Allowable bending moment - Axial Load Graph PC Pile φ300

PC Pile φ300
45
φ300 PC Pile
Allowable stresses of concrete (N/mm2)
C Type A Type B TypeC
40 B
A Compression (Normal conditions) 22.5 22.5 22.5
(Seismic conditions) 30.0 30.0 30.0
Tension (Normal conditions) 0.0 0.0 0.0
35 (Seismic conditions) -3.6 -3.6 -3.6
Allowable bending moment Ma (kN・m)

30
Normal conditions
C B A Seismic conditions
25

20

15

10

0
-1000 -500 0 500 1000 1500

Axial Load N (kN)


Allowable bending moment - Axial Load Graph PC Pile φ350
PC Pile φ350
70
φ350 PC Pile
Allowable stresses of concrete (N/mm2)
Type A Type B TypeC
C
B Compression (Normal conditions) 22.5 22.5 22.5
A
60 (Seismic conditions) 30.0 30.0 30.0
Tension (Normal conditions) 0.0 0.0 0.0
(Seismic conditions) -3.6 -3.6 -3.6

50
Allowable bending moment Ma (kN・m)

Normal conditions
B Seismic conditions
40 C A

30

20

10

0
-1000 -500 0 500 1000 1500 2000

Axial Load N (kN)


Allowable bending moment - Axial Load Graph PC Pile φ400
PC Pile φ400
100
φ400 PC Pile
C
B Allowable stresses of concrete (N/mm2)
A
90 Type A Type B TypeC
Compression (Normal conditions) 22.5 22.5 22.5
(Seismic conditions) 30.0 30.0 30.0
80 Tension (Normal conditions) 0.0 0.0 0.0
(Seismic conditions) -3.6 -3.6 -3.6
Allowable bending moment Ma (kN・m)

70

C B A Normal conditions
60
Seismic conditions

50

40

30

20

10

0
-1500 -1000 -500 0 500 1000 1500 2000 2500

Axial Load N (kN)


Allowable bending moment - Axial Load Graph PC Pile φ450
PC Pile φ450
140 φ450 PC Pile
Allowable stresses of concrete (N/mm2)
C B Type A Type B TypeC
A Compression (Normal conditions) 22.5 22.5 22.5
120 (Seismic conditions) 30.0 30.0 30.0
Tension (Normal conditions) 0.0 0.0 0.0
(Seismic conditions) -3.6 -3.6 -3.6

100
Allowable bending moment Ma (kN・m)

Normal conditions
C B
A Seismic conditions
80

60

40

20

0
-2000 -1500 -1000 -500 0 500 1000 1500 2000 2500 3000

Axial Load N (kN)


Allowable bending moment - Axial Load Graph PC Pile φ500
PC Pile φ500
200 φ500 PC Pile
Allowable stresses of concrete (N/mm2)
Type A Type B TypeC
180 C
B Compression (Normal conditions) 22.5 22.5 22.5
A
(Seismic conditions) 30.0 30.0 30.0
Tension (Normal conditions) 0.0 0.0 0.0
160 (Seismic conditions) -3.6 -3.6 -3.6

140
Allowable bending moment Ma (kN・m)

Normal conditions
120 C B Seismic conditions
A

100

80

60

40

20

0
-2000 -1000 0 1000 2000 3000 4000

Axial Load N (kN)


Allowable bending moment - Axial Load Graph PC Pile φ600
PC Pile φ600
350
φ600 PC Pile
Allowable stresses of concrete (N/mm2)
Type A Type B TypeC
C Compression (Normal conditions) 22.5 22.5 22.5
300 B
A (Seismic conditions) 30.0 30.0 30.0
Tension (Normal conditions) 0.0 0.0 0.0
(Seismic conditions) -3.6 -3.6 -3.6

250
Allowable bending moment Ma (kN・m)

Normal conditions

200 C B Seismic conditions


A

150

100

50

0
-3000 -2000 -1000 0 1000 2000 3000 4000 5000

Axial Load N (kN)