ. (Up to 6)
Meter Pulse
Solenoid
AccuTroller
Mono (1 Unit 6 Additives, 2x = 12)
Block
Block Valve 3

CK 3
Pump 3
Block Valve 4

CK 4
Pump 4

Figure 6 – Dual Arm/Two Product Sequential Blender

Page 12 • SS06030 Issue/Rev. 0.4 (11/00)


1 - 11.5" NPT
2 Places

8.0"
(203)

2.69"
(68)

7.5"
(190)
14.2"
8.5"
(361)
(216)
4.2"
(107)

3.00"
(76)
11.8"
6.00" (300)
(152)

5.00"
Back View (127)
2.5"
(64)

1.25" - 11.5" NPT for


Conduit Entrance
Typical 3 Places

0.375" - 16 UNC-2B x 0.56" Deep


Typical 8 Places
3.56" 2.87"
(Bottom and Back Mounting)
(90) (73)

1.4"
(36)

4.2"
(107)
8.5"
(216)

Figure 7 — Explosion-Proof Housing

Issue/Rev. 0.4 (11/00) SS06030 • Page 13


2.50"
(64)

6.50"
(165)

13.4"
(340)

10.4"
(264)

2.00"
(51)
6.2"
(157)

1.50" 1.50"
(38) (38)
1.00" - 11.5" NPT 1.25" - 11.5" NPT
Conduit Entrance Conduit Entrances
9.75" Typical 2 Places
(248)

Figure 8 - Remote Housing (Optional AICB and Civacon)

Page 14 • SS06030 Issue/Rev. 0.4 (11/00)


Revisions included in SS06030 Issue/Rev. 0.4 (11/00):
Page 4: Added Note
Page 5: Changed Load Voltage Range from 90 to 280 Vac to 90 to 275 Vac
Page 7: Added Hardware to Model Designation, removed including RTD Standard from Note 2.
Page 14: Added Conduit Entrance.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the
specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are
no longer in effect.

Headquarters:
1803 Gears Road, Houston, TX 77067 USA, Phone: 281/260-2190, Fax: 281/260-2191
Gas Measurement Products: Liquid Measurement Products:
Houston, TX USA Phone 281/260-2190 Erie, PA USA Phone 814/898-5000 Beijing, China Phone (86) 10/6500-2251
Thetford, England Phone (44) 1842-82-2900 Los Angeles, CA USA Phone 661/702-8660 Singapore Phone (65) 6861-3011
Kongsberg, Norway Phone (47) 32/286-700 Slough, England Phone (44) 1753-57-1515 Chennai, India Phone (91) 44/450-4400
Buenos Aires, Argentina Phone 54 (11) 4312-4736 Ellerbek, Germany Phone (49) 4101-3040
Integrated Measurement Systems: Barcelona, Spain Phone (34) 93/201-0989
Corpus Christi, TX USA Phone 361/289-3400 Moscow, Russia Phone (7) 495/564-8705
Kongsberg, Norway Phone (47) 32/286-700 Melbourne, Australia Phone (61) 3/9807-2818
San Juan, Puerto Rico Phone 787/274-3760
United Arab Emirates, Dubai Phone 971 +4/331-3646
Visit our website at www.fmctechnologies.com
Printed in U.S.A. © 9/99 FMC Technologies Measurement Solutions, Inc. All rights reserved. SS06030 Issue/Rev. 0.4 (11/00)